Harmonic analysis of the cone flicker ERG of rabbit

被引:7
|
作者
Qian, Haohua [1 ,2 ,3 ]
Alexander, Kenneth R. [1 ,4 ,5 ]
Ripps, Harris [1 ,2 ,6 ]
机构
[1] Univ Illinois, Dept Ophthalmol & Visual Sci, Chicago, IL 60612 USA
[2] Univ Illinois, Dept Physiol & Biophys, Chicago, IL 60612 USA
[3] Univ Illinois, Dept Biol Sci, Chicago, IL 60612 USA
[4] Univ Illinois, Dept Psychol, Chicago, IL 60612 USA
[5] Univ Illinois, Dept Bioengn, Chicago, IL 60612 USA
[6] Marine Biol Lab, Woods Hole, MA 02543 USA
关键词
electroretinogram; flicker ERG; rabbit; cone pathway; pharmacology; sinusoidal stimuli; frequency response; MAMMALIAN RETINA; IN-VIVO; B-WAVE; ELECTRORETINOGRAM; RESPONSES; AMPLITUDE; TOXICITY; KINETICS; ROD;
D O I
10.1016/j.exer.2010.10.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Harmonic analysis was used to characterize the rabbit flicker ERG elicited by sinusoidally modulated full-field stimuli under light-adapted conditions. The frequency-response function for fundamental amplitude, derived from Fourier analysis of the ERG waveforms, exhibited two limbs, with an amplitude minimum at approximately 30 Hz, and a high-frequency region peaking at around 45 Hz and extending to more than 100 Hz at higher adapting levels. At low frequencies (< 20 Hz), the fundamental response amplitude was independent of mean luminance (Weber law behavior), whereas the response amplitude at high stimulus frequencies varied nonlinearly with mean luminance. At low frequencies, intravitreal administration of L-AP4, which blocks ON-pathway activity, reduced the fundamental response amplitude and produced a phase shift. On the other hand, PDA, which reduces OFF-pathway activity, had a minimal effect on both the response amplitude and phase at low frequencies. At high frequencies, L-AP4 increased the fundamental response amplitude at low mean luminances, whereas PDA had only a small effect on amplitude and phase. Both pharmacologic agents removed the minimum in the amplitude-frequency function as well as the abrupt change in phase at stimulus frequencies near 30 Hz. The results suggest that there is a nonlinear interaction between ON- and OFF-pathway activity over the entire stimulus frequency range examined in this study. These findings provide a basis for formulating protocols to evaluate the effect of pharmacologic agents and/or disease on the cone flicker ERG of rabbit. Published by Elsevier Ltd.
引用
收藏
页码:811 / 817
页数:7
相关论文
共 50 条
  • [31] Flicker ERG evidence that Sprague Dawley and Brown Norway rats have different cone-mediated responses
    Rosolen, SG
    Chalier, C
    Rigaudière, F
    Lachapelle, P
    Le Gargasson, JF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U304 - U304
  • [32] SENSITIVITY OF FULL-FIELD CONE ERG IMPLICIT TIME TO REDUCTIONS IN RETINAL ILLUMINATION - DEPENDENCE ON FLICKER FREQUENCY
    REMULLA, JFC
    SANDBERG, MA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S447 - S447
  • [33] APPLICATION OF HARMONIC-ANALYSIS TO RESIDUAL BRIGHTNESS FLICKER
    SWISHER, CW
    MANDES, EJ
    PERCEPTUAL AND MOTOR SKILLS, 1973, 37 (01) : 191 - 198
  • [34] ERG Critical Flicker Frequency Assessment in Humans
    Bowles, Kristen E.
    Kraft, Timothy W.
    RETINAL DEGENERATIVE DISEASES, 2012, 723 : 503 - 509
  • [35] ERG responses to contrast and flicker in human infants
    Rasengane, TA
    Allen, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1604 - 1604
  • [36] Diopsys Flicker ERG findings in Retinal Vasculitis
    Zaidi, Moosa
    Ghoraba, Hashem
    Hwang, Jaclyn Joyce
    Or, Christopher
    Lajevardi, Sherin
    Regenold, Jonathan
    Mobasserian, Azadeh
    Akhavanrezayat, Amir
    Park, SungWho
    Karaca, Irmak
    Khan, Youan Hasan
    Yasar, Cigdem
    Uludag, Gunay
    Ngoc Than
    Hassan, Muhammad
    Quan Dong Nguyen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [37] Evaluation of correlation between Diopsys® NOVA™ fixed-luminance flicker ERG and Diagnosys® Espion 2™ flicker ERG parameters
    Jonathan Regenold
    Hien Luong Doan
    Hashem Ghoraba
    Hassan Khojasteh
    Jaclyn Joyce Jaclyn Hwang
    Negin Yavari
    Amir Akhavanrezayat
    Ngoc Trong Tuong Than
    Anthony Huy Dinh Le
    Muhammad Sohail Halim
    Quan Dong Nguyen
    Documenta Ophthalmologica, 2023, 146 : 257 - 266
  • [38] Photopic ERG and flicker ERG in evaluation of macular function in patients with retinitis pigmentosa
    Scipioni, L
    Rispoli, E
    Vingolo, EM
    Iacobelli, L
    Palitto, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S21 - S21
  • [39] Evaluation of correlation between Diopsys® NOVA™ fixed-luminance flicker ERG and Diagnosys® Espion 2™ flicker ERG parameters
    Regenold, Jonathan
    Doan, Hien Luong
    Ghoraba, Hashem
    Khojasteh, Hassan
    Jaclyn Hwang, Jaclyn Joyce
    Yavari, Negin
    Akhavanrezayat, Amir
    Than, Ngoc Trong Tuong
    Le, Anthony Huy Dinh
    Halim, Muhammad Sohail
    Nguyen, Quan Dong
    DOCUMENTA OPHTHALMOLOGICA, 2023, 146 (03) : 257 - 266
  • [40] Clinical flicker ERG: Noise analysis and signal extraction with cycle-by-cycle analysis.
    Jamison, JA
    Sieving, PA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S17 - S17