Static secondary ion mass spectrometry (S-SIMS) is one of the potentially most powerful and versatile tools for the analysis of surface components at the monolayer level. Current improvements in detection limit (LOD) and molecular specificity rely on the optimisation of the desorption-ionisation (DI) process. As an alternative to monoatomic projectiles, polyatomic primary ion (P.I.) bombardment increases ion yields non-linearly. Common P.I. sources are Ga+ (liquid metal ion gun (LMIG)), SF5+ (electron ionisation) and the newer Au-n(+), Bi-n(q+) (both LMIG) and C-60(+) (electron ionisation) sources. In this study the ion yield improvement obtained by using the newly developed ion sources is assessed. Two dyes (zwitterionic and/or thermolabile polar functionalities on a largely conjugated backbone) were analysed as a thin layer using Ga+, SF5+, C-60(+), Bi+, Bi-3(2+) and Bi-5(2+) projectiles under static conditions. The study aims at evaluating the improvement in LOD, useful and characteristic yield and molecular specificity. The corrected total ion count values for the different P.I. sources are compared for different instruments to obtain a rough estimate of the improvements. Furthermore, tentative ionisation and fragmentation schemes are provided to describe the generation of radical and adduct ions. Characteristic ion yields are discussed for the different P.I. sources. An overview of the general appearances of the mass spectra obtained with the different P.I. sources is given to stress the major improvement provided by polyatomic P.I.s in yielding information at higher m/z values. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:1481 / 1496
页数:16
相关论文
共 50 条
  • [41] Ion beam generation from an electrolyte solution containing polyatomic cations and anions for secondary ion mass spectrometry
    National Institute of Advanced Industrial Science and Technology , Tsukuba Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan
    不详
    Jpn. J. Appl. Phys., 12
  • [42] Ion Beam Generation from an Electrolyte Solution Containing Polyatomic Cations and Anions for Secondary Ion Mass Spectrometry
    Fujiwara, Yukio
    Watanabe, Kouji
    Saito, Naoaki
    Nonaka, Hidehiko
    Suzuki, Atsushi
    Nakanaga, Taisuke
    Fujimoto, Toshiyuki
    Kurokawa, Akira
    Ichimura, Shingo
    Tomita, Mitsuhiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2009, 48 (12)
  • [43] STATIC SECONDARY-ION MASS-SPECTROMETRY OF ADSORBED PROTEINS
    MANTUS, DS
    RATNER, BD
    CARLSON, BA
    MOULDER, JF
    ANALYTICAL CHEMISTRY, 1993, 65 (10) : 1431 - 1438
  • [44] CHARACTERIZATION OF RUBBER SURFACES BY STATIC SECONDARY ION MASS-SPECTROMETRY
    VANOOIJ, WJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 52 - MACRO
  • [45] Suppression and enhancement of secondary ion formation due to the chemical environment in static-secondary ion mass spectrometry
    Jones, Emrys A.
    Lockyer, Nicholas P.
    Kordys, Jeanette
    Vickerman, John C.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (08) : 1559 - 1567
  • [46] ORGANIC ION IMAGING BEYOND THE LIMIT OF STATIC SECONDARY-ION MASS-SPECTROMETRY
    MCMAHON, JM
    DOOKERAN, NN
    TODD, PJ
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (11) : 1047 - 1058
  • [47] Suppression and Enhancement of Secondary Ion Formation Due to the Chemical Environment in Static-Secondary Ion Mass Spectrometry
    Jones, Emrys A.
    Lockyer, Nicholas P.
    Kordys, Jeanette
    Vickerman, John C.
    Journal of the American Society for Mass Spectrometry, 2007, 18 (08): : 1559 - 1567
  • [48] LIQUID SECONDARY ION MASS-SPECTROMETRY WITH A FOCUSED PRIMARY ION-SOURCE
    STOLL, RG
    HARVAN, DJ
    HASS, JR
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1984, 61 (01): : 71 - 79
  • [49] O-3(+) cluster primary ion bombardment for secondary ion mass spectrometry
    Yamazaki, H
    Mitani, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 124 (01): : 91 - 94
  • [50] Dependence of Megaelectron Volt Time-of-Flight Secondary Ion Mass Spectrometry Secondary Molecular Ion Yield from Phthalocyanine Blue on Primary Ion Stopping Power
    Brajkovic, Marko
    Barac, Marko
    Radovic, Iva Bogdanovic
    Siketic, Zdravko
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (07) : 1518 - 1524