Breaking the Stokes-anti-Stokes symmetry in Raman heterodyne detection of magnetic-resonance transitions

被引:5
|
作者
Neuhaus, R [1 ]
Sellars, MJ [1 ]
Bingham, SJ [1 ]
Suter, D [1 ]
机构
[1] Univ Dortmund, Fachbereich Phys, D-44221 Dortmund, Germany
来源
PHYSICAL REVIEW A | 1998年 / 58卷 / 06期
关键词
D O I
10.1103/PhysRevA.58.4961
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Coherent Raman scattering can generate Stokes and anti-Stokes fields of comparable intensities. When the Raman shift is due to a magnetic resonance transition (usually in the MHz to GHz range), the Raman fields are generally detected by optical heterodyne detection, using the excitation laser as the local oscillator. In this case, the two sidebands generate beat signals at the same frequency and are therefore indistinguishable. Separation of the two contributions becomes possible, however, by superheterodyne detection with a frequency-shifted optical local oscillator. We compare the two scattering processes, and show how the symmetry between them can be broken in Pr3+:YAlO3. [S1050-2947(98)08412-1].
引用
收藏
页码:4961 / 4966
页数:6
相关论文
共 50 条
  • [21] Heterodyne polarization coherent anti-Stokes Raman scattering microscopy
    Lu, Fake
    Zheng, Wei
    Huang, Zhiwei
    APPLIED PHYSICS LETTERS, 2008, 92 (12)
  • [22] Heterodyne coherent anti-Stokes Raman scattering (CARS) imaging
    Potma, EO
    Evans, CL
    Xie, XS
    OPTICS LETTERS, 2006, 31 (02) : 241 - 243
  • [23] Difference between stokes and anti-stokes Raman shifts and time-reversal symmetry
    Li, ZY
    Chen, DM
    He, TJ
    Liu, FC
    CHINESE JOURNAL OF CHEMICAL PHYSICS, 2005, 18 (05) : 695 - 701
  • [24] INVESTIGATIONS OF THE STOKES AND ANTI-STOKES RESONANCE RAMAN-SCATTERING OF CYTOCHROME-C
    SCHOMACKER, KT
    BANGCHAROENPAURPONG, O
    CHAMPION, PM
    JOURNAL OF CHEMICAL PHYSICS, 1984, 80 (10): : 4701 - 4717
  • [25] Vibrational relaxation in β-carotene probed by picosecond Stokes and anti-Stokes resonance Raman spectroscopy
    McCamant, DW
    Kim, JE
    Mathies, RA
    JOURNAL OF PHYSICAL CHEMISTRY A, 2002, 106 (25): : 6030 - 6038
  • [26] RESONANCE COHERENT ANTI-STOKES RAMAN-SPECTROSCOPY
    LAU, A
    WERNCKE, W
    KLEIN, J
    PFEIFFER, M
    OPTICS COMMUNICATIONS, 1977, 21 (03) : 399 - 402
  • [27] COHERENT ANTI-STOKES RESONANCE RAMAN-SCATTERING
    HERRMANN, J
    LANDMANN, M
    OPTICAL AND QUANTUM ELECTRONICS, 1979, 11 (02) : 161 - 172
  • [28] COHERENT ANTI- STOKES RESONANCE RAMAN SPECTROSCOPY.
    Nitsch, W.
    Kiefer, W.
    Soviet Journal of Quantum Electronics (English translation of Kvantovaya Elektronika), 1977, 7 (12): : 1460 - 1462
  • [29] COHERENT ANTI-STOKES RESONANCE RAMAN-SPECTROSCOPY
    NITSCH, W
    KIEFER, W
    KVANTOVAYA ELEKTRONIKA, 1977, 4 (12): : 2555 - 2559
  • [30] INVERSE DETECTION OF RAMAN MAGNETIC-RESONANCE
    YANG, DW
    YE, CH
    JOURNAL OF MAGNETIC RESONANCE, 1992, 97 (02) : 271 - 281