Dose painting by dynamic irradiation delivery on an image-guided small animal radiotherapy platform

被引:10
|
作者
Van Hoof, Stefan J. [1 ]
Verde, Joana B. [1 ]
Verhaegen, Frank [1 ]
机构
[1] Maastricht Univ, Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Maastricht, Netherlands
来源
BRITISH JOURNAL OF RADIOLOGY | 2019年 / 92卷 / 1095期
关键词
CONFORMAL RADIOTHERAPY; RADIATION-THERAPY; FILM DOSIMETRY; PERFORMANCE; TECHNOLOGY; COLLIMATOR; SYSTEM;
D O I
10.1259/bjr.20180744
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Using synchronized three-dimensional stage translation and multiangle radiation delivery to improve conformality and homogeneity of radiation delivery to complexly shaped target volumes for precision preclinical radiotherapy. Methods: A CT image of a mouse was used to design irradiation plans to target the spinal cord and an orthotopic lung tumour. A dose painting method is proposed that combines heterogeneous two-dimensional area irradiations from multiple beam directions. For each beam direction, a two-dimensional area was defined based on the projection of the target volume. Each area was divided into many single beam Monte Carlo simulations, based on radiochromic film characterization of a 2.4 mm beam of a commercial precision image-guided preclinical irradiation platform. Beam-on time optimization including all simulated beams from multiple beam directions was used to achieve clinically relevant irradiation objects. Dose painting irradiation plans were compared to irradiation plans using a fixed aperture and rotatable variable aperture collimator. Results: Irradiation plans for the proposed dose painting approach achieved good target coverage, similar dose to avoidance structures in comparison with irradiation using a rotatable variable aperture collimator, and considerably less dose to avoidance volumes in comparison with irradiation using a non-rotatable fixed aperture collimator. Required calculations and beam-on times were considerably longer for the dose painting method. Conclusion: It was shown that the proposed dose painting strategy is a valuable extension to increase the versatility of current generation precision preclinical radiotherapy platforms. More conformal and homogeneous dose delivery may be achieved at the cost of increased radiation planning and delivery duration. Advances in knowledge: More advanced radiation planning for image-guided preclinical radiotherapy platforms can improve target dose conformality and homogeneity with the use of optimized dynamic irradiations with synchronized couch translation. The versatility of these platforms can be increased without hardware modifications.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Development of an image-guided robot for small animal research
    Kazanzides, Peter
    Chang, Jenghwa
    Iordachita, Iulian
    Li, Jack
    Ling, C. Clifton
    Fichtinger, Gabor
    [J]. COMPUTER AIDED SURGERY, 2007, 12 (06) : 357 - 365
  • [32] Evaluation of a Novel Liquid Fiducial Marker, BioXmark®, for Small Animal Image-Guided Radiotherapy Applications
    Brown, Kathryn H.
    Ghita, Mihaela
    Schettino, Giuseppe
    Prise, Kevin M.
    Butterworth, Karl T.
    [J]. CANCERS, 2020, 12 (05)
  • [33] Stereotactic body radiotherapy with image-guided delivery for liver metastasis
    Ricchetti, F.
    Fersino, S.
    Mazzola, R.
    Fiorentino, A.
    Levra, N. Giaj
    Aiello, D.
    Gregucci, F.
    Tebano, U.
    Sicignano, G.
    Naccarato, S.
    Ruggieri, R.
    Alongi, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S770 - S770
  • [34] Imaging Dose and Cancer Risk in Image-Guided Radiotherapy of Cancers
    Zhou, L.
    Bai, S.
    Zhang, Y.
    Ming, X.
    Zhang, Y.
    Deng, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 123 - 123
  • [35] The IMPORT HIGH Image-guided Radiotherapy Study: A Model for Assessing Image-guided Radiotherapy
    Donovan, E. M.
    Harris, E. J.
    Mukesh, M. B.
    Haviland, J. S.
    Titley, J.
    Griffin, C.
    Coles, C. E.
    Evans, P. M.
    [J]. CLINICAL ONCOLOGY, 2015, 27 (01) : 3 - 5
  • [36] An Image-Guided Micro-Radiotherapy System Based On Carbon Nanotube Field Emission Technology for Small Animal Irradiation for Cancer Research
    Wang, S.
    Schreiber, E.
    Calderon-Colon, X.
    Peng, R.
    Sultana, S.
    Zhang, J.
    Zhou, O.
    Chang, S.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [37] Application of dose compensation in image-guided radiotherapy of prostate cancer
    Wu, QW
    Liang, J
    Yan, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06): : 1405 - 1419
  • [38] Imaging Dose and Cancer Risk in Image-Guided Radiotherapy of Cancers
    Zhou, L.
    Bai, S.
    Zhang, Y.
    Deng, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3265 - 3265
  • [39] An Integrated Method for Reproducible and Accurate Image-Guided Stereotactic Cranial Irradiation of Brain Tumors Using the Small Animal Radiation Research Platform
    Baumann, Brian C.
    Benci, Joseph L.
    Santoiemma, Phillip P.
    Chandrasekaran, Sanjay
    Hollander, Andrew B.
    Kao, Gary D.
    Dorsey, Jay F.
    [J]. TRANSLATIONAL ONCOLOGY, 2012, 5 (04): : 230 - 237
  • [40] An orthotopic non-small cell lung cancer model for image-guided small animal radiotherapy platforms
    Iglesias, Venus Sosa
    van Hoof, Stefan J.
    Vaniqui, Ana
    Schyns, Lotte Ejr
    Lieuwes, Natasja
    Yaromina, Ala
    Spiegelberg, Linda
    Groot, Arjan J.
    Verhaegen, Frank
    Theys, Jan
    Dubois, Ludwig
    Vooijs, Marc
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1095):