Photon Counting CT of the liver with dual-contrast enhancement

被引:6
|
作者
Muenzel, Daniela [1 ]
Proksa, Roland [2 ]
Daerr, Heiner [2 ]
Fingerle, Alexander A. [1 ]
Pfeiffer, Franz [1 ,3 ,4 ]
Rummeny, Ernst J. [1 ]
Noel, Peter B. [1 ,3 ,4 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Diagnost & Intervent Radiol, D-80290 Munich, Germany
[2] Philips Res, Res Labs, Hamburg, Germany
[3] Tech Univ Munich, Chair Biomed Phys, Garching, Germany
[4] Tech Univ Munich, Dept Phys, Inst Med Engn, Garching, Germany
关键词
Photon Counting CT; Liver Imaging; Dual Contrast; Material Decomposition; HEPATOCELLULAR-CARCINOMA; PHASES; METASTASES;
D O I
10.1117/12.2216391
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The diagnostic quality of photon counting computed tomography (PCCT) is one the unexplored areas in medical imaging; at the same time, it seems to offer the opportunity as a fast and highly sensitive diagnostic tool. Today, conventional computed tomography (CT) is the standard imaging technique for diagnostic evaluation of the parenchyma of the liver. However, considerations on radiation dose are still an important factor in CT liver imaging, especially with regard to multi-phase contrast enhanced CT. In this work we report on a feasibility study for multi-contrast PCCT for simultaneous liver imaging at different contrast phases. PCCT images of the liver were simulated for a contrast-enhanced examination performed with two different contrast agents (CA), iodine (CA 1) and gadolinium (CA 2). PCCT image acquisition was performed at the time point with portal venous contrast distribution of CA 1 and arterial contrast phase for CA 2. Therefore, a contrast injection protocol was planned with sequential injection of CA 1 and CA 2 to provide a time dependent difference in contrast distribution of both CAs in the vessels and parenchyma of the liver. Native, arterial, and portal venous contrast enhanced images have been calculated based on the spectral separation of PCCT. In simulated PCCT images, we were able to differentiate between the tissue enhancement of CA 1 and CA 2. The distribution of both CA within the parenchyma of the liver was illustrated with perfusion maps for CA 1 and CA 2. In addition, virtual non contrast enhanced image were calculated. In conclusion, multi-phase PCCT imaging of the liver based on a single scan is a novel approach for spectral PCCT imaging, offering detailed contrast information in a single scan volume and a significant reduction of radiation dose.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Dual Energy CT Kidney Stone Differentiation in Photon Counting Computed Tomography
    Gutjahr, R.
    Polster, C.
    Henning, A.
    Kappler, S.
    Leng, S.
    McCollough, C. H.
    Sedlmair, M. U.
    Schmidt, B.
    Krauss, B.
    Flohr, T. G.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [42] Hepatic dual-contrast CT imaging: slow triple kVp switching CT with CNN-based sinogram completion and material decomposition
    Cao, Wenchao
    Shapira, Nadav
    Maidment, Andrew
    Daerr, Heiner
    Noel, Peter B.
    JOURNAL OF MEDICAL IMAGING, 2022, 9 (01)
  • [43] High-Contrast K-Edge CT by CdTe Photon Counting Detector
    Ashitomi, K.
    Imura, Y.
    Mimura, H.
    Aoki, T.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [44] The potential of photon-counting CT for quantitative contrast-enhanced imaging in radiotherapy
    Simard, Mikael
    Lapointe, Andreanne
    Lalonde, Arthur
    Bahig, Houda
    Bouchard, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (11):
  • [45] Impact of energy threshold on material quantification of contrast agents in photon-counting CT
    Rajagopal, Jayasai R.
    Sahbaee, Pooyan
    Abadi, Ehsan
    Negussie, Ayele H.
    Pritchard, William F.
    Wood, Bradford J.
    Jones, Elizabeth C.
    Samei, Ehsan
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [46] INVESTIGATION OF CONTRAST ENHANCEMENT IN CT OF THE LIVER - THE NEED FOR IMPROVED METHODS
    DODD, GD
    BARON, RL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) : 643 - 645
  • [47] CORRELATION OF CT CONTRAST ENHANCEMENT WITH IODINE CONCENTRATION IN RABBIT LIVER
    VIOLANTE, MR
    DEAN, PB
    BURGENER, FA
    FISCHER, HW
    INVESTIGATIVE RADIOLOGY, 1978, 13 (05) : 394 - 394
  • [48] Dual-Contrast Dynamic MRI-DOT for Small Animal Imaging
    Thayer, David
    Unlu, Mehmet Burcin
    Lin, Yuting
    Yan, Kevin
    Nalcioglu, Orhan
    Gulsen, Gultekin
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (01) : 61 - 69
  • [49] TECHNIQUE OF DUAL-CONTRAST ARTHROGRAPHY OF KNEE JOINT WITH HORIZONTAL BEAM OF RADIATION
    CZEKALA, Z
    POLISH REVIEW OF RADIOLOGY AND NUCLEAR MEDICINE, 1966, 30 (01): : 10 - &
  • [50] Concurrent Dual-Contrast Enhancement Using Fe3O4 Nanoparticles to Achieve a CEST Signal Controllability
    Hu, Feixiang
    Wang, Dan
    Ma, Xiaowen
    Hu, Tingdan
    Yue, Yali
    Tang, Wei
    Wu, PuYe
    Tong, Tong
    Peng, Weijun
    ACS OMEGA, 2023, 8 (27): : 24153 - 24164