Smart inadvertent islanding detection employing p-type PMU for an active distribution network

被引:18
|
作者
Dutta, Soham [1 ]
Sadhu, Pradip Kumar [1 ]
Reddy, Maddikara Jaya Bharata [2 ]
Mohanta, Dusmanta Kumar [3 ]
机构
[1] IIT ISM, Dept EE, Dhanbad 826004, JH, India
[2] NIT, Dept EEE, Tiruchirappalli 620015, TN, India
[3] BIT, Dept EEE, Ranchi 835215, JH, India
关键词
phasor measurement; distributed power generation; discrete Fourier transforms; relay protection; power distribution protection; power generation protection; signal detection; smart power grids; smart inadvertent islanding detection; p-type PMU; active distribution network; protection type microphasor measurement unit; situational awareness; distributed generation; current phasors; voltage phasors; discrete Fourier transform; Fortescue transform; sequence components; absolute angle difference; zero components; positive components; relay; measuring equipment; smart-grid paradigm; distribution systems; SYNCHRONIZED PHASOR; VOLTAGE UNBALANCE; SYSTEM; GENERATIONS; STORAGE;
D O I
10.1049/iet-gtd.2018.5805
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the smart-grid paradigm, since distribution systems are controlled by various independent operators, it becomes inevitable for all dispatchers to have a wide-area view of the network for situational awareness and protection. This visualisation is accomplished with the aid of protection (p) type micro-phasor measurement unit (PMU) installed at the bus of the respective distributed generation (DG). One of the pressing issues with DG's is the concern of inadvertent islanding that disrupts orderly reconnection besides posing hazards to utility workers. In view of this, this study proposes a real-time inadvertent islanding detection by PMU. The voltage and current phasors obtained from these PMUs by discrete Fourier transform are further processed by Fortescue transform to compute the angle of sequence components. The absolute angle difference between positive and zero components is used to initiate signal for accomplishing intelligent islanding under islanded condition. The simulation results prove the method to be robust, computationally efficient, non-detection zone free and feasible. Most significantly, as measuring equipment and relay are already present in p type PMU, therefore unlike other detection methods, no extra arrangements are required in this method making it economically viable and easy to implement.
引用
收藏
页码:4615 / 4625
页数:11
相关论文
共 50 条
  • [21] Synchronized Phasors Monitoring During the Islanding Maneuver of an Active Distribution Network
    Borghetti, Alberto
    Nucci, Carlo Alberto
    Paolone, Mario
    Ciappi, Gaetano
    Solari, Aurelio
    IEEE TRANSACTIONS ON SMART GRID, 2011, 2 (01) : 82 - 91
  • [22] Topology and Parameter Identification of Distribution Network Using Smart Meter and μPMU Measurements
    Srinivas, Vedantham Lakshmi
    Wu, Jianzhong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [23] PMU Based Online Dynamic Characteristic Assessment Method of Smart Distribution Network
    Zheng X.
    He W.
    Wang S.
    Liu J.
    Li C.
    Fang C.
    Zhou Y.
    Zhu Y.
    Li Y.
    Dianwang Jishu/Power System Technology, 2019, 43 (09): : 3210 - 3217
  • [24] THz Detection in p-Type FETs
    Zaborowskil, Michal
    Marczewski, Jacek
    Tomaszewski, Daniel
    Zagrajek, Przemyslaw
    2023 48TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, IRMMW-THZ, 2023,
  • [25] A Novel Method for Islanding in Active Distribution Network Considering Distributed Generation
    Wang, Jun
    Wang, Xinran
    Di, Bart
    Sun, Chao
    Zheng, Wei
    Journal of Power Technologies, 2021, 101 (01): : 11 - 20
  • [26] Active Islanding Detection Method Using Wavelet Fuzzy Neural Network
    Lin, Faa-Jeng
    Tan, Kuang-Hsiung
    Chiu, Jian-Hsing
    2012 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ-IEEE), 2012,
  • [27] Ambipolar organic light-emitting transistors employing heterojunctions of n-type and p-type materials as the active layer
    Capelli, R.
    Dinelli, F.
    Loi, M. A.
    Murgia, M.
    Zamboni, R.
    Muccini, M.
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2006, 18 (33) : S2127 - S2138
  • [28] A New Method of Unintentional Islanding Detection for Distribution Network with Synchronous DG
    Abd el-Ghany, Hossam A.
    ElSadd, Mahmoud A.
    Ahmed, Eman S.
    2018 TWENTIETH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2018, : 1046 - 1052
  • [29] An islanding detection strategy for distribution network connected with hybrid DG resources
    Laghari, J. A.
    Mokhlis, H.
    Karimi, M.
    Bakar, A. H. A.
    Mohamad, Hasmaini
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 45 : 662 - 676
  • [30] AoI research on PMU cloud side Cooperative System of active distribution network
    Lin Wenqin
    Xia Bingsen
    Tang Yuanchun
    Zhang Tiantian
    Qi Yincheng
    ENERGY REPORTS, 2022, 8 : 677 - 686