Model based water management diagnosis in polymer electrolyte membrane fuel cell

被引:20
|
作者
Esmaili, Qadir [1 ]
Nimvari, Majid Eshagh [1 ]
Jouybari, Nima Fallah [2 ]
Chen, Yong-Song [3 ,4 ]
机构
[1] Amol Univ Special Modern Technol, Fac Engn, Amol, Iran
[2] Lulea Univ Technol, Div Fluid Mech, S-97187 Lulea, Sweden
[3] Natl Chung Cheng Univ, Adv Inst Mfg High Tech Innovat, 168 Univ Rd, Minhsiung Township 62102, Chiayi, Taiwan
[4] Natl Chung Cheng Univ, Dept Mech Engn, 168 Univ Rd, Minhsiung Township 62102, Chiayi, Taiwan
关键词
Polymer electrolyte membrane fuel cell; Water management; Diagnosis; Segmented model; PRESSURE-DROP; FLOW CHANNELS; 2-PHASE FLOW; GAS-FLOW; EXCHANGE; TRANSPORT; CATHODE; DEGRADATION; UNIFORMITY; HUMIDITY;
D O I
10.1016/j.ijhydene.2020.04.031
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Water management diagnosis in polymer electrolyte membrane fuel cell is of great importance. The water produced in the fuel cell affects its performance and lifetime through the current distribution and the two phase flow pattern in the channel. The aim of the present study is to modify a segmented model in order to investigate a model-based water management diagnosis at different operating conditions. Simulations are conducted in three current densities: low (0.2 A/cm(2)), medium (0.6 A/cm(2)) and high (1 A/cm(2)), four temperatures ranged from 40 to 70, two stoichiometries (2 and 3) and four inlet humidities 25%, 50%,75% and 100%). The results show that at fully saturation inlet condition, there is a uniform local current density for all three considered current densities. Also, two-phase pressure drop and output voltage have similar trends. Hence two phase pressure drop can be considered as a suitable criterion for water management diagnosis. At inlet humidities less than 50%, non-uniformity of local current density increases that leads to reduction of less than 50%, non-uniformity of local current density increases that leads to reduction of output voltage, especially at high current density. Generally, for non-saturated inlet condition, two phase pressure drop and output voltage may show different trends. Therefore, two-phase pressure drop can be used only as a criterion for the formation of water and not for water management diagnosis. (C) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:15618 / 15629
页数:12
相关论文
共 50 条
  • [21] Probing Liquid Water Profile in the Polymer Electrolyte Fuel Cell Membrane
    Mukherjee, P. P.
    Springer, T. E.
    Mukundan, R.
    Hussey, D. S.
    Jacobson, D. L.
    Arif, M.
    Borup, R. L.
    PROTON EXCHANGE MEMBRANE FUEL CELLS 8, PTS 1 AND 2, 2008, 16 (02): : 1027 - +
  • [22] Experimental investigation of water droplet emergence in a model polymer electrolyte membrane fuel cell microchannel
    Wu, T. C.
    Djilali, N.
    JOURNAL OF POWER SOURCES, 2012, 208 : 248 - 256
  • [23] A Fuzzy Model to Manage Water in Polymer Electrolyte Membrane Fuel Cells
    Abel Rubio, Gomer
    Edixon Agila, Wilton
    PROCESSES, 2021, 9 (06)
  • [24] Diagnosis of Membrane Chemical Degradation For Health Management of Polymer Electrolyte Fuel Cells
    Low, Derek
    Jackson, Lisa
    Dunnett, Sarah
    2019 IEEE INTERNATIONAL CONFERENCE ON PROGNOSTICS AND HEALTH MANAGEMENT (ICPHM), 2019,
  • [25] Composite membrane for polymer electrolyte membrane fuel cell
    Kim, CS
    Yang, TH
    Kwak, SH
    Yoon, KH
    SOLID STATE IONICS: THE SCIENCE AND TECHNOLOGY OF IONS IN MOTION, 2004, : 127 - 134
  • [26] Distributed parameter model-based control of water activity and concentration of reactants in a polymer electrolyte membrane fuel cell
    Sarmiento-Carnevali, Maria
    Serra, Maria
    Batlle, Caries
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (42) : 26389 - 26407
  • [27] Improvement and Revision of Polymer Electrolyte Membrane Fuel Cell Dynamic Model
    Niknam, Taher
    Taheri, Seyed Iman
    Mohammdi, Mohammad
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2010, 38 (12) : 1353 - 1369
  • [28] Numerical Model of Polymer Electrolyte Membrane Fuel Cell Startup and Shutdown
    Maranzana, G.
    Lamibrac, A.
    Dillet, J.
    Abbou, S.
    Didierjean, S.
    Lottin, O.
    POLYMER ELECTROLYTE FUEL CELLS 13 (PEFC 13), 2013, 58 (01): : 1619 - 1630
  • [29] CATHODE CATALYST LAYER MODEL FOR POLYMER ELECTROLYTE MEMBRANE FUEL CELL
    Kamarajugadda, Sai
    Mazumder, Sandip
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 6, PTS A AND B, 2013, : 789 - 798
  • [30] Evaluation of Two Water Transports through Electrolyte Membrane of Polymer Electrolyte Fuel Cell Based on Water Visualization and Current Measurement
    Nishida, K.
    Hosotani, T.
    Asa, M.
    FUEL CELLS, 2019, 19 (01) : 60 - 70