Development of a point-of-care test for the detection of MDMA in latent fingerprints using surface plasmon resonance and lateral flow technology

被引:6
|
作者
Pollard, Caroline [1 ]
Hudson, Mark [2 ]
McDonnell, James M. [3 ]
Royall, Paul G. [4 ]
Wolff, Kim [1 ]
机构
[1] Kings Coll London, Kings Forens, Dept Analyt Environm & Forens Sci, Franklin Wilkins Bldg,150 Stamford St, London SE1 9NH, England
[2] Intelligent Fingerprinting, Cambridge, England
[3] Kings Coll London, Randall Ctr Cell & Mol Biophys, London, England
[4] Kings Coll London, Inst Pharmaceut Sci, Franklin Wilkins Bldg, London, England
基金
英国生物技术与生命科学研究理事会;
关键词
amphetamines; Biacore; ecstasy; fingermark; sweat; ORAL FLUID; METABOLITES; DRUGS; DISPOSITION; ECSTASY; SALIVA; URINE;
D O I
10.1002/dta.3196
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To date, a specific point-of-care test (POCT) for 3,4-methylenedioxymethamphetamine (MDMA, ecstasy, 'E') in latent fingerprints (LFPs) has not been explored. Other POCTs identify MDMA in sweat by detecting the drug as a cross-reactant rather than target analyte, thus decreasing the test's sensitivity. The study's aim was to design a sensitive POCT for the detection of MDMA in LFPs using surface plasmon resonance (SPR) and lateral flow immunoassay (LFA) technology. A high-affinity antibody binding pair was identified using the former technique, deeming the pair suitable for a LFA. Titrations of fluorescently labelled antibody and antigen concentrations were tested to identify a sharp drop-in signal upon the addition of MDMA to allow a clear distinction between negative and positive outcomes. We trialled the LFA by producing dose response curves with MDMA and a group of drugs that share a similar chemical structure to MDMA. These were generated through spiking the LFA with increasing levels of drug (0-400 pg/10 mu l of MDMA; 0-10,000 pg/10 mu l of cross-reactant). Fluorescent test signals were measured using a cartridge reader. The cut-off (threshold) 60 pg/10 mu l calculated better cartridge performance (1.00 sensitivity, 0.95 specificity and 0.98 accuracy), when compared with 40 pg/10 mu l. The biggest cross-reactant was PMMA (250%), followed by MDEA (183%), MBDB (167%), MDA (16%) and methamphetamine (16%). A sensitive LFP screening tool requiring no sample preparation was successfully designed.
引用
收藏
页码:613 / 621
页数:9
相关论文
共 50 条
  • [21] Point-of-care multiplexed surface plasmon resonance system for rapid biomarker detection supporting rapid diagnostics and treatment monitoring
    Polonschii, Cristina
    Ursu, Dan
    Rosu-Hamzescu, Mihnea
    David, Sorin
    Gheorghiu, Eugen
    OPTICAL DIAGNOSTICS AND SENSING XXIV:TOWARD POINT-OF-CARE DIAGNOSTICS, 2024, 12850
  • [22] Development of Automated Detection and Wireless Reporting for a Handheld Point-of-Care Test
    Pardy, Tamas
    Filograno, Massimo Leonardo
    Baumann, Cindy
    Rang, Toomas
    2020 17TH BIENNIAL BALTIC ELECTRONICS CONFERENCE (BEC), 2020,
  • [23] Detection of biological analytes using Surface Plasmon Resonance as a biosensing technique for possible development of a point of care diagnostic tool.
    Malabi, Rudzani
    Manoto, Sello
    Ombinda-Lemboumba, Saturnin
    Maaza, Malik
    Mthunzi-Kufa, Patience
    PLASMONICS IN BIOLOGY AND MEDICINE XVI, 2019, 10894
  • [24] Improved point-of-care detection of P. gingivalis using optimized surface-enhanced Raman scattering in lateral flow assays
    Kissell, Lyndsay N.
    Han, Daewoo
    Vang, Der
    Cikanek, Alexander W. R.
    Steckl, Andrew J.
    Strobbia, Pietro
    SENSORS & DIAGNOSTICS, 2024, 3 (05): : 839 - 849
  • [25] Evaluation of a lateral flow assay-based IFN-γ release assay as a point-of-care test for the diagnosis of latent tuberculosis infection
    Lee, Hoon Hee
    Choi, Dong Hwan
    Kim, Jeong-Ran
    Kim, Young Gyun
    Jo, Kyung-Wook
    Shim, Tae Sun
    CLINICAL RHEUMATOLOGY, 2021, 40 (09) : 3773 - 3781
  • [26] Non-Invasive Point-of-Care Detection of Methamphetamine and Cocaine via Aptamer-Based Lateral Flow Test
    Erkocyigit, Bilge
    Man, Ezgi
    Efecan, Ece
    Ozufuklar, Ozge
    Devecioglu, Deniz
    Bagci, Basak
    Aldemir, Ebru
    Coskunol, Hakan
    Evran, Serap
    Celik, Emine Guler
    BIOSENSORS-BASEL, 2025, 15 (01):
  • [27] Detection of Ralstonia solanacearum using portable surface plasmon resonance technology
    Zhao, L.
    Levy, L.
    Di, R.
    PHYTOPATHOLOGY, 2013, 103 (06) : 167 - 168
  • [28] An account of the current status of point-of-care lateral flow tests for kidney biomarker detection
    Sahare, Tileshwar
    Sahoo, Badri Narayana
    Jaiswal, Surbhi
    Rana, Simran
    Joshi, Abhijeet
    ANALYST, 2024, 149 (19) : 4811 - 4829
  • [29] Smartphone-read phage lateral flow assay for point-of-care detection of infection
    Chabi, Maede
    Vu, Binh
    Brosamer, Kristen
    Smith, Maxwell
    Chavan, Dimple
    Conrad, Jacinta C. C.
    Willson, Richard C. C.
    Kourentzi, Katerina
    ANALYST, 2023, 148 (04) : 839 - 848
  • [30] A Sandwich-type Lateral Flow Strip Using a Split, Single Aptamer for Point-of-Care Detection of Cocaine
    Le Jing
    Chong-Yu Xie
    Qian-Qian Li
    Hui-Fang Yao
    Mei-Qing Yang
    Hui Li
    Fan Xia
    Shao-Guang Li
    Journal of Analysis and Testing, 2022, 6 : 120 - 128