摘要
Bonner sphere spectrometers (BSS) are being used widely in neutron spectrometry since 1960. The response to neutrons of these moderating detectors spans over a broad energy range. This work discusses the measurement of the sensitivity of an extended range BSS hosting a CR39 nuclear track detector coupled to a boron converter. Two kinds of boron converters were tested, the first made by natural boron and a second one enriched in B-10. The BSS response functions were calculated with Monte Carlo simulation using the MCNPX 2.4.0. and the FLUKA codes.
引用
收藏
页码:310 / 313
页数:4
相关论文
共 50 条
  • [21] Development of an extended-range Bonner sphere spectrometer for China initiative accelerator-driven system
    Wen, Z. W.
    Song, S. Y.
    Xu, J. K.
    Gong, Y. W.
    Huang, Y. X.
    Ran, J. L.
    Tang, X. Q.
    Chen, Z. Q.
    Li, Y.
    Luo, P.
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (02) : 152 - 163
  • [22] Performance evaluation of a radiator degrader CR39 based neutron spectrometer
    Caresana, M.
    Ferrarini, M.
    Porta, A.
    Campi, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 680 : 155 - 160
  • [23] New results from exposures of CR39 nuclear track detectors
    Giacomelli, G
    Patrizii, L
    Popa, V
    Serra, P
    Togo, V
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 217 - 222
  • [24] SENSITIVITY OF RADON MEASUREMENTS WITH CR-39 TRACK ETCH DETECTOR - A MONTE-CARLO STUDY
    NIKEZIC, D
    KOSTIC, D
    KRSTIC, D
    SAVOVIC, S
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 647 - 648
  • [26] Calibrations of CR39 and Makrofol nuclear track detectors and search for exotic particles
    Togo, V
    Ambrosio, M
    Antolini, R
    Auriemma, G
    Bakari, D
    Baldini, A
    Barbarino, GC
    Barish, BC
    Battistoni, G
    Becherini, Y
    Bellotti, R
    Bemporad, C
    Bernardini, P
    Bilokon, H
    Bloise, C
    Bower, C
    Brigida, M
    Bussino, S
    Cafagna, F
    Campana, D
    Carboni, M
    Caruso, R
    Cecchini, S
    Cei, F
    Chiarella, V
    Chiarusi, T
    Choudhary, BC
    Coutu, S
    Cozzi, M
    De Cataldo, G
    Dekhissi, H
    De Marzo, C
    Erriquez, O
    Favuzzi, C
    Forti, C
    Fusco, P
    Giacomelli, G
    Giannini, G
    Giglietto, N
    Giorgini, M
    Grassi, M
    Grillo, A
    Guarino, F
    Gustavino, C
    Habig, A
    Hanson, K
    Heinz, R
    Iarocci, E
    Katsavounidis, E
    Katsavounidis, I
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 217 - 221
  • [27] SENSITIVITY STUDY OF CR-39 PLASTIC TRACK DETECTORS
    HE, YD
    PRICE, PB
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (03): : 491 - 494
  • [28] Sensitivity study of CR-39 plastic track detectors
    He, Y.D.
    Price, P.B.
    Nuclear Tracks and Radiation Measurements, 1992, 20 (03): : 491 - 494
  • [29] A WIDE-RANGE NEUTRON DOSIMETER BASED ON A CR-39 TRACK DETECTOR
    LUSZIKBHADRA, M
    ALBERTS, WG
    DIETZ, E
    GULDBAKKE, S
    MATZKE, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 671 - 674
  • [30] A simple apparatus for quick qualitative analysis of CR39 nuclear track detectors
    Gautier, D. C.
    Kline, J. L.
    Flippo, K. A.
    Gaillard, S. A.
    Letzring, S. A.
    Hegelich, B. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):