High-resolution micro-CT evaluation of mid- to long-term effects of estrogen deficiency on rat trabecular bone

被引:29
|
作者
Yang, J
Pham, SM
Crabbe, DL
机构
[1] Temple Univ, Sch Dent, Div Oral & Maxillofacial Radiol, Dept Oral & Maxillofacial Pathol Med & Surg, Philadelphia, PA 19140 USA
[2] Temple Univ, Sch Med, Dept Med, Philadelphia, PA 19122 USA
关键词
micro-CT; trabecular bone; osteoporosis; ovariectomy; estrogen deficiency;
D O I
10.1016/S1076-6332(03)00109-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Previous studies have shown dramatic short-term bone loss following ovariectomy. The purpose of this study was to evaluate mid- to long-term effects of estrogen deficiency on microarchitecture of tibial trabecular bone using a high-resolution microcomputed tomography (Micro-CT). Materials and Methods. Twenty-eight female rats were divided into two equal groups: ovariectomized (OVX, n = 14) and sham-operated (SOVX, n = 14), which in turn were divided into two equal subgroups (euthanized either 6 or 16 weeks after surgery). The left tibia of each animal was scanned with a high-resolution micro-CT (Skyscan 1072 micro-CT system; SkyScan, Aartselaar, Belgium). The Micro-CT system used an X-ray CCD-camera with a cooled 1024 x 1024-pixel 12-bit sensor. Results. Ovariectomy significantly decreased the ratio of bone volume:tissue volume (-42% at 6 weeks and -69% at 16 Weeks) and trabecular thickness (-13% at 6 weeks and -30% at 16 weeks), while significantly increasing trabecular separation (+73% at 6 weeks and +100% at 16 weeks) and structure model index (+15% at 6 weeks and +48% at 16 weeks), when compared with SOVX, from 6 to 16 weeks. Conclusion. Based on the experimental results, there are alterations of trabecular microarcihtecture in the tibia following mid- and long-term estrogen deficiency. More rod-shaped trabeculae are formed with increasing duration of estrogen deficiency. The high-resolution micro-CT imaging system is useful to evaluate the mid- to long-term trabecular changes seen with estrogen deficiency or osteoporosis.
引用
收藏
页码:1153 / 1158
页数:6
相关论文
共 50 条
  • [21] Comparison of high-resolution X-ray and micro-CT for experimental evaluation of intracranial stent prototypes: quality evaluation beyond CE mark
    Keuler, Andreas
    Taschner, Christian
    Brockmann, Marc Alexander
    Boll, Hanne
    Foerster, Katharina
    Lutz, Lisa
    Herrmann-Frank, Annegret
    Lelgemann, Monika
    Schumacher, Martin
    NEURORADIOLOGY, 2014, 56 (04) : 315 - 323
  • [22] Comparison of high-resolution X-ray and micro-CT for experimental evaluation of intracranial stent prototypes: quality evaluation beyond CE mark
    Andreas Keuler
    Christian Taschner
    Marc Alexander Brockmann
    Hanne Boll
    Katharina Förster
    Lisa Lutz
    Annegret Herrmann-Frank
    Monika Lelgemann
    Martin Schumacher
    Neuroradiology, 2014, 56 : 315 - 323
  • [23] Effects of Long-Term Sclerostin Deficiency on Trabecular Bone Mass and Adaption to Limb Loading Differ in Male and Female Mice
    Albiol, Laia
    Buettner, Alexander
    Pflanz, David
    Mikolajewicz, Nicholas
    Birkhold, Annette I.
    Kramer, Ina
    Kneissel, Michaela
    Duda, Georg N.
    Checa, Sara
    Willie, Bettina M.
    CALCIFIED TISSUE INTERNATIONAL, 2020, 106 (04) : 415 - 430
  • [24] Effects of Long-Term Sclerostin Deficiency on Trabecular Bone Mass and Adaption to Limb Loading Differ in Male and Female Mice
    Laia Albiol
    Alexander Büttner
    David Pflanz
    Nicholas Mikolajewicz
    Annette I. Birkhold
    Ina Kramer
    Michaela Kneissel
    Georg N. Duda
    Sara Checa
    Bettina M. Willie
    Calcified Tissue International, 2020, 106 : 415 - 430
  • [25] Evaluation of the mid- and long-term effects of a private car driving–restriction policy under the carbon emission peak target
    Zhen Chen
    Xiangyang Ye
    Bing Li
    Shuwei Jia
    Environmental Science and Pollution Research, 2023, 30 : 44706 - 44723
  • [26] Evaluation of the mid- and long-term effects of a private car driving-restriction policy under the carbon emission peak target
    Chen, Zhen
    Ye, Xiangyang
    Li, Bing
    Jia, Shuwei
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (15) : 44706 - 44723
  • [27] A high-resolution, long-term wave resource assessment of Japan with wave-current effects
    Webb, A.
    Waseda, T.
    Kiyomatsu, K.
    RENEWABLE ENERGY, 2020, 161 : 1341 - 1358
  • [28] Long-Term Experimental Evaluation of a High-Resolution Atmospheric General Circulation Model From a Hydrological Perspective
    Miura, Yosuke
    Nakaegawa, Toshiyuki
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2024, 129 (03)
  • [29] Long-term evaluation of the remineralization of interproximal caries-like lesions adjacent to glass-ionomer restorations:: A micro-CT study
    Lee, Hyeok-Sang
    Berg, Joel H.
    Garcia-Godoy, Franklin
    Jang, Ki-Taeg
    AMERICAN JOURNAL OF DENTISTRY, 2008, 21 (02): : 129 - 132
  • [30] Long-term follow-up high-resolution CT findings in non-specific interstitial pneumonia
    Akira, Masanori
    Inoue, Yoshikazu
    Arai, Toru
    Okuma, Tomohisa
    Kawata, Yutaka
    THORAX, 2011, 66 (01) : 61 - 65