On selection of supplementary input signals for STATCOM to damp inter-area oscillations in power systems

被引:0
|
作者
Farsangi, MM [1 ]
Song, YH [1 ]
Lee, KY [1 ]
机构
[1] Kerman Univ, Kerman, Iran
关键词
STATCOM; inter-area oscillation; stabilizing signal; input-output controllability analysis; minimum singular value; right half plane zeros; relative gain array;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a method to select the supplementary input signal for systems equipped with STATic synchronous COMpensators (STATCOM) to damp inter-area mode(s). Input-output observabiliy-controllability analysis, minimum singular value, right half plane zeros and relative gain array are used to assess the most appropriate supplementary input signal. The open-loop frequency of the system is shown to examine the sensitivity of the selected supplementary input signal to inter-area mode. The method is applied to select the input signal for a small power system equipped with a single STATCOM and for a large power system equipped with two STATCOMs.
引用
下载
收藏
页码:3068 / 3073
页数:6
相关论文
共 50 条
  • [1] Selection of Global Input Signals for Wide-area PSS to Damp Inter-area Oscillations in Multi-machine Power Systems
    Li Chunyan
    Sun Yuanzhang
    Chen Xiangyi
    Ma Zhanjun
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [2] Selection of an Optimal Control Channel for STATCOM-Based Stabilizers to Damp Inter-Area Oscillations
    Shakarami, M. R.
    Khoy, M. Khoram
    2014 22nd Iranian Conference on Electrical Engineering (ICEE), 2014, : 580 - 584
  • [3] Robust design of a TCSC supplementary controller to damp inter-area oscillations
    Kuiava, Roman
    Ramos, Rodrigo A.
    Bretas, Newton G.
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 1462 - 1469
  • [4] Control loops selection to damp inter-area oscillations of electrical networks
    Heniche, A
    Kamwa, I
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2002, 17 (02) : 378 - 384
  • [5] Control loops selection to damp inter-area oscillations of electrical networks
    Heniche, A
    Kamwa, I
    2002 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2002, : 240 - 240
  • [6] A Measurement-based Control Input-output Signal Selection Approach to Damp Inter-area Oscillations
    Bai, Feifei
    Liu, Hesen
    Zhu, Lin
    Liu, Yilu
    Sun, Kai
    Wang, Xiaoru
    Patel, Mahendra
    Farantatos, Evangelos
    2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2015,
  • [7] Identification and Monitoring Inter-area Oscillations in Power Systems
    Calderon-Guizar, Jorge G.
    Ramirez-Gonzalez, M.
    Castellanos-Bustamante, R.
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [8] A latencies tolerant model predictive control approach to damp Inter-area oscillations in delayed power systems
    Molina-Cabrera, Alexander
    Rios, Mario A.
    Besanger, Yvon
    HadjSaid, Nouredine
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 98 : 199 - 208
  • [9] Damping Inter-Area Oscillations in Power Systems by STATCOMs
    Zarghami, Mahyar
    Crow, Mariesa. L.
    2008 40TH NORTH AMERICAN POWER SYMPOSIUM (NAPS 2008), 2008, : 255 - 260
  • [10] Intelligent control of inter-area oscillations in power systems
    Pugliese, P
    Sbrizzai, R
    Trovato, M
    LaScala, M
    MELECON '96 - 8TH MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, PROCEEDINGS, VOLS I-III: INDUSTRIAL APPLICATIONS IN POWER SYSTEMS, COMPUTER SCIENCE AND TELECOMMUNICATIONS, 1996, : 737 - 741