Micro gamma camera optics with high sensitivity and resolution

被引:2
|
作者
MacDonald, CA [1 ]
Mail, N [1 ]
Gibson, WM [1 ]
Jorgensen, SM [1 ]
Ritman, EL [1 ]
机构
[1] SUNY Albany, Ctr Xray Opt, Albany, NY 12222 USA
关键词
nuclear medicine; gammacamera; radioscintigraphy; polycapillary x-ray optics;
D O I
10.1117/12.597193
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polycapillary x-ray optics are bundles of micron size hollow tubes, inside of which x rays are propagated by total reflection much like visible light in solid fiber optics. The small critical angle for total reflection from the glass walls of the tubes, 0.06 degrees at 27 keV, results in very high angular selectivity. The field of view of each capillary tube is limited by this angular acceptance to less than 50 microns at a source-to-optic distance of 2 cm. Each adjacent tube works in parallel so that a large area can be covered at this resolution with much higher count rate than for a single collimator. Measurements have been performed using I-125 brachytherapy seeds in Lucite phantoms using the optics and imaging detectors. Measured resolutions were detector-limited at better than 0.1 mm. Calculations for expected sensitivity and signal-to-background ratios were developed from geometrical models and show good agreement with measurements. Results indicate that the optics provide superior signal count rates to conventional collimators for geometries such as small animal imaging in which sub millimeter resolution with inch-wide or larger fields of view are desirable.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [21] High-resolution retinal imaging with micro adaptive optics system
    Niu, Saisai
    Shen, Jianxin
    Liang, Chun
    Zhang, Yunhai
    Li, Bangming
    APPLIED OPTICS, 2011, 50 (22) : 4365 - 4375
  • [22] The Image Processing for Improvement of Angular Resolution and Sensitivity of the Portable Gamma Camera with Medipix Detector
    Ivanov, Oleg P.
    Potapov, Victor N.
    Stepanov, Vyacheslav E.
    Martinyuk, Yury N.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [23] Characterisation of a high resolution small field of view portable gamma camera
    Bugby, S. L.
    Lees, J. E.
    Bhatia, B. S.
    Perkins, A. C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03): : 331 - 339
  • [24] INTRINSIC RESOLUTION OF A GAMMA CAMERA SYSTEM
    SVEDBERG, JB
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (04): : 514 - &
  • [25] PINHOLE COLLIMATOR INSERT FOR HIGH SPATIAL RESOLUTION AND DETECTION SENSITIVITY ANGER CAMERA IMAGING OF 511-KEV GAMMA RAYS
    KHENTIGAN, A
    DOSREMED.LV
    WINCHELL, HS
    JOURNAL OF NUCLEAR MEDICINE, 1971, 12 (06) : 442 - +
  • [27] High resolution and sensitivity gamma camera with active septa. A first Monte Carlo study (vol 9, 18431, 2019)
    Ilisie, Victor
    Moliner, Laura
    Oliver, Sandra
    Sanchez, Filomeno
    Gonzalez, Antonio J.
    Seimetz, Michael
    Rodriguez-Alvarez, Maria J.
    Benlloch, Jose Maria
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [28] Rapid photo-lithographic technique for high resolution micro-optics
    Dumbravescu, N
    ADVANCED TOPICS IN OPTOELECTRONICS, MICROELECTRONICS, AND NANOTECHNOLOGIES, 2002, 5227 : 349 - 354
  • [29] An improved method for measurement of gamma camera sensitivity for high energy photons.
    Wagenaar, DJ
    Zimmerman, RF
    Hill, TC
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 876 - 876
  • [30] Performance of a high-resolution hybrid gamma/optical camera for intraoperative imaging
    Bugby, Sarah
    Lees, John
    Perkins, Alan
    Bassford, Dave
    Blake, Oliver
    Blackshaw, Patricia
    Bhatia, Bahadar
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55