Effect of CT image compression on computer-assisted lung nodule volume measurement

被引:21
|
作者
Ko, LP [1 ]
Chang, J [1 ]
Bomsztyk, E [1 ]
Babb, JS [1 ]
Naidich, DP [1 ]
Rusinek, H [1 ]
机构
[1] NYU, Med Ctr, Dept Radiol, Thorac Imaging Sect, New York, NY 10016 USA
关键词
D O I
10.1148/radiol.2371041079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the effect of two-dimensional wavelet-based computed tomographic (CT) image compression according to the Joint Photographic Experts Group (JPEG) 2000 standard on computer-assisted assessment of nodule volume. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the research board at the authors' institution; patients' informed consent was not required. Fifty-one nodules in 23 patients (seven men, 16 women; mean age, 59 years; age range, 39-75 years) were selected on low-dose CT scans that were compressed to levels of 10:1, 20:1, 30:1, and 40:1 by using a two-dimensional JPEG 2000 wavelet-based image compression method. Nodules were classified according to size (<= 5 mm or > 5 mm in diameter), location (central, peripheral, or abutting pleura or fissures), and attenuation (solid, calcified, or subsolid). Regions of interest were placed on the original images and transposed onto compressed images. Nodule volumes on original (noncompressed) and compressed images were measured by using a computer-assisted method. A mixed-model analysis of variance was conducted for statistical evaluation. RESULTS: Nodule volumes averaged 388.1 mm(3) (range, 34-3474 mm(3)). There were three calcified, 33 solid noncalcified, and 15 subsolid nodules (13 with ground-glass attenuation). Average volume decreased with increasing compression level, to 383 mm(3) (10:1), 370 mm(3) (20:1), 360 mm(3) (30:1), and 354 mm(3) (40:1). No significant difference was identified between measurements obtained on original images and those compressed to a level of 10:1. Significant differences were noted, however, between original images and those compressed to a level of 20:1 or greater (P <.05). Compression level significantly interacted with nodule size, location, and attenuation (P <.001). The effect of compression was greater for nodules with ground-glass attenuation than for those with higher attenuation values. The difference in mean volumes between original images and those compressed to a level of 20:1 was 34.9 mm(3) for nodules with ground-glass attenuation, compared with 8.3 mm(3) for higher-attenuation nodules, a 4.2-fold difference. CONCLUSION: Nodule volumes measured on images compressed to a level of 20:1 differed significantly from those measured on noncompressed images, especially for nodules with ground-glass attenuation. This difference could affect the assessment of nodule change in size as measured with computer-assisted methods. (c) RSNA, 2005.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 50 条
  • [41] Computer-assisted measurement of skin test wheals
    Smith, PH
    Condemi, JJ
    Baum, J
    Rosier, RN
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1996, 97 (01) : 102 - 102
  • [42] COMPUTER-ASSISTED MEASUREMENT OF LIVER IMAGE INHOMOGENEITY BY TEXTURE INDEX T2
    EIKMAN, EA
    JAIN, VK
    MACK, GA
    MADDEN, JA
    FLOWER, DL
    WITENHAFER, SR
    JOURNAL OF NUCLEAR MEDICINE, 1979, 20 (06) : 665 - 665
  • [43] MEASUREMENT OF HUMAN POLYMORPHONUCLEAR LEUKOCYTE CHEMOTAXIS USING COMPUTER-ASSISTED IMAGE-ANALYSIS
    DONOVAN, RM
    KIM, Y
    GOLDSTEIN, E
    CHEUNG, AT
    MILLER, ME
    LIPPERT, W
    CHANG, D
    CLINICAL RESEARCH, 1986, 34 (01): : A46 - A46
  • [44] Volume Visualization for Improving CT Lung Nodule Detection
    Huang, Adam
    Lee, Chung-Wei
    Yang, Chung-Yi
    Liu, Hon-Man
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 1035 - 1038
  • [45] CT slice thickness and measured lung nodule volume
    Winer-Muram, HT
    Jennings, SG
    McGarry, RC
    RADIOLOGY, 2001, 221 : 410 - 410
  • [46] Computer aided lung nodule detection on CT data
    Jia, Tong
    Wu, Cheng Dong
    Wei, Ying
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE, PTS 1-4, 2011, 44-47 : 3492 - 3496
  • [47] Computer-assisted delineation of hematoma from CT volume using autoencoder and Chan Vese model
    Nag, Manas Kumar
    Chatterjee, Saunak
    Sadhu, Anup Kumar
    Chatterjee, Jyotirmoy
    Ghosh, Nirmalya
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (02) : 259 - 269
  • [48] Efficiency and reproducibility of computer-assisted fractional limb volume
    Mack, Lauren M.
    Kim, Sung Yoon
    Lee, Sungmin
    Sangi-Haghpeykar, Haleh
    Lee, Wesley
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2016, 214 (01) : S301 - S301
  • [49] Computer-assisted delineation of hematoma from CT volume using autoencoder and Chan Vese model
    Manas Kumar Nag
    Saunak Chatterjee
    Anup Kumar Sadhu
    Jyotirmoy Chatterjee
    Nirmalya Ghosh
    International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 259 - 269
  • [50] Validation and estimation of spleen volume via computer-assisted segmentation on clinically acquired CT scans
    Yang, Yiyuan
    Tang, Yucheng
    Gao, Riqiang
    Bao, Shunxing
    Huo, Yuankai
    McKenna, Matthew T.
    Savona, Michael R.
    Abramson, Richard G.
    Landman, Bennett A.
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (01)