Micro gamma camera optics with high sensitivity and resolution

被引:2
|
作者
MacDonald, CA [1 ]
Mail, N [1 ]
Gibson, WM [1 ]
Jorgensen, SM [1 ]
Ritman, EL [1 ]
机构
[1] SUNY Albany, Ctr Xray Opt, Albany, NY 12222 USA
关键词
nuclear medicine; gammacamera; radioscintigraphy; polycapillary x-ray optics;
D O I
10.1117/12.597193
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polycapillary x-ray optics are bundles of micron size hollow tubes, inside of which x rays are propagated by total reflection much like visible light in solid fiber optics. The small critical angle for total reflection from the glass walls of the tubes, 0.06 degrees at 27 keV, results in very high angular selectivity. The field of view of each capillary tube is limited by this angular acceptance to less than 50 microns at a source-to-optic distance of 2 cm. Each adjacent tube works in parallel so that a large area can be covered at this resolution with much higher count rate than for a single collimator. Measurements have been performed using I-125 brachytherapy seeds in Lucite phantoms using the optics and imaging detectors. Measured resolutions were detector-limited at better than 0.1 mm. Calculations for expected sensitivity and signal-to-background ratios were developed from geometrical models and show good agreement with measurements. Results indicate that the optics provide superior signal count rates to conventional collimators for geometries such as small animal imaging in which sub millimeter resolution with inch-wide or larger fields of view are desirable.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] A high sensitivity, electronically collimated gamma camera
    Tumer, TO
    Yin, S
    Kravis, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 899 - 904
  • [2] CHARACTERISTICS OF A HIGH SENSITIVITY COLLIMATOR FOR GAMMA CAMERA
    BAUER, TJ
    BROOKEMAN, VA
    DELAND, FH
    JOURNAL OF NUCLEAR MEDICINE, 1971, 12 (06) : 414 - +
  • [3] A high sensitivity, electronically collimated gamma camera
    Tumer, TO
    Yin, S
    Kravis, S
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 297 - 301
  • [4] High resolution and sensitivity gamma camera with active septa. A first Monte Carlo study
    Ilisie, Victor
    Moliner, Laura
    Oliver, Sandra
    Sanchez, Filomeno
    Gonzalez, Antonio J.
    Seimetz, Michael
    Rodriguez-Alvarez, Maria J.
    Maria Benlloch, Jose
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [5] High resolution and sensitivity gamma camera with active septa. A first Monte Carlo study
    Victor Ilisie
    Laura Moliner
    Sandra Oliver
    Filomeno Sánchez
    Antonio J. González
    Michael Seimetz
    Maria J. Rodríguez-Álvarez
    Jose Maria Benlloch
    Scientific Reports, 9
  • [6] LumaGEM: High-resolution dedicated gamma camera
    MacDonald, LR
    Patt, BE
    Iwanczyk, JS
    McElroy, D
    Hoffman, EJ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 56P - 56P
  • [7] Readout electronics of a high-resolution gamma camera
    Zhang, Mengjiao
    Qi, Yujin
    He Jishu/Nuclear Techniques, 2007, 30 (07): : 629 - 632
  • [8] CONSEQUENCES OF CRYSTAL THICKNESS REDUCTION ON GAMMA-CAMERA RESOLUTION AND SENSITIVITY
    SANO, RM
    TINKEL, JB
    LAVALLEE, CA
    FREEDMAN, GS
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (06) : 712 - 713
  • [9] A high resolution, high sensitivity PET camera dedicated to breast imaging
    Vandenbroucke, A.
    Lau, F.
    Reynolds, P. D.
    Innes, D.
    Zhai, J.
    Levin, C. S.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (04) : 674 - 674
  • [10] Performance characterization of a miniature, high sensitivity gamma ray camera
    Olcott, Peter D.
    Habte, Frezghie
    Foudray, Angela M.
    Levin, Craig S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1492 - 1497