Static-digital overcurrent relays permit enhanced protection

被引:1
|
作者
Bailey, B [1 ]
Jakominich, D [1 ]
机构
[1] Siemens Power Transmiss & Distribut LLC, Raleigh, NC 27626 USA
关键词
D O I
10.1109/ICPS.1998.692529
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Multi-function static overcurrent relays employing digital technology have functionality that permits improved and expanded protection in many applications. While a relay is normally selected for the required overcurrent and ground fault protection, effective utilization of additional available functions can provide added security without significant additional cost. This paper describes an application for a refinery power system that uses the directional overcurrent elements and reverse interlocking between the Main, Tie and Feeder relays for a dual source-normally closed tie system. This scheme provides fast tripping for bus faults, which has several advantages over traditional bus differential relaying. This paper also describes a ground fault protection scheme to detect feeder grounds on a high resistance grounded system.
引用
收藏
页码:25 / 32
页数:4
相关论文
共 50 条
  • [21] GENERATOR GROUND FAULT PROTECTION USING OVERCURRENT, OVERVOLTAGE, AND UNDERVOLTAGE RELAYS
    GRIFFIN, CH
    POPE, JW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (12): : 4490 - 4501
  • [22] Optimal coordination of directional overcurrent protection relays using hybrid optimizer
    Habib, Kashif
    Wadood, Abdul
    Wei, Tang
    Khan, Shahbaz
    Xing, Xu
    ENGINEERING RESEARCH EXPRESS, 2024, 6 (02):
  • [23] Overcurrent protection of AC microgrids using mixed characteristic curves of relays
    Alam, Mahamad Nabab
    COMPUTERS & ELECTRICAL ENGINEERING, 2019, 74 : 74 - 88
  • [24] Protection Coordination of Directional Overcurrent Relays Considering Fault Current Direction
    Sharaf, Hebatallah Mohamed
    Zeineldin, H. H.
    Ibrahim, Doaa Khalil
    El Zahab, Essam El Din Abo
    2014 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT EUROPE), 2014,
  • [25] Optimal computation of distance relays second zone timing in a mixed protection scheme with directional overcurrent relays
    Pérez, LG
    Urdaneta, AJ
    IEEE TRANSACTIONS ON POWER DELIVERY, 2001, 16 (03) : 385 - 388
  • [26] A New Genetic Algorithm Method for Optimal Coordination of Overcurrent Relays in a Mixed Protection Scheme with Distance Relays
    Abyanch, Hossein Askarian
    Kamangar, Somayeh Sadat Hashemi
    Razavi, Farzad
    Chabanloo, Reza Mohammadi
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 51 - +
  • [27] A Primer On Pilot Protection With Digital Relays
    Saygin, Sinan
    Voloh, Ilia
    Zhang, Zhiying
    2015 68TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2015, : 866 - 880
  • [28] Enhanced Combined Protection Scheme Using Dual Setting Directional Overcurrent and Distance Relays Considering Severe Line Contingencies
    Tiwari, Raghvendra
    Singh, Ravindra Kumar
    Choudhary, Niraj Kumar
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023,
  • [29] Enhanced Back Controlled Phase Fault and Earth Fault Busbar Protection Scheme using Overcurrent and Earth Fault Relays
    Obuliraj D.
    Loganathan P.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (03) : 1025 - 1032
  • [30] Protection coordination for networked microgrids using single and dual setting overcurrent relays
    Alam, Mahamad Nabab
    Gokaraju, Ramakrishna
    Chakrabarti, Saikat
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (14) : 2818 - 2828