Effect of CT image compression on computer-assisted lung nodule volume measurement

被引:21
|
作者
Ko, LP [1 ]
Chang, J [1 ]
Bomsztyk, E [1 ]
Babb, JS [1 ]
Naidich, DP [1 ]
Rusinek, H [1 ]
机构
[1] NYU, Med Ctr, Dept Radiol, Thorac Imaging Sect, New York, NY 10016 USA
关键词
D O I
10.1148/radiol.2371041079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the effect of two-dimensional wavelet-based computed tomographic (CT) image compression according to the Joint Photographic Experts Group (JPEG) 2000 standard on computer-assisted assessment of nodule volume. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the research board at the authors' institution; patients' informed consent was not required. Fifty-one nodules in 23 patients (seven men, 16 women; mean age, 59 years; age range, 39-75 years) were selected on low-dose CT scans that were compressed to levels of 10:1, 20:1, 30:1, and 40:1 by using a two-dimensional JPEG 2000 wavelet-based image compression method. Nodules were classified according to size (<= 5 mm or > 5 mm in diameter), location (central, peripheral, or abutting pleura or fissures), and attenuation (solid, calcified, or subsolid). Regions of interest were placed on the original images and transposed onto compressed images. Nodule volumes on original (noncompressed) and compressed images were measured by using a computer-assisted method. A mixed-model analysis of variance was conducted for statistical evaluation. RESULTS: Nodule volumes averaged 388.1 mm(3) (range, 34-3474 mm(3)). There were three calcified, 33 solid noncalcified, and 15 subsolid nodules (13 with ground-glass attenuation). Average volume decreased with increasing compression level, to 383 mm(3) (10:1), 370 mm(3) (20:1), 360 mm(3) (30:1), and 354 mm(3) (40:1). No significant difference was identified between measurements obtained on original images and those compressed to a level of 10:1. Significant differences were noted, however, between original images and those compressed to a level of 20:1 or greater (P <.05). Compression level significantly interacted with nodule size, location, and attenuation (P <.001). The effect of compression was greater for nodules with ground-glass attenuation than for those with higher attenuation values. The difference in mean volumes between original images and those compressed to a level of 20:1 was 34.9 mm(3) for nodules with ground-glass attenuation, compared with 8.3 mm(3) for higher-attenuation nodules, a 4.2-fold difference. CONCLUSION: Nodule volumes measured on images compressed to a level of 20:1 differed significantly from those measured on noncompressed images, especially for nodules with ground-glass attenuation. This difference could affect the assessment of nodule change in size as measured with computer-assisted methods. (c) RSNA, 2005.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 50 条
  • [1] Computer-Assisted Image Processing System for Early Assessment of Lung Nodule Malignancy
    Shaffie, Ahmed
    Soliman, Ahmed
    Eledkawy, Amr
    van Berkel, Victor
    El-Baz, Ayman
    CANCERS, 2022, 14 (05)
  • [2] Computer-assisted lung nodule volumetry from multi-detector row CT: Influence of image reconstruction parameters
    Honda, Osamu
    Sumikawa, Hiromitsu
    Johkoh, Takeshi
    Tomiyama, Noriyuki
    Mihara, Naoki
    Inoue, Atsuo
    Tsubamoto, Mitsuko
    Natsag, Javzandulam
    Hamada, Seiki
    Nakamura, Hironobu
    EUROPEAN JOURNAL OF RADIOLOGY, 2007, 62 (01) : 106 - 113
  • [3] The effect of lung volume on nodule size on CT
    Petkovska, Iva
    Brown, Matthew S.
    Goldin, Jonathan G.
    Kim, Hyun J.
    McNitt-Gray, Michael F.
    Abtin, Fereidoun G.
    Ghurabi, Raffi J.
    Aberle, Denise R.
    ACADEMIC RADIOLOGY, 2007, 14 (04) : 476 - 485
  • [4] Partial volume effect on CT lung nodule volume measurement: Theoretical analysis and experimental evaluation
    Liang, Y
    Meyer, CA
    Krishinamurthi, G
    Winer-Muram, HT
    Jennings, SG
    RADIOLOGY, 2002, 225 : 570 - 570
  • [5] IMAGE MEASUREMENT TECHNIQUES UTILIZING A COMPUTER-ASSISTED COMPARATOR
    HELMERING, RJ
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1979, 45 (06): : 786 - 786
  • [6] Computer-assisted image processing for lung cancer localization
    Xie, SS
    Zheng, W
    Li, YS
    Lai, KZ
    Lin, QR
    LASERS IN MEDICINE AND DENTISTRY: DIAGNOSTICS AND TREATMENT, 1996, 2887 : 78 - 83
  • [7] New Method for Predicting CT Lung Nodule Volume Measurement Performance
    Avila, Ricardo S.
    Jirapatnakul, Artit
    Subramaniam, Raja
    Yankelevitz, David
    MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS, 2017, 10134
  • [8] Computer-assisted solid lung nodule 3D volumetry on CT: influence of scan mode and iterative reconstruction: a CT phantom study
    Coenen, Adriaan
    Honda, Osamu
    van der Jagt, Eric J.
    Tomiyama, Noriyuki
    JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (10) : 677 - 684
  • [9] Computer-assisted solid lung nodule 3D volumetry on CT: influence of scan mode and iterative reconstruction: a CT phantom study
    Adriaan Coenen
    Osamu Honda
    Eric J. van der Jagt
    Noriyuki Tomiyama
    Japanese Journal of Radiology, 2013, 31 : 677 - 684
  • [10] Computer Assisted Imaging for Nodule detection on a Multi-slice CT Image
    Singh, Manju
    Singh, H. R.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5, 2009, 25 : 301 - 304