Method for Evaluation of Trustworthiness of Oscillometric Blood Pressure Measurements

被引:0
|
作者
Koohi, Iraj [1 ]
Ahmad, Saif [1 ]
Batkin, Izmail [1 ]
Groza, Voicu Z. [1 ]
Shirmohammadi, Shervin [1 ]
Dajani, Hilmi R. [1 ]
Petriu, Emil M. [1 ]
机构
[1] Univ Ottawa, Sch Elect Engn & Comp Sci, Ottawa, ON, Canada
关键词
Mean arterial pressure; systolic; diastolic; blood pressure; vessel compliance; oscillometric waveform simulation; PULSE-WAVE VELOCITY; ARTERIAL STIFFNESS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Simple, unobtrusive, and reliable estimation of cardiovascular parameters is a challenge. We present a novel, simple, and noninvasive method called Ratio2 that provides expected ranges for systolic and diastolic blood pressure values (SBP, DBP) estimated by any algorithm, and an evaluation of vessel compliance. Ratio2 was developed in the frame of the oscillometric blood pressure estimation and it exploits the equality between the arterial blood pressure and the cuff pressure at the mean arterial pressure (MAP). This method is based on the observation that the brachial arterial blood pressure pulses, with MAP used as baseline, are characterized by a peak to trough ratio close to 2. This ratio is employed to characterize expected ranges for estimates of systolic and diastolic blood pressure. Any SBP or DBP measurement which is not contained in these intervals is deemed untrustworthy, and it is marked as such. Ratio2 also provides parameters that are used in a mathematical model of arterial blood pressure (BP) to evaluate vessel stiffness. We tested the performance of the Ratio2 method on 150 oscillometric recordings and their corresponding Omron BP estimates obtained from 10 healthy subjects. Results are encouraging, whereby, (a) out-of-range values obtained with the maximum amplitude algorithm (MAA) and the maximum/minimum slope algorithm (MMSA) methods were successfully detected, and (b) linear correlation between age and vessel compliance is -85% (p<0.005). Therefore, we conclude that the proposed work shows promise towards providing noninvasive BP monitors with an inbuilt mechanism for assessing the fidelity of their BP estimates along with an indicator of vessel compliance.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [41] Evaluation of an oscillometric blood pressure monitor for use in anesthetized cats
    Pedersen, KM
    Butler, MA
    Ersboll, AK
    Pedersen, HD
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2002, 221 (05) : 646 - 650
  • [42] Evaluation of lingual oscillometric blood pressure measurement in anaesthetized pigs
    Makepeace, Charles
    Macfarlane, Paul
    Deutsch, Julia
    VETERINARY ANAESTHESIA AND ANALGESIA, 2024, 51 (05) : 482 - 490
  • [43] Evaluation of arterial stiffness and central blood pressure by oscillometric method in normotensive offspring of hypertensive parents
    Yildirim, Cansu Sivrikaya
    Kosger, Pelin
    Akin, Tugcem
    Ucar, Birsen
    CARDIOLOGY IN THE YOUNG, 2022, 32 (06) : 888 - 895
  • [44] Morphological Changes of Pressure Pulses in Oscillometric Non-Invasive Blood Pressure Measurements
    Avbelj, V.
    2014 37TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2014, : 245 - 248
  • [45] Evaluation of an oscillometric blood pressure monitor for use in anesthetized sheep
    Trim, Cynthia M.
    Hofmeister, Erik H.
    Peroni, John F.
    Thoresen, Merrilee
    VETERINARY ANAESTHESIA AND ANALGESIA, 2013, 40 (06) : E31 - E39
  • [46] CHARACTERIZATION OF THE OSCILLOMETRIC METHOD FOR MEASURING INDIRECT BLOOD-PRESSURE
    GEDDES, LA
    VOELZ, M
    COMBS, C
    REINER, D
    BABBS, CF
    ANNALS OF BIOMEDICAL ENGINEERING, 1982, 10 (06) : 271 - 280
  • [48] A new Arterial Blood Pressure Holter based on the oscillometric method
    Vallascas, Rinaldo
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 224 - 228
  • [49] A New Noise Reduction Method for Oscillometric Blood Pressure Measurement
    Choi, Hyun-Seok
    Myoung, Hyoun-Seok
    Lee, Hyo-Ki
    Park, Ho-Dong
    Lee, Kyoung-Joung
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 270 - +
  • [50] A New Algorithm of Blood Pressure Measurement Based on Oscillometric Method
    Luo, Cong
    Li, Tingyu
    Quan, Xiaoli
    Gu, Liangling
    Zhao, Mingfu
    2008 WORLD AUTOMATION CONGRESS PROCEEDINGS, VOLS 1-3, 2008, : 1710 - +