Influence of the granulation grade on the concentration of suspended solids in the effluent of a pilot scale sequencing batch reactor operated with aerobic granular sludge

被引:46
|
作者
Rocktaeschel, T. [1 ]
Klarmann, C. [2 ]
Ochoa, J. [3 ]
Boisson, P. [3 ]
Sorensen, K. [4 ]
Horn, H. [5 ,6 ]
机构
[1] GFM Consulting Engineers, D-80799 Munich, Germany
[2] Tech Univ Munich, Chair Urban Water Syst Engn, D-85748 Garching, Germany
[3] Veolia Environm Res & Innovat, F-78608 Maisons Laffitte, France
[4] Veolia Water Tech Dept, F-94410 St Maurice, France
[5] Karlsruhe Inst Technol, Chair Water Chem & Water Technol, D-76131 Karlsruhe, Germany
[6] DVGW Res Lab Water Chem & Water Technol, D-76131 Karlsruhe, Germany
关键词
Activated sludge granulation; Anaerobic mixing phase; Municipal wastewater treatment; Granule content; Suspended solids; WASTE-WATER; PHOSPHORUS REMOVAL; NITROGEN REMOVAL; SELECTION; BIOFILM; NITRIFICATION; TEMPERATURE; METABOLISM; ORGANISMS; BACTERIA;
D O I
10.1016/j.seppur.2015.01.013
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The operation of aerobic granular sludge reactors with a completely granulated sludge bed is often associated with effluent suspended solids concentrations above the required limits. In this work it can be shown that the amount of aerobic granules on the total biomass concentration is a key operation tool to control the suspended solids effluent concentration. Low effluent concentrations could be achieved only when the granule content was below 80%. A pilot scale reactor with a working volume of 4 m(3) was used to treat municipal wastewater with aerobic granules and was operated for 247 days. The chosen sequential batch operation consisted of five phases: a short influent, anaerobic mixing, aeration, settling and effluent. The anaerobic mixing is innovative as it provides the same conditions for all granules. Additionally, by choosing an anaerobic mixing step the activated sludge granulation can be applied independently to the reactor geometry. Total suspended solids concentrations of 12 g(TSS)/L in the reactor and effluent suspended solids concentration below 50 mg(TSS)/L could be achieved. During the reactor startup a high hydraulic selection pressure was not required to induce the granule formation. Hence, a complete nitrification was achieved already during start up. The added phosphorus was completely removed biologically by the granules. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:234 / 241
页数:8
相关论文
共 50 条
  • [41] PILOT SCALE AEROBIC SEQUENCING BATCH REACTOR FOR PIG WASTE TREATMENT
    WONG, SH
    CHOI, CC
    JOURNAL OF THE INSTITUTION OF WATER AND ENVIRONMENTAL MANAGEMENT, 1989, 3 (01): : 75 - 81
  • [42] Selenite reduction and ammoniacal nitrogen removal in an aerobic granular sludge sequencing batch reactor
    Nancharaiah, Y. V.
    Sarvajith, M.
    Lens, P. N. L.
    WATER RESEARCH, 2018, 131 : 131 - 141
  • [43] Cultivation of polyhydroxybutyrate-rich aerobic CD granular sludge in a sequencing batch reactor
    Wang, J.
    Yu, H. Q.
    Leading-Edge Strategies and Technologies for Sustainable Urban Water Management, 2006, 6 (06): : 81 - 87
  • [44] Effect of Mn2+ augmentation on reinforcing aerobic sludge granulation in a sequencing batch reactor
    Huang, Lihui
    Yang, Tao
    Wang, Weiliang
    Zhang, Bo
    Sun, Yuanyuan
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2012, 93 (06) : 2615 - 2623
  • [45] Effect of Mn2+ augmentation on reinforcing aerobic sludge granulation in a sequencing batch reactor
    Lihui Huang
    Tao Yang
    Weiliang Wang
    Bo Zhang
    Yuanyuan Sun
    Applied Microbiology and Biotechnology, 2012, 93 : 2615 - 2623
  • [46] Effective sludge activation in a sequencing batch reactor (SBR) towards aerobic granular sludge (AGS) technology
    Setianingsih, Nanik Indah
    Hadiyanto
    Budihardjo, Mochamad Arief
    Yuliasni, Rustiana
    Vistanty, Hanny
    Budiono
    Sudarno
    Warsito, Budi
    DESALINATION AND WATER TREATMENT, 2024, 320
  • [47] Optimizing sequencing batch reactor (SBR) reactor operation for treatment of dairy wastewater with aerobic granular sludge
    Wichern, M.
    Luebken, M.
    Horn, H.
    WATER SCIENCE AND TECHNOLOGY, 2008, 58 (06) : 1199 - 1206
  • [48] Granulation of activated sludge in a pilot-scale sequencing batch reactor for the treatment of low-strength municipal wastewater
    Ni, Bing-Jie
    Xie, Wen-Ming
    Liu, Shao-Gen
    Yu, Han-Qing
    Wang, Ying-Zhe
    Wang, Gan
    Dai, Xian-Liang
    WATER RESEARCH, 2009, 43 (03) : 751 - 761
  • [49] Startup of pilot-scale aerobic granular sludge reactor by stored granules
    Liu, QS
    Liu, Y
    Tay, STL
    Show, KY
    Ivanov, V
    Benjamin, M
    Tay, JH
    ENVIRONMENTAL TECHNOLOGY, 2005, 26 (12) : 1363 - 1369
  • [50] Effect of hexavalent chromium on extracellular polymeric substances of granular sludge from an aerobic granular sequencing batch reactor
    Wang, Zichao
    Gao, Mengchun
    Wang, Sen
    Xin, Yanjun
    Ma, Dong
    She, Zonglian
    Wang, Zhe
    Chang, Qingbo
    Ren, Yun
    CHEMICAL ENGINEERING JOURNAL, 2014, 251 : 165 - 174