MR imaging of brain: Comparison between SS-FSE and fast spin-echo T2-weighted pulse sequences

被引:0
|
作者
Seo, JJ [1 ]
Kang, HK [1 ]
Jeong, GW [1 ]
Jeong, YY [1 ]
Kim, JK [1 ]
Park, JG [1 ]
Chung, TW [1 ]
Kim, YH [1 ]
机构
[1] Chonnam Univ, Sch Med, Dept Diagnost Radiol, Kwangju 501190, South Korea
来源
关键词
brain lesions; MR; technique;
D O I
10.1177/19714009980110S237
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We compared quantitatively and qualitatively a single shot fast spin-echo (SS-FSE) technique with a T2-weighted fast spin-echo (T2-FSE) technique and to determine whether SS-FSE is a valuable alternative to fast SE (FSE) imaging. A total of 41 consecutive patients with brain lesions were retrospectively evaluated. Together with quantitative analysis, contrast-to-noise ratios (CNR), signal-to-noise ratios (SNR), and the percent contrast (%C) were measured for the lesion. Images were evaluated by two radiologists who reached consensus. Visibility (detection), margination and extent of the lesions were rated separately, according to a five-point scale. The mean lesion CNR wets significantly higher on SS-FSE sequences than on fast SE sequences (p=0.0131). The mean lesion %C was also higher on SS-FSE than on T2-FSE sequence (p=0.0222). However, the mean lesion SNR was significantly higher on T2-FSE sequence than on SSFSE sequence (p=0.0222). No significant differences were found in the visibility (detectability) of the lesions between two pulse sequences (p=0.1323). The SSFSE technique is quantitatively superior to T2-FSE for obtaining T2-weighted images of the brain. In comparison with T2-FSE, SS-FSE provides comparable T2-weighted images with sufficient contrast in the evaluation of brain lesions. Our findings suggest that SSFSE may be useful for ill, uncooperative patients, especially for the children patients requiring sedation.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 50 条
  • [21] T2-WEIGHTED MR-IMAGING OF THE CHEST - COMPARISON OF ELECTROCARDIOGRAPH-TRIGGERED CONVENTIONAL AND TURBO SPIN-ECHO AND NONTRIGGERED TURBO SPIN-ECHO SEQUENCES
    HADDAD, JL
    ROFSKY, NM
    AMBROSINO, MM
    NAIDICH, DP
    WEINREB, JC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 325 - 329
  • [22] Fast-recovery fast spin-echo T2-weighted MR imaging: a free-breathing alternative to fast spin-echo in the pediatric abdomen
    I-Hua Huang
    Kathleen H. Emery
    Tal Laor
    Mona Valentine
    Jan Tiefermann
    Pediatric Radiology, 2008, 38 : 675 - 679
  • [23] Fast-recovery fast spin-echo T2-weighted MR imaging: a free-breathing alternative to fast spin-echo in the pediatric abdomen
    Huang, I-Hua
    Emery, Kathleen H.
    Laor, Tal
    Valentine, Mona
    Tiefermann, Jan
    PEDIATRIC RADIOLOGY, 2008, 38 (06) : 675 - 679
  • [24] MR-IMAGING OF THE BRAIN - COMPARISON OF GRADIENT-ECHO AND SPIN-ECHO PULSE SEQUENCES
    PUI, MH
    FOK, ECM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (04) : 959 - 962
  • [25] COMPARISON OF GRADIENT-RECALLED-ECHO AND T2-WEIGHTED SPIN-ECHO PULSE SEQUENCES IN INTRAMEDULLARY SPINAL LESIONS
    KATZ, BH
    QUENCER, RM
    HINKS, RS
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1989, 10 (04) : 815 - 822
  • [26] T2-weighted MR imaging of the liver: Qualitative and quantitative comparison of SPACE MR imaging with turbo spin-echo MR imaging
    Dohan, Anthony
    Gavini, Jean-Philippe
    Place, Vinciane
    Sebbag, Delphine
    Vignaud, Alexandre
    Herbin, Christine
    Hamzi, Lounis
    Boudiaf, Mourad
    Soyer, Philippe
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E655 - E661
  • [27] T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging
    Tamada, T
    Sone, T
    Nagai, K
    Jo, Y
    Gyoten, M
    Imai, S
    Kajihara, Y
    Fukunaga, M
    EUROPEAN RADIOLOGY, 2004, 14 (02) : 318 - 325
  • [28] T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging
    Tsutomu Tamada
    Teruki Sone
    Kiyohisa Nagai
    Yoshimasa Jo
    Masayuki Gyoten
    Shigeki Imai
    Yasumasa Kajihara
    Masao Fukunaga
    European Radiology, 2004, 14 : 318 - 325
  • [29] FAST MRI WITH T2-WEIGHTED SPIN-ECHO SEQUENCES BY VARYING THE FLIP ANGLE
    SCHUBEUS, P
    SANDER, B
    SCHORNER, W
    DEIMLING, M
    TOSCH, U
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (03): : 272 - 276
  • [30] MR Imaging of the Spine at 3.0T with T2-Weighted IDEAL Fast Recovery Fast Spin-Echo Technique
    Ren, Ai-Jun
    Guo, Yong
    Tian, Shu-Ping
    Shi, Li-Jing
    Huang, Min-Hua
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (01) : 44 - 52