Dissolved iodide in marine waters determined with Diffusive Gradients in Thin-films technique

被引:3
|
作者
Gorny, Josselin [1 ]
Jardin, Cyrielle [1 ]
Diez, Olivier [1 ]
Galceran, Josep [2 ,3 ]
Gourgiotis, Alkiviadis [1 ]
Happel, Steffen [4 ]
Coppin, Frederic [5 ]
Fevrier, Laureline [5 ]
Simonucci, Caroline [1 ,6 ]
Cazala, Charlotte [1 ]
机构
[1] Inst Radioprotect & Surete Nucl IRSN, PSE ENV, SEDRE, LELI, Fontenay Aux Roses, France
[2] Univ Lleida, Dept Quim, Rovira Roure 191, Lleida 25198, Spain
[3] AGROTECNIO CERCA, Rovira Roure 191, Lleida 25198, Spain
[4] TrisKem Int, Bruz, France
[5] Inst Radioprotect & Surete Nucl IRSN, PSE ENV, SRTE, LR2T, Cadarache, France
[6] Inst Radioprotect & Surete Nucl IRSN, PSE ENV, SIRSE, LER NORD, Fontenay Aux Roses, France
关键词
Iodine; Redox speciation; Diffusive gradients in thin-films; Time-series experiment; Laboratory validation; Iodide; Marine waters; IN-SITU MEASUREMENT; FRESH-WATERS; PERFORMANCE-CHARACTERISTICS; ENVIRONMENTAL-SAMPLES; LAYER THICKNESS; BOUNDARY-LAYER; SPECIATION; DGT; BINDING; I-129;
D O I
10.1016/j.aca.2021.338790
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time, Diffusive Gradient in Thin-films (DGT) focuses on the inorganic iodine species iodate (IO3-) and iodide (I-). A silver-doped Cl resin (AgdCl), which is known to selectively accumulate I-, was used to make a binding gel. Laboratory investigations were designed to verify the suitability of the AgdCl-DGT method to measure the total I- concentration in environmental waters. Total recovery of I- was obtained using an elution solution containing 100 mmol L-1 KCN. DGT validation experiments in 10 mmol L-1 NaCl showed linear accumulation of I- over time, contrary to IO3-, thus confirming the selectivity of AgdCl-binding gel. The AgdCl-DGT measurement of total I- concentration was independent of pH (4.5-8.8) and was not impacted by the presence of bicarbonate (1-5 mmol L-1). Finally, the performance of AgdCl-DGT samplers were tested in two continental waters and a synthetic seawater. The AgdCl-DGT samplers measured 27-33% of the total I- concentration in the two continental waters up to 24 h of deployment time, whereas the AgdCl-DGT response retrieved the total I- concentration in seawater up to 72 h (106 +/- 7%). The difference in DGT response was attributed to the low ionic strength of the two continental waters, limiting the application of AgdCl-DGT method to media with higher ionic strength. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Chromium (VI) in phosphorus fertilizers determined with the diffusive gradients in thin-films (DGT) technique
    Vogel, Christian
    Hoffmann, Marie C.
    Krueger, Oliver
    Murzin, Vadim
    Caliebe, Wolfgang
    Adam, Christian
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (19) : 24320 - 24328
  • [2] Chromium (VI) in phosphorus fertilizers determined with the diffusive gradients in thin-films (DGT) technique
    Christian Vogel
    Marie C. Hoffmann
    Oliver Krüger
    Vadim Murzin
    Wolfgang Caliebe
    Christian Adam
    Environmental Science and Pollution Research, 2020, 27 : 24320 - 24328
  • [3] Evaluation of diffusive gradients in thin-films using a Diphonix® resin for monitoring dissolved uranium in natural waters
    Turner, Geraldine S. C.
    Mills, Graham A.
    Burnett, Jonathan L.
    Amos, Sean
    Fones, Gary R.
    ANALYTICA CHIMICA ACTA, 2015, 854 : 78 - 85
  • [4] Development of diffusive gradients in thin-films technique for monitoring polycyclic aromatic hydrocarbons in coastal waters
    Diao, Zishan
    Feng, Guoqin
    Xu, Weikun
    Zhu, Fanping
    Zhang, Yiqiao
    Duan, Jianlu
    Xu, Mengxin
    Zhang, Xue
    Zhang, Xiaohan
    Zhao, Shan
    Wang, Shuguang
    Yuan, Xianzheng
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 471
  • [5] Development and Application of the Diffusive Gradients in Thin-Films Technique for Measuring Psychiatric Pharmaceuticals in Natural Waters
    Fang, Zhou
    Li, Kexin
    Li, Yuan
    Zhang, Hao
    Jones, Kevin C.
    Liu, Xinyu
    Liu, Shengyu
    Ma, Lena Q.
    Luo, Jun
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (19) : 11223 - 11231
  • [6] Development and application of the diffusive gradients in thin films technique for the measurement of total dissolved inorganic arsenic in waters
    Panther, Jared G.
    Stillwell, Kathryn P.
    Powell, Kipton J.
    Downard, Alison J.
    ANALYTICA CHIMICA ACTA, 2008, 622 (1-2) : 133 - 142
  • [7] Validation and Application of the Diffusive Gradients in Thin-Films Technique for In Situ Measurement of β-Blocker Drugs in Waters and Sediments
    Li, Yanying
    Wu, Mingzhe
    Fu, Mengnan
    Tan, Dongqin
    Zhang, Peng
    Zhou, Zhimin
    Li, Xiaoyan
    WATER, 2024, 16 (11)
  • [8] Development and validation of diffusive gradients in thin-films for in situ monitoring of ionic liquids in waters
    Liu, Si-si
    Chen, Shi-bao
    Yue, Yu-bo
    Li, Xiao-hao
    Zhang, Chi
    Ying, Guang-Guo
    Chen, Chang-Er
    ANALYTICAL METHODS, 2024, : 7955 - 7964
  • [9] Selective diffusive gradients in thin-films with molecularly imprinted polymer for fluoroquinolone antibiotics in waters
    Liu, Si-Si
    Li, Jin-Ling
    Ge, Lin-Ke
    Li, Cai-Lin
    Zhao, Jian-Liang
    Zhang, Qian-Qian
    Ying, Guang-Guo
    Chen, Chang-Er
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 790
  • [10] Diffusive gradients in thin-films (DGT) for in situ measurement of neonicotinoid insecticides (NNIs) in waters
    Xiong, Junwu
    Pu, Chang
    Qian, Zhe
    Yi, Jiapei
    Wang, Kang
    Zhang, Chi
    Liu, Wei
    Chen, Wei
    Xu, Li
    Qi, Shihua
    Zhang, Zulin
    Zhang, Hao
    Jones, Kevin C.
    WATER RESEARCH, 2025, 269