Brain temperature measurement: A study of in vitro accuracy and stability of smart catheter temperature sensors

被引:15
|
作者
Li, Chunyan [1 ]
Wu, Pei-Ming [1 ]
Wu, Zhizhen [2 ]
Ahn, Chong H. [2 ]
LeDoux, David [3 ]
Shutter, Lori A. [4 ]
Hartings, Jed A. [4 ]
Narayan, Raj K. [1 ,5 ]
机构
[1] N Shore Long Isl Jewish Hlth Syst, Cushing Neuromonitoring Lab, Feinstein Inst Med Res, Manhasset, NY 11030 USA
[2] Univ Cincinnati, Microsyst & BioMEMS Lab, Dept Elect & Comp Engn, Cincinnati, OH 45221 USA
[3] N Shore Univ Hosp, Neurosurg Intens Care Unit, Manhasset, NY 11030 USA
[4] Univ Cincinnati, Coll Med, Dept Neurosurg, Inst Neurosci, Cincinnati, OH 45219 USA
[5] N Shore Univ Hosp, Dept Neurosurg, Harvey Cushing Inst Neurosci, Manhasset, NY 11030 USA
关键词
Temperature microsensor; Smart catheter; Accuracy; Drift; Hypothermia; Traumatic brain injury; HEAD-INJURED PATIENTS; HYPOTHERMIA; MANAGEMENT; TUBE;
D O I
10.1007/s10544-011-9589-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The injured brain is vulnerable to increases in temperature after severe head injury. Therefore, accurate and reliable measurement of brain temperature is important to optimize patient outcome. In this work, we have fabricated, optimized and characterized temperature sensors for use with a micromachined smart catheter for multimodal intracranial monitoring. Developed temperature sensors have resistance of 100.79 +/- 1.19 Omega and sensitivity of 67.95 mV/A degrees C in the operating range from15-50A degrees C, and time constant of 180 ms. Under the optimized excitation current of 500 mu A, adequate signal-to-noise ratio was achieved without causing self-heating, and changes in immersion depth did not introduce clinically significant errors of measurements (< 0.01A degrees C). We evaluated the accuracy and long-term drift (5 days) of twenty temperature sensors in comparison to two types of commercial temperature probes (USB Reference Thermometer, NIST-traceable bulk probe with 0.05A degrees C accuracy; and IT-21, type T type clinical microprobe with guaranteed 0.1A degrees C accuracy) under controlled laboratory conditions. These in vitro experimental data showed that the temperature measurement performance of our sensors was accurate and reliable over the course of 5 days. The smart catheter temperature sensors provided accuracy and long-term stability comparable to those of commercial tissue-implantable microprobes, and therefore provide a means for temperature measurement in a microfabricated, multimodal cerebral monitoring device.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 50 条
  • [21] Overview of Temperature Sensors for Temperature Measurement of PV Modules
    Jovanovic, Ugljesa
    Jovanovic, Igor
    Mancic, Dragan
    2018 26TH TELECOMMUNICATIONS FORUM (TELFOR), 2018, : 555 - 562
  • [22] Smart composite using fibre optic sensors for fluid flow characterization and temperature measurement
    Savastru, D.
    Baschir, L.
    Miclos, S.
    Savastru, R.
    Lancranjan, I. I.
    COMPOSITE STRUCTURES, 2023, 304
  • [23] Designing Smart Temperature Sensors in Standard CMOS
    Makinwa, Kofi A. A.
    IEEE INTERNATIONAL ELECTRON DEVICES MEETING 2008, TECHNICAL DIGEST, 2008, : 425 - 425
  • [24] Temperature Sensors Modeling for Smart Power ICs
    Petrosyants, K. O.
    Rjabov, N. I.
    2011 27TH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM (SEMI-THERM), 2011, : 161 - 165
  • [25] The measure of humidity and temperature using smart sensors
    Balan, Radu
    Maties, Vistrian
    Hancu, Olimpiu
    Stan, Sergiu
    ACTUAL TASKS ON AGRICULTURAL ENGINEERING, PROCEEDINGS, 2006, 34 : 329 - +
  • [26] About accuracy of the simultaneous measurement of temperature difference and average using transducers with Pt sensors
    Warsza, Zygmunt
    Idzkowski, Adam
    PRZEMYSL CHEMICZNY, 2017, 96 (02): : 380 - 385
  • [27] Making sense of smart infrared temperature sensors
    Cook, R
    INTECH, 1997, 44 (05) : 52 - 55
  • [28] CMOS-compatible smart temperature sensors
    Bianchi, RA
    Dos Santos, FV
    Karam, JM
    Courtois, B
    Pressecq, F
    Sifflet, S
    MICROELECTRONICS JOURNAL, 1998, 29 (09) : 627 - 636
  • [29] IMPROVING THE ACCURACY OF THE TEMPERATURE-MEASUREMENT OF GASES BY CORRECTION FOR THE RESPONSE DELAYS IN THE THERMAL SENSORS
    DOWNS, MJ
    FERRISS, DH
    WARD, RE
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1990, 1 (08) : 717 - 719
  • [30] CMOS Smart Temperature Sensors for RFID Applications
    Martinez Brito, Juan Pablo
    Rabaeijs, Alain
    2013 26TH SYMPOSIUM ON INTEGRATED CIRCUITS AND SYSTEMS DESIGN (SBCCI 2013), 2013,