Investigation of diffusion and binding properties of uranium in the diffusive gradients in thin-films technique

被引:2
|
作者
Cheng, Hao [1 ]
Li, Yanying [2 ]
Pouran, Hamid [3 ]
Davison, William [1 ]
Zhang, Hao [1 ]
机构
[1] Univ Lancaster, Lancaster Environm Ctr, Lancaster LA1 4YQ, England
[2] Dalian Maritime Univ, Coll Environm Sci & Engn, Dalian 116023, Liaoning, Peoples R China
[3] Univ Wolverhampton, Fac Sci & Engn, Wolverhampton WV1 1LY, England
关键词
binding; DGT; diffusion; in situ; kinetic; monitoring; speciation; uranium; IN-SITU MEASUREMENT; NATURAL-WATERS; PERFORMANCE-CHARACTERISTICS; MONITORING TOOL; DGT TECHNIQUE; TRACE-METALS; SPECIATION; FERRIHYDRITE; COMPETITION; COMPLEXES;
D O I
10.1071/EN22078
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rationale Diffusive gradients in thin-films (DGT) ha been used for uranium speciation measurements since 2006, but interpretational difficulties have arisen due to uncertainties in the pH dependence of U diffusion coefficients (D) within the diffusive gel. This work tested the hypothesis that differences in measured D values between laboratories are due to methodological artifacts. Methodology The properties of uranium binding and diffusion of U within DGT were systematically investigated at different conditions between pH 3-8 and ionic strength from 1 to 500 mmol L-1. Previous uncertainties were attributed to loss of U by adsorption within the diffusion cell, identified by mass balance calculations, and a binding efficiency dependent on the type of binding gel. Results The diffusion coefficient in an agarose cross-linked polyacrylamide gel measured using Metsorb DGT of 5.26 +/- 0.17 x 10(-6) cm(2) s(-1) agreed well with both values obtained using a pre-conditioned diffusion cell (< 7% difference) and by modelling. The binding efficiencies for Chelex DGT (B-Chelex = 0.86-0.89) and Fe-oxide DGT (BFe-oxide = 0.64 were smaller than for Metsorb DGT (B-Metsorb = 1). No significant differences were found for B-Chelex at different pH. Discussion This work demonstrated that the diffusion coefficient of uranium is independent of pH and the binding gel used, provided the binding efficiency (B) is taken into account. These findings indicate that DGT equipped with either Metsorb or Chelex binding gels should be capable of measuring U for a wide range of environmental conditions provided the appropriate diffusion coefficients and binding efficiencies are used.
引用
收藏
页码:263 / 273
页数:11
相关论文
共 50 条
  • [1] Investigation of trace metal binding properties of lignin by diffusive gradients in thin films
    Hojaji, Elahe
    CHEMOSPHERE, 2012, 89 (03) : 319 - 326
  • [2] Diffusive gradients in thin films technique for uranium measurements in river water
    Li, Weijia
    Li, Chunsheng
    Zhao, Jiujiang
    Cornett, R. Jack
    ANALYTICA CHIMICA ACTA, 2007, 592 (01) : 106 - 113
  • [3] Investigation and application of diffusive gradients in thin-films technique for measuring endocrine disrupting chemicals in seawaters
    Xie, Huaijun
    Chen, Qining
    Chen, Jingwen
    Chen, Chang-Er L.
    Du, Juan
    CHEMOSPHERE, 2018, 200 : 351 - 357
  • [4] Dissolved iodide in marine waters determined with Diffusive Gradients in Thin-films technique
    Gorny, Josselin
    Jardin, Cyrielle
    Diez, Olivier
    Galceran, Josep
    Gourgiotis, Alkiviadis
    Happel, Steffen
    Coppin, Frederic
    Fevrier, Laureline
    Simonucci, Caroline
    Cazala, Charlotte
    ANALYTICA CHIMICA ACTA, 2021, 1177
  • [5] A diffusive gradients in thin-films technique for the assessment of bisphenols desorption from soils
    Guan, Dong-Xing
    Zheng, Jian-Lun
    Luo, Jun
    Zhang, Hao
    Davison, William
    Ma, Lena Q.
    JOURNAL OF HAZARDOUS MATERIALS, 2017, 331 : 321 - 328
  • [6] Speciation measurements of uranium in alkaline waters using diffusive gradients in thin films technique
    Li, Weijia
    Zhao, Jiujiang
    Li, Chunsheng
    Kiser, Stephen
    Cornett, R. Jack
    ANALYTICA CHIMICA ACTA, 2006, 575 (02) : 274 - 280
  • [7] Accuracy of the diffusive gradients in thin-films technique: Diffusive boundary layer and effective sampling area considerations
    Warnken, Kent W.
    Zhang, Hao
    Davison, William
    ANALYTICAL CHEMISTRY, 2006, 78 (11) : 3780 - 3787
  • [8] Chromium (VI) in phosphorus fertilizers determined with the diffusive gradients in thin-films (DGT) technique
    Vogel, Christian
    Hoffmann, Marie C.
    Krueger, Oliver
    Murzin, Vadim
    Caliebe, Wolfgang
    Adam, Christian
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (19) : 24320 - 24328
  • [9] Chromium (VI) in phosphorus fertilizers determined with the diffusive gradients in thin-films (DGT) technique
    Christian Vogel
    Marie C. Hoffmann
    Oliver Krüger
    Vadim Murzin
    Wolfgang Caliebe
    Christian Adam
    Environmental Science and Pollution Research, 2020, 27 : 24320 - 24328
  • [10] Application of New Resin Gels for Measuring Mercury by Diffusive Gradients in a Thin-films Technique
    Pavel Diviš
    Roman Szkandera
    Lukáš Brulík
    Hana Dočekalová
    Peter Matúš
    Marek Bujdoš
    Analytical Sciences, 2009, 25 : 575 - 578