Kinetics of emitted mass-A study with three dry powder inhaler devices

被引:24
|
作者
Behara, Srinivas Ravindra Babu [1 ]
Kippax, Paul [2 ]
Larson, Ian [1 ]
Morton, David A. V. [1 ]
Stewart, Peter [1 ]
机构
[1] Monash Univ, Monash Inst Pharmaceut Sci, Parkville, Vic 3052, Australia
[2] Malvern Instruments, Malvern WR14 1XZ, Worcs, England
关键词
Aerosol concentration; Dry powder inhaler device; Emitted mass; Kinetics; Laser diffraction; Non-linear regression modelling; IN-VITRO; RESISTANCE; PERFORMANCE; CAPSULE; DRUG; FLOW;
D O I
10.1016/j.ces.2011.07.029
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The purpose of this study was to understand the kinetics of emptying of micronised salbutamol sulphate (SS) and lactohale 300 (LH300) under varying air flow rates (30-180 L mm(-1)) from three dry powder inhaler devices, Rotahaler (R) (RH), Monodose Inhaler (R) (MI) and Handihaler (R) (HH). Aerosol concentration vs. time profiles, determined through real-time laser diffraction particle sizing, demonstrated that the majority of the powder from RH was emitted within one second while a more prolonged aerosolisation was observed from MI and HH. Peak aerosol concentrations were achieved more rapidly from RH compared to MI for both SS and LH300. Calculated cumulative emitted mass (CCEM) vs. time profiles were obtained from the aerosol concentration vs. time profiles and the emitted mass and the rate of CCEM (k(CCEM)), estimated from a modelling approach, increased with increasing air flow rates. The k(CCEM) vs. air flow rate profiles of SS and LH300 were significantly different at high air flow rates. The k(CCEM) was highest from RH and lowest from MI. Differences in k(CCEM) between the devices were related to capsule aperture size while the differences between the materials were due to the powder bed structure. This approach provided an understanding of the rate at which powder mass emptied from dry powder inhaler devices and was proposed to be a powerful development tool for the future powder inhalers. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5284 / 5292
页数:9
相关论文
共 50 条
  • [31] A preliminary study of a β-cyclodextrin/salbutamol complex for possible use in a dry powder inhaler
    Reis, AM
    Marques, HMC
    Kellaway, IW
    PROCEEDINGS OF THE 9TH INTERNATIONAL SYMPOSIUM ON CYCLODEXTRINS, 1999, : 203 - 206
  • [32] Measurement of electrostatic charge decay in pharmaceutical powders and polymer materials used in dry powder inhaler devices
    Carter, PA
    Rowley, G
    Fletcher, EJ
    Stylianopoulos, V
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1998, 24 (11) : 1083 - 1088
  • [33] A Comparison of Aerosol Performance Using Standardized Entrainment Tubes vs. Dry Powder Inhaler Devices
    Xu, Zhen
    Hickey, Anthony J.
    KONA POWDER AND PARTICLE JOURNAL, 2013, (30) : 201 - 210
  • [34] Pilot study of bronchodilator response to inhaled albuterol delivered by metered-dose inhaler and a novel dry powder inhaler
    Kemp, JP
    Hill, MR
    Vaughan, LM
    Meltzer, EO
    Welch, MJ
    Ostrom, NK
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 1997, 79 (04) : 322 - 326
  • [35] A Preference Study of Two Placebo Dry Powder Inhalers in Adults with COPD: ELLIPTA® Dry Powder Inhaler (DPI) versus DISKUS® DPI
    Kirby, Suyong Yun
    Zhu, Chang-Qing
    Kerwin, Edward M.
    Stanford, Richard H.
    Georges, George
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 13 (02) : 167 - 175
  • [36] Efficacy of a newly developed cartoon video on dry powder inhaler technique: a multicenter study
    Sirimontakan, Thitima
    Manuyakorn, Wiparat
    Kamalaporn, Harutai
    Wattanarungsun, Pornchai
    Chonpaisan, Kuntalee
    Thongkum, Korakot
    Singvijarn, Prapasiri
    Phumethum, Sintra
    ASIAN PACIFIC JOURNAL OF ALLERGY AND IMMUNOLOGY, 2022, 40 (03): : 217 - 222
  • [37] Dry powder inhaler formulation comparison: Study of the role of particle deposition pattern and dissolution
    Noriega-Fernandes, Beatriz
    Malmlof, Maria
    Nowenwik, Mattias
    Gerde, Per
    Corvo, M. Luisa
    Costa, Eunice
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2021, 607
  • [38] Satisfaction, preference and error occurrence of three dry powder inhalers as assessed by a cohort naive to inhaler operation
    Man, Kwun Nok Mimi
    Tian, Zhipeng
    Lam, David Chi-Leung
    Wan, Jennifer Man Fan
    Tan-Un, Kian Cheng
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 : 1949 - 1963
  • [39] A Study to Evaluate Patient Acceptance of Dry Powder Inhaler versus Pressurized Metered Dose Inhaler in Inhaler Naive Asthma Patients of Lower Educational Qualification
    Behera, R. K.
    Behera, D.
    INDIAN JOURNAL OF PHARMACOLOGY, 2013, 45 : S271 - S272
  • [40] Dose-ranging study of a new steroid for asthma: mometasone furoate dry powder inhaler
    Bernstein, DI
    Berkowitz, RB
    Chervinsky, P
    Dvorin, DJ
    Finn, A
    Gross, GN
    Karetzky, M
    Kemp, JP
    Laforce, C
    Lumry, W
    Mendelson, LM
    Nelson, H
    Pearlman, D
    Rachelefsky, G
    Ratner, P
    Repsher, L
    Segal, AT
    Selner, JC
    Settipane, GA
    Wanderer, A
    Cuss, FM
    Nolop, KB
    Harrison, JE
    RESPIRATORY MEDICINE, 1999, 93 (09) : 603 - 612