Real-time ultrasound elastography evaluation of achilles tendon properties in patients with mild hemiplegic stroke after rehabilitation training

被引:5
|
作者
Shao, Yu-Hong [1 ]
Peng, Ze [1 ]
Kong, Xun [1 ]
Wang, Bin [1 ]
Zhang, Hui [1 ]
机构
[1] Peking Univ, Hosp 1, Dept Ultrasound, 8 Xishiku St, Beijing 100034, Peoples R China
关键词
Achilles tendon; elastography; stroke; ultrasound; SONOELASTOGRAPHY FINDINGS; VISCOELASTIC PROPERTIES; MECHANICAL-PROPERTIES; IN-VIVO; ADAPTATION; IDENTIFICATION; RELIABILITY; STIFFNESS; CHILDREN; EXERCISE;
D O I
10.1002/jum.14755
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective This study aims to evaluate the Achilles tendon's properties after rehabilitation training in patients with stroke using real-time ultrasound elastography. Methods A total of 24 patients with mild hemiplegic stroke in the past 6 to 12 months and unilateral lower limb movement disorder were prospectively enrolled. All patients accepted 9-week rehabilitation training with the same schema. The 2-dimensional elastography and real-time elastography findings in the impaired and contralateral normal Achilles tendon were measured at pretraining and at 3, 6, and 9 weeks after training, which included tendon length, thickness, elasticity score (grade 1-3), and strain ratio of fat to tendon. The functional properties, which include the 10-meter walk test and timed up-and-go scores, were evaluated before and after the 9-week training. Results The impaired Achilles tendon had a longer length (P = .002), lower frequency of grade 1 (P = .012), and lower strain ratio (P = .009) than the contralateral tendon before training. The impaired tendons at the third, sixth, and ninth weeks after training were compared to ones before training, respectively, which revealed shorter length, increased frequency of grade 1, and increased strain ratio. The first statistically significant changes in the length were observed at the sixth week, while such changes in elasticity score and strain ratio were observed at the ninth week. Conclusions Two-dimensional elastography and real-time elastography can provide valuable imaging markers for quantitatively evaluating the Achilles tendon's properties after rehabilitation training in patients with stroke.
引用
收藏
页码:713 / 723
页数:11
相关论文
共 50 条
  • [11] Evaluation of Parotid Glands With Real-time Ultrasound Elastography in Children
    Gungor, Gulay
    Yurttan, Nursel
    Bilal, Nagihan
    Menzicioglu, Mehmet Sait
    Duymus, Mahmut
    Avcu, Serhat
    Citil, Serdal
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (03) : 611 - 615
  • [12] Real-time ultrasound elastography evaluation of the thyroid gland in adolescent patients with hashimoto thyroiditis
    Cekic, Bulent
    Parlak, Ayse Eda
    Koksel, Yasemin
    Toslak, Iclal Erdem
    Parlak, Mesut
    [J]. BIOMEDICAL RESEARCH-INDIA, 2017, 28 (17): : 7534 - 7539
  • [13] Evaluation of varicocele patients using the testicular real-time elastography
    Blgozah, S.
    Shaaban, M.
    Sakr, M. A.
    Salama, N.
    [J]. HUMAN REPRODUCTION, 2015, 30 : 139 - 139
  • [14] Evaluation of Elastic Stiffness in Healing Achilles Tendon After Surgical Repair of a Tendon Rupture Using In Vivo Ultrasound Shear Wave Elastography
    Zhang, Li-ning
    Wan, Wen-bo
    Wang, Yue-xiang
    Jiao, Zi-yu
    Zhang, Li-hai
    Luo, Yu-kun
    Tang, Pei-fu
    [J]. MEDICAL SCIENCE MONITOR, 2016, 22 : 1186 - 1191
  • [15] Evaluation of human muscle hardness after dynamic exercise with ultrasound real-time tissue elastography: A feasibility study
    Yanagisawa, O.
    Niitsu, M.
    Kurihara, T.
    Fukubayashi, T.
    [J]. CLINICAL RADIOLOGY, 2011, 66 (09) : 815 - 819
  • [16] Hepatic Elasticity in Patients With Ascites: Evaluation With Real-Time Tissue Elastography
    Hirooka, Masashi
    Koizumi, Yohei
    Hiasa, Yoichi
    Abe, Masanori
    Ikeda, Yoshio
    Matsuura, Bunzo
    Onji, Morikazu
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : W766 - W771
  • [17] Improving B mode ultrasound evaluation of breast lesions with real-time ultrasound elastography - A clinical approach
    Tan, S. M.
    Teh, H. S.
    Mancer, J. F. Kent
    Poh, W. T.
    [J]. BREAST, 2008, 17 (03): : 252 - 257
  • [18] Real-time sonoelastography evaluation of the Achilles tendon following ultrasound-guided platelet-rich plasma injection and eccentric exercise for the treatment of refractory Achilles tendinopathy
    Ooi, Chin Chin
    Schneider, Michal
    Malliaras, Peter
    Png, Meng Ai
    Chadwick, Martine
    Jones, Donna
    Venkatanarasimha, Nanda
    Connell, David
    [J]. ULTRASOUND, 2019, 27 (03) : 138 - 147
  • [19] Evaluation of Hand Tendon Elastic Properties During Rehabilitation Through High-Frequency Ultrasound Shear Elastography
    Chen, Pei-Yu
    Yang, Tai-Hua
    Kuo, Li-Chieh
    Hsu, Hsiu-Yun
    Su, Fong-Chin
    Huang, Chih-Chung
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (08) : 2716 - 2726
  • [20] TRAINING BASED ON REAL-TIME MOTION EVALUATION FOR FUNCTIONAL REHABILITATION IN VIRTUAL ENVIRONMENT
    Van-Hanh Nguyen
    Merienne, Frederic
    Martinez, Jean-Luc
    [J]. INTERNATIONAL JOURNAL OF IMAGE AND GRAPHICS, 2010, 10 (02) : 235 - 250