Intraoperative 3-dimensional imaging of scaphoid fracture reduction and fixation

被引:5
|
作者
Luria, S. [1 ]
Safran, O. [1 ]
Zinger, G. [1 ]
Mosheiff, R. [1 ]
Liebergall, M. [1 ]
机构
[1] Hadassah Hebrew Univ, Dept Orthoped Surg, Med Ctr, IL-91120 Jerusalem, Israel
关键词
Internal fixation; Intraoperative imaging; Scaphoid fracture; Wrist; CT; ISO-C-3D; FOOT;
D O I
10.1016/j.otsr.2014.07.038
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: We examined the clinical benefit of two intraoperative three-dimensional imaging modalities for reduction and fixation of scaphoid fractures. Hypothesis: Our hypothesis was that three dimensional imaging will aid in operative care in comparison with standard fluoroscopy. Methods: In 25 consecutive patients treated for fractures, after satisfactory reduction and fixation was obtained with a single Kirschner wire using fluoroscopy, intraoperative three-dimensional visualization was performed. The quality of fracture reduction, wire position and extrusion of the wire were examined. Results: In two of the 25 cases, after three-dimensional visualization, malreduction of the fracture was seen and the reduction revised. Artifact and the dependency on technologist performance, limited the use of these modalities to locate the wire accurately. Discussion: Diagnosis of malreduction of a scaphoid fracture is possible with 3-dimensional modalities. Utilization of these systems is still limited by technical factors. (C) 2015 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:353 / 357
页数:5
相关论文
共 50 条
  • [22] Imaging for suspected scaphoid fracture
    Ring, David
    Lozano-Calderon, Santiago
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (06): : 954 - 957
  • [23] Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle
    Zix, Juergen
    Lieger, Olivier
    Iizuka, Tateyuki
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (09) : 1758 - 1763
  • [24] Application of 3-Dimensional Printing Technology to Kirschner Wire Fixation of Adolescent Condyle Fracture
    Dong, Zhiwei
    Li, Qihong
    Bai, Shizhu
    Zhang, Li
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (10) : 1970 - 1976
  • [25] Screw Fixation Alone for Scaphoid Fracture Nonunion
    Ernst, Stephen Michael Crowe
    Green, David P.
    Saucedo, James M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2018, 43 (09): : 837 - 843
  • [26] INDICATIONS OF PERCUTANEOUS SCREW FIXATION IN SCAPHOID FRACTURE
    WOZASEK, GE
    MOSER, KD
    UNFALLCHIRURG, 1991, 94 (07): : 342 - 345
  • [27] Intraoperative Assessment of Closed Reduction for Developmental Dislocation of the Hip Using 3-Dimensional Fluoroscopy
    Sachleben, Brant
    Perry, Daniel C.
    Wedge, John
    Kelley, Simon P.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2015, 35 (03) : 246 - 252
  • [28] Use of Intraoperative Computed Tomography in Complex Facial Fracture Reduction and Fixation
    Rabie, Amr
    Ibrahim, Ahmed M. S.
    Lee, Bernard T.
    Lin, Samuel J.
    JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (04) : 1466 - 1467
  • [29] Effect of Intraoperative Three-Dimensional Imaging During the Reduction and Fixation of Displaced Calcaneal Fractures on Articular Congruence and Implant Fixation
    Eckardt, Henrik
    Lind, Marianne
    FOOT & ANKLE INTERNATIONAL, 2015, 36 (07) : 764 - 773
  • [30] A Cadaveric Study on the Accuracy of an Individualized Guiding Template to Assist Scaphoid Fixation Using Computed Tomography and 3-Dimensional Printing
    Guo, Yang
    Tian, Guanglei
    Zlotolow, Dan A.
    Tian, Wen
    Zhong, Wenyao
    Sun, Liying
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (03): : 251.e1 - 251.e6