Mathematical Modeling of a Bioluminescent E. Coli Based Biosensor

被引:5
|
作者
Rabner, A. [1 ]
Martinez, E. [2 ]
Pedhazur, R. [3 ]
Elad, T. [3 ]
Belkin, S. [3 ]
Shacham, Y. [1 ]
机构
[1] Tel Aviv Univ, Dept Phys Elect, IL-69978 Tel Aviv, Israel
[2] Tel Aviv Univ, Dept Biomed Engn, IL-69978 Tel Aviv, Israel
[3] Hebrew Univ Jerusalem, Dept Plant & Environm Sci, IL-91904 Jerusalem, Israel
来源
NONLINEAR ANALYSIS-MODELLING AND CONTROL | 2009年 / 14卷 / 04期
关键词
bioluminescence; enzymes; biosensor; promoting; reporting; photons; luciferase; aldehyde; fatty acid; ESCHERICHIA-COLI; SOS RESPONSE; OXYGEN-CONSUMPTION; DYNAMICS; KINETICS; SYSTEM; MUTANT; DEFICIENT; INDUCTION; LEXA;
D O I
10.15388/NA.2009.14.4.14471
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
In this work we present a mathematical model for the bioreporter activity of an E. coli based bioluminescent bioreporter. This bioreporter is based on a genetically modified E. coli which harbors the recA promoter, a member of the bacterial SOS response, fused to the bacterial luminescence (lux) genes. This bioreporter responds to the presence of DNA damaging agents such as heavy metals, H2O2 and Nalidixic Acid (NA) that activate the SOS response. In our mathematical model we implemented basic physiological mechanisms such as: the penetration of the NA into the biosensor; gyrase enzyme inhibition by the NA; gyrase level regulation; creation of chromosomal DNA damage; DNA repair and release of ssDNA into the cytoplasm; SOS induction and chromosomal DNA repair; activation of lux genes by the fused recA promoter carried on a plasmidal DNA; transcription and translation of the luminescence responsible enzymes; luminescence cycle; energy molecules level regulation and the regulation of the O-2 consumption. The mathematical model was defined using a set of ordinary differential equations (ODE) and solved numerically. We simulated the system for different concentrations of NA in water for specific biosensors concentration, and under limited O-2 conditions. The simulated results were compared to experimental data and satisfactory matching was obtained. This manuscript presents a proof of concept showing that real biosensors can be modeled and simulated. This sets the ground to the next stage of implementing a comprehensive physiological model using experimentally extracted parameters. Following the completion of the next stage, it will be possible to construct a "Computer Aided Design" tool for the simulation of the genetically engineered biosensors. We define a term "bioCAD" for a Biological System Computer Aided Design. The specific bioCAD that is described here is aimed towards whole cell biosensors which are under investigation today for functional sensing. Usage of the bioCAD will improve the biosensors design process and boost their performance. It will also reduce Non Recurring Engineering (NRE) cost and time. Finally, using a parameterized solution will allow fair and quick evaluation of whole cell biosensors for various applications.
引用
收藏
页码:505 / 529
页数:25
相关论文
共 50 条
  • [31] Modeling the colloidal physics of translation elongation in E. coli
    Maheshwari, Akshay
    Gonzalez-Gonzalez, Emma
    Sunol, Alp M.
    Endy, Drew
    Zia, Roseanna N.
    BIOPHYSICAL JOURNAL, 2022, 121 (03) : 122 - 122
  • [32] Monitoring of nutrient limitation in growing E-coli: a mathematical model of a ppGpp-based biosensor
    Pokhilko, Alexandra
    BMC SYSTEMS BIOLOGY, 2017, 11
  • [33] Ascending Vaginal Bacterial Infection with Bioluminescent E. coli Induces Perinatal Neuroinflammation in Mice.
    Boyle, Ashley K.
    Suff, Natalie
    Waddington, Simon N.
    Peebles, Donald
    REPRODUCTIVE SCIENCES, 2020, 27 (SUPPL 1) : 207A - 207A
  • [34] Monitoring of bactericidal action of laser by in vivo imaging of bioluminescent E. coli in a cutaneous wound infection
    Samir Jawhara
    Serge Mordon
    Lasers in Medical Science, 2006, 21 : 153 - 159
  • [35] A novel spr biosensor for rapid label-free detection of E. Coli
    Shin, H.
    Lim, W. K.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 124 : 6 - 6
  • [36] Design of ultra-high sensitive biosensor to detect E. Coli in water
    Roy S.K.
    Sharan P.
    International Journal of Information Technology, 2020, 12 (3) : 775 - 780
  • [37] Numerical modeling of the dynamic response of a bioluminescent bacterial biosensor
    Mahmoud Affi
    Camille Solliec
    Patrick Legentilhomme
    Jacques Comiti
    Jack Legrand
    Sulivan Jouanneau
    Gérald Thouand
    Analytical and Bioanalytical Chemistry, 2016, 408 : 8761 - 8770
  • [38] Magnetic Particle Enhanced Microcantilever Biosensor for Rapid and Sensitive E. Coli Detection
    Polyzoev, Vasco
    Enikov, Eniko
    Heinze, Brian
    Yoon, Jeong-Yeol
    ISOT: 2009 INTERNATIONAL SYMPOSIUM ON OPTOMECHATRONIC TECHNOLOGIES, 2009, : 377 - +
  • [39] Estimation of Hg(II) in Soil Samples by Bioluminescent Bacterial Bioreporter E. coli ARL1, and the Effect of Humic Acids and Metal Ions on the Biosensor Performance
    Branyikova, Irena
    Lucakova, Simona
    Kuncova, Gabriela
    Trogl, Josef
    Synek, Vaclav
    Rohovec, Jan
    Navratil, Tomas
    SENSORS, 2020, 20 (11)
  • [40] Numerical modeling of the dynamic response of a bioluminescent bacterial biosensor
    Affi, Mahmoud
    Solliec, Camille
    Legentilhomme, Patrick
    Comiti, Jacques
    Legrand, Jack
    Jouanneau, Sulivan
    Thouand, Gerald
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (30) : 8761 - 8770