Multimodality Imaging in Transcatheter Aortic Valve Implantation and Post-Procedural Aortic Regurgitation Comparison Among Cardiovascular Magnetic Resonance, Cardiac Computed Tomography, and Echocardiography

被引:147
|
作者
Jabbour, Andrew [2 ]
Ismail, Tevfik F. [2 ]
Moat, Neil [2 ]
Gulati, Ankur [2 ]
Roussin, Isabelle [2 ]
Alpendurada, Francisco [2 ]
Park, Bradley [2 ]
Okoroafor, Francois [2 ]
Asgar, Anita [2 ]
Barker, Sarah [2 ]
Davies, Simon [2 ]
Prasad, Sanjay K. [2 ]
Rubens, Michael [2 ]
Mohiaddin, Raad H. [1 ,2 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, Royal Brompton Hosp, Cardiovasc Magnet Resonance Unit, London SW3 6NP, England
[2] Royal Brompton & Harefield NHS Fdn Trust, London, England
基金
英国医学研究理事会;
关键词
aortic stenosis; cardiac computed tomography; cardiovascular magnetic resonance; transcatheter aortic valve; implantation; transthoracic echocardiography; STENOSIS; REPLACEMENT; ANNULUS; RECOMMENDATIONS; PROSTHESIS; SURGERY; ROOT;
D O I
10.1016/j.jacc.2011.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The purpose of this study was to determine imaging predictors of aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) and the agreement and reproducibility of cardiovascular magnetic resonance (CMR), cardiac computed tomography (CCT), and transthoracic echocardiography (TTE) in aortic root assessment. Background The optimal imaging strategy for planning TAVI is unclear with a paucity of comparative multimodality imaging data. The association between aortic root morphology and outcomes after TAVI also remains incompletely understood. Methods A total of 202 consecutive patients assessed by CMR, CCT, and TTE for TAVI were studied. Agreement and variability among and within imaging modalities was assessed by Bland-Altman analysis. Postoperative AR was assessed by TTE. Results Of the 202 patients undergoing TAVI assessment with both CMR and TTE, 133 also underwent CCT. Close agreement was observed between CMR and CCT in dimensions of the aortic annulus (bias, -0.4 mm; 95% limits of agreement: -5.7 to 5.0 mm), and similarly for sinus of Valsalva, sinotubular junction, and ascending aortic measures. Agreement between TTE-derived measures and either CMR or CCT was less precise. Intraobserver and interobserver variability were lowest with CMR. The presence and severity of AR after TAVI were associated with larger aortic valve annulus measurements by both CMR (p = 0.03) and CCT (p = 0.04) but not TTE-derived measures (p = 0.10). Neither CCT nor CMR measures of annulus eccentricity, however, predicted AR after TAVI (p = 0.33 and p = 0.78, respectively). Conclusions In patients undergoing imaging assessment for TAVI, the presence and severity of AR after TAVI were associated with larger aortic annulus measurements by both CMR and CCT, but not TTE. Both CMR and CCT provide highly reproducible information in the assessment of patients undergoing TAVI. (J Am Coll Cardiol 2011;58:2165-73) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:2165 / 2173
页数:9
相关论文
共 50 条
  • [31] Quantification of paravalvular regurgitation after transcatheter aortic valve implantation by 3D transthoracic echocardiography in comparison with cardiac magnetic resonance imaging
    Altiok, E.
    Frick, M.
    Meyer, C.
    Al Ateah, G.
    Napp, A.
    Almalla, M.
    Aktug, O.
    Becker, M.
    Marx, N.
    Hoffmann, R.
    EUROPEAN HEART JOURNAL, 2013, 34 : 398 - 399
  • [32] Sex-differences in Post-procedural Aortic Regurgitation and Mid-term Mortality after Transcatheter Aortic Valve Implantation
    Ferrante, Giuseppe
    Pagnotta, Paolo
    Petronio, Anna Sonia
    Bedogni, Francesco
    Brambilla, Nedy
    Fiorina, Claudia
    Giannini, Cristina
    Mennuni, Marco G.
    De Marco, Federico
    Klugmann, Silvio
    Ettori, Federica
    Presbitero, Patrizia
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B230 - B230
  • [33] CT predictors of post-procedural aortic regurgitation in patients referred for transcatheter aortic valve implantation: a prospective analysis of 105 patients
    Marwan, M.
    Achenbach, S.
    Ensminger, S.
    Feyrer, R.
    Ludwig, J.
    Gauss, S.
    Schuhbaeck, A.
    Weyand, M.
    Daniel, W. G.
    Arnold, M.
    EUROPEAN HEART JOURNAL, 2011, 32 : 1011 - 1011
  • [34] CT PREDICTORS OF POST-PROCEDURAL AORTIC REGURGITATION IN PATIENTS REFERRED FOR TRANSCATHETER AORTIC VALVE IMPLANTATION: A PROSPECTIVE ANALYSIS OF 105 PATIENTS
    Marwan, Mohamed
    Arnold, Martin
    Ensminger, Stefan
    Pflederer, Tobias
    Ropers, Dieter
    Ludwig, Josef
    Weyand, Michael
    Daniel, Werner
    Achenbach, Stephan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1197 - E1197
  • [35] Hemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using cardiovascular magnetic resonance
    Sherif, M.
    Abdel-Wahab, M.
    Beurich, H. -W.
    Stoecker, B.
    Zachow, D.
    Geist, V.
    Toelg, R.
    Richardt, G.
    EUROPEAN HEART JOURNAL, 2010, 31 : 144 - 144
  • [36] Haemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using cardiovascular magnetic resonance
    Sherif, Mohammad A.
    Abdel-Wahab, Mohamed
    Beurich, Hans-Wilko
    Stoecker, Bjoern
    Zachow, Dirk
    Geist, Volker
    Toelg, Ralph
    Richardt, Gert
    EUROINTERVENTION, 2011, 7 (01) : 57 - 63
  • [37] Hemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using the dimensionless aortic regurgitation index compared to cardiac magnetic resonance imaging
    Merten, C.
    El-Mawardy, M.
    Beurich, H.
    Abdel-Wahab, M.
    Zachow, D.
    Richardt, G.
    EUROPEAN HEART JOURNAL, 2014, 35 : 424 - 424
  • [38] Multimodality Imaging of the Neglected Valve: Role of Echocardiography, Cardiac Magnetic Resonance and Cardiac Computed Tomography in Pulmonary Stenosis and Regurgitation
    Costantini, Pietro
    Perone, Francesco
    Siani, Agnese
    Groenhoff, Leon
    Muscogiuri, Giuseppe
    Sironi, Sandro
    Marra, Paolo
    Carriero, Serena
    Pavon, Anna Giulia
    Guglielmo, Marco
    JOURNAL OF IMAGING, 2022, 8 (10)
  • [40] Accuracy of aortic root annulus assessment with cardiac magnetic resonance in patients referred for transcatheter aortic valve implantation: a comparison with multidetector computed tomography
    Pontone, G.
    Andreini, D.
    Bertella, E.
    Mushtaq, S.
    Gripari, P.
    Cortinovis, S.
    Loguercio, M.
    Baggiano, A.
    Conte, E.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 32 - 32