Local plate/rod descriptors of 3D trabecular bone micro-CT images from medial axis topologic analysis

被引:17
|
作者
Peyrin, Francoise [1 ,2 ,3 ,4 ,5 ,6 ]
Attali, Dominique [7 ]
Chappard, Christine [8 ,9 ]
Benhamou, Claude Laurent [8 ]
机构
[1] CNRS, CREATIS, UMR 5220, F-69621 Villeurbanne, France
[2] INSERM, U630, F-69621 Villeurbanne, France
[3] Insa Lyon, F-69621 Villeurbanne, France
[4] Univ Lyon 1, F-69621 Villeurbanne, France
[5] Univ Lyon, F-69621 Villeurbanne, France
[6] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[7] CNRS, GIPSA Lab, UMR 5216, F-38402 St Martin Dheres, France
[8] INSERM, U658, F-45032 Orleans 1, France
[9] Univ Paris 07, CNRS, UMR7052, B20A, F-75010 Paris, France
关键词
three-dimensional image analysis; x-ray computed tomography; SKELETON GRAPH ANALYSIS; CANCELLOUS BONE; ARCHITECTURE; QUANTIFICATION; OSTEOARTHRITIS; DECOMPOSITION; THICKNESS; MODELS; WOMEN; SPINE;
D O I
10.1118/1.3447728
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Trabecular bone microarchitecture is made of a complex network of plate and rod structures evolving with age and disease. The purpose of this article is to propose a new 3D local analysis method for the quantitative assessment of parameters related to the geometry of trabecular bone microarchitecture. Methods: The method is based on the topologic classification of the medial axis of the 3D image into branches, rods, and plates. Thanks to the reversibility of the medial axis, the classification is next extended to the whole 3D image. Finally, the percentages of rods and plates as well as their mean thicknesses are calculated. The method was applied both to simulated test images and 3D micro-CT images of human trabecular bone. Results: The classification of simulated phantoms made of plates and rods shows that the maximum error in the quantitative percentages of plate and rods is less than 6% and smaller than with the structure model index (SMI). Micro-CT images of human femoral bone taken in osteoporosis and early or advanced osteoarthritis were analyzed. Despite the large physiological variability, the present method avoids the underestimation of rods observed with other local methods. The relative percentages of rods and plates were not significantly different between osteoarthritis and osteoporotic groups, whereas their absolute percentages were in relation to an increase of rod and plate thicknesses in advanced osteoarthritis with also higher relative and absolute number of nodes. Conclusions: The proposed method is model-independent, robust to surface irregularities, and enables geometrical characterization of not only skeletal structures but entire 3D images. Its application provided more accurate results than the standard SMI on simple simulated phantoms, but the discrepancy observed on the advanced osteoarthritis group raises questions that will require further investigations. The systematic use of such a local method in the characterization of trabecular bone samples could provide new insight in bone microarchitecture changes related to bone diseases or to those induced by drugs or therapy. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3447728]
引用
收藏
页码:4364 / 4376
页数:13
相关论文
共 50 条
  • [21] FEA Based on 3D Micro-CT Images of Mesoporous Engineered Hydrogels
    Siad, L.
    Jing, J.
    Braux, J.
    Dubus, M.
    Velard, F.
    Laurent-Maquin, D.
    Gangloff, S. C.
    Kerdjoudj, H.
    Rahouadj, R.
    Schmidt, J. -F.
    Ganghoffer, J. -F.
    [J]. ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2015, 5 (06) : 885 - 890
  • [22] 3D micro-CT images of ossicles destroyed by middle ear cholesteatoma
    Park, K
    Moon, SK
    Cho, MJ
    Won, YY
    Baek, MG
    [J]. ACTA OTO-LARYNGOLOGICA, 2004, 124 (04) : 403 - 407
  • [23] The impact of scan resolution on 3D quantitative analysis of cortical bone porosity by micro-CT
    Turinsky, AL
    Cooper, DML
    Hallgrimsson, B
    Sensen, CW
    [J]. FASEB JOURNAL, 2004, 18 (05): : A785 - A785
  • [24] Classification of micro-CT images using 3D characterization of bone canal patters in human osteogenesis imperfecta
    Abidin, Anas Z.
    Jameson, John
    Molthen, Robert
    Wismueller, Axel
    [J]. MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS, 2017, 10134
  • [25] Bone microarchitectural assessment in male idiopathic osteoporosis by 3D micro-CT
    Garcia-Miguel, J.
    Wright, A. C.
    Perez Edo, L.
    Marinoso, M.
    Blanche, J.
    Carbonell, J.
    Wehrli, F. W.
    [J]. BONE, 2007, 40 (06) : S259 - S260
  • [26] Bone microarchitectural assessment in male idiopathic osteoporosis by 3D micro-CT
    Garcia-Miguel, J.
    Wright, A.
    Perez-Edo, L.
    Blanch, J.
    Marinoso, M.
    Ciria, M.
    Rotes, D.
    Carbonell, J.
    Wehrli, F.
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2007, 80 : S161 - S161
  • [27] Bone microarchitectural changes in rheumatoid arthritis assessed by 3D micro-CT
    Garcia-Miguel, J.
    Wright, A.
    Perez-Edo, L.
    Blanch, J.
    Marinoso, M.
    Ciria, M.
    Rotes, D.
    Carbonell, J.
    Wehrli, F.
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2007, 80 : S160 - S161
  • [28] Micro-CT analysis of 3D printed provisional crowns fitting
    Alsubaiy, Ebrahim Fihaid
    [J]. TECHNOLOGY AND HEALTH CARE, 2023, 31 (01) : 259 - 268
  • [29] Bone Substitutes Scaffold in Human Bone: Comparative Evaluation by 3D Micro-CT Technique
    Bedini, Rossella
    Pecci, Raffaella
    Meleo, Deborah
    Campioni, Ilaria
    [J]. APPLIED SCIENCES-BASEL, 2020, 10 (10):
  • [30] Utilization of micro-CT to measure 3D changes in trabecular bone structure in estrogen deficient rats treated with estrogen and raloxifene: An interim analysis.
    Lane, NE
    Majumdar, S
    Lotz, J
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (04) : 806 - 806