Penetration of Epiphany, Epiphany Self-Etch, and AH Plus into Dentinal Tubules: A Scanning Electron Microscopy Study

被引:28
|
作者
Shokouhinejad, Noushin [2 ,3 ]
Sabeti, Mohammad [1 ]
Gorjestani, Hedayat [4 ]
Saghiri, Mohammad Ali [5 ]
Lotfi, Mehrdad [6 ,7 ]
Hoseini, Atefeh
机构
[1] Univ So Calif, Sch Dent, Dept Endodont, Los Angeles, CA 90089 USA
[2] Univ Tehran Med Sci, Sch Dent, Dent Res Ctr, Dept Endodont, Tehran, Iran
[3] Iranian Ctr Endodont Res, Tehran, Iran
[4] Kerman Univ Med Sci, Sch Dent, Oral & Dent Dis Res Ctr, Kerman, Iran
[5] Azad Univ, KARC, Sch Dent, Dept Dent Mat, Tehran, Iran
[6] Tabriz Univ Med Sci, Fac Dent, Res Ctr Pharmaceut Nanotechnol, Tabriz, Iran
[7] Tabriz Univ Med Sci, Fac Dent, Dept Endodont, Tabriz, Iran
关键词
AH Plus; Epiphany; scanning electron microscopy; sealer penetration; self-etch; ROOT-CANAL SEALERS; GUTTA-PERCHA; PHYSICOCHEMICAL PROPERTIES; ENDODONTIC SEALERS; CALCIUM HYDROXIDE; DEPTH; IRRIGATION; STRENGTH; LEAKAGE; TEETH;
D O I
10.1016/j.joen.2011.05.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to measure the average depth of dentinal tubule sealer penetration in the middle third of teeth obturated with gutta-percha/AH Plus (Dentsply, DeTrey, Konstanz, Germany), Resilon/Epiphany (Pentron Clinical Technologies, Wallingford, CT), and Resilon/Epiphany self-etch (SE) using scanning electron microscopy (SEM). Methods: The root canals of 36 extracted single-rooted human teeth were prepared and randomly divided into three groups. Obturations were performed with the following filling materials using the lateral compaction technique: group 1, gutta-percha/AH Plus; group 2, Resilon/Epiphany; and group 3, Resilon/Epiphany SE. The specimens were prepared for SEM examination. The average depth of sealer penetration into the dentinal tubules was measured. Data were analyzed by one-way analysis of variance and a post hoc Tukey test. Results: The mean (+/- standard deviation) values for the average depth of sealer penetration in the middle third of the roots were 22.07 +/- 6.92 mu m, 31.56 +/- 6.80 mu m, and 21.50 +/- 9.25 mu m for AH Plus, Epiphany, and Epiphany SE, respectively. The average penetration depth of Epiphany was significantly higher than that of Epiphany SE and AH Plus (P < .05). There was no significant difference between the penetration depth of Epiphany SE and AH Plus (P > .05). Conclusions: It could be concluded that the average penetration for Epiphany into dentinal tubules within the middle third of the roots was significantly deeper than that of Epiphany SE and AH Plus. (J Endod 2011;37:1316-1319)
引用
收藏
页码:1316 / 1319
页数:4
相关论文
共 50 条
  • [21] Influence of the Remnants of Silicone Oil on Penetration of Three Different Sealers into the Dentinal Tubules: A Confocal Laser Scanning Microscopy Study
    Ragab, Mai
    Sharaan, Marwa
    EUROPEAN ENDODONTIC JOURNAL, 2022, 7 (03): : 234 - 240
  • [22] Influence of Irrigation Protocol on Peroxide Penetration into Dentinal Tubules Following Internal Bleaching: A Confocal Laser Scanning Microscopy Study
    Elbahary, Shlomo
    Gitit, Zafrir
    Flaisher-Salem, Nurit
    Azem, Hanaa
    Shemsesh, Hagay
    Rosen, Eyal
    Tsesis, Igor
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2021, 45 (04) : 253 - 258
  • [23] Scanning electron microscopic study of the dentinal tubules in dog canine teeth
    Robb, Larika
    Marx, Jorika
    Steenkamp, Gerhard
    van Heerden, Willie F. P.
    Pretorius, Etheresia
    Boy, Sonja C.
    JOURNAL OF VETERINARY DENTISTRY, 2007, 24 (02) : 86 - 89
  • [24] DENTINAL TUBULES AND ODONTOBLAST PROCESSES - SCANNING ELECTRON-MICROSCOPIC STUDY
    BRANNSTROM, M
    GARBEROGLIO, R
    ACTA ODONTOLOGICA SCANDINAVICA, 1972, 30 (03) : 291 - +
  • [25] Evaluation of the effect of calcium hydroxide paste on sealer penetration into dentinal tubules by confocal laser scanning microscopy
    Kanmaz, Fatma
    Altunbas, Demet
    AUSTRALIAN ENDODONTIC JOURNAL, 2022, 48 (01) : 82 - 90
  • [26] Influence of nano-hydroxyapatite containing desensitizing toothpastes on the sealing ability of dentinal tubules and bonding performance of self-etch adhesives
    Pei, Dandan
    Meng, Yuchen
    Li, Yuncong
    Liu, Jie
    Lu, Yi
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 91 : 38 - 44
  • [27] Obturation of dentinal tubules in the treatment of root sensitivity: A scanning electron microscopic study
    Alassi, F
    Babay, N
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1279 - 1279
  • [28] THE PENETRATION OF SMEAR MATERIAL INTO DENTINAL TUBULES DURING INSTRUMENTATION WITH SURFACE-ACTIVE REAGENTS - A SCANNING ELECTRON-MICROSCOPIC STUDY
    AKTENER, BO
    CENGIZ, T
    PISKIN, B
    JOURNAL OF ENDODONTICS, 1989, 15 (12) : 588 - 590
  • [29] Comparison of total-etch, self-etch, and selective etching techniques on class V composite restorations prepared by Er:YAG laser and bur: a scanning electron microscopy study
    Ozel, Emre
    Tuna, Elif Bahar
    Firatli, Sonmez
    Firatli, Erhan
    MICROSCOPY RESEARCH AND TECHNIQUE, 2016, 79 (10) : 998 - 1004
  • [30] A microleakage study of gutta-percha/AH Plus and Resilon/Real self-etch systems after different irrigation protocols
    Prado, Maira
    Simao, Renata Antoun
    Figueiredo de Almeida Gomes, Brenda Paula
    JOURNAL OF APPLIED ORAL SCIENCE, 2014, 22 (03) : 174 - 179