Intraocular Pressure Changes during Hemodiafiltration with Two different Concentrations of Sodium in the Dialysate

被引:1
|
作者
Lerma, Claudiap [1 ]
Saavedra-Fuentes, Nadia [2 ]
Ledesma-Gil, Jasbeth [3 ]
Calderon-Juarez, Martin [1 ,4 ]
Perez-Grovas, Hector
Lopez-Gil, Salvador [2 ]
机构
[1] Inst Nacl Cardiol Ignacio Chavez, Dept Instrumentac Electromecan, Mexico City 14080, DF, Mexico
[2] Inst Nacl Cardiol Ignacio Chavez, Dept Nefrol, Mexico City 14080, DF, Mexico
[3] Inst Oftalmol Conde Valenciana, Dept Glaucoma, Mexico City 06800, DF, Mexico
[4] Univ Nacl Autonoma Mexico, Fac Med, Plan Estudios Combinados Med, Mexico City 04510, DF, Mexico
来源
BIOLOGY-BASEL | 2022年 / 11卷 / 01期
关键词
intraocular pressure; hemodiafiltration; sodium concentration; intra-dialytic changes; AQUEOUS-HUMOR DYNAMICS; KIDNEY-DISEASE; HEMODIALYSIS; GLAUCOMA; PREVENTION; PATIENT; PATHOPHYSIOLOGY; ELEVATION; RISE;
D O I
10.3390/biology11010012
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Simple Summary An increase in intraocular pressure during chronic hemodialysis is linked to ocular complications, such as glaucoma. The behavior of intraocular pressure during hemodiafiltration is unknown. Changes in intraocular pressure with a sodium dialysate concentration fixed at 138 mmol/L and an individualized concentration were studied in 13 patients with end-stage renal disease treated with hemodiafiltration. Up to 31% patients presented an episode of intraocular hypertension without differences between sodium profiles. A large variability in intraocular pressure within patients and a high prevalence of transient intraocular hypertension were found. Ocular complications are common among end-stage renal disease patients and some complications had been linked to increments of intraocular pressure (IOP) during hemodialysis. The changes of IOP during hemodiafiltration (HDF) have been scarcely investigated and the potential influence of the sodium dialysate concentration is unknown. The aim of this study was to compare the IOP changes during HDF with sodium dialysate concentration, either fixed or individualized. Thirteen end-stage renal disease patients participated in the study; they were treated with HDF using a dialysate sodium profile fixed at 138 mmol and another session with an individualized sodium profile. The intraocular pressure was measured before and after each session and every 30 min during HDF. Both groups had a similar HDF prescription, blood pressure, and biochemical parameters. At the end of hemodiafiltration, sodium concentration decreased only in the fixed sodium profile group. The number of patients with at least an episode of intraocular hypertension during HDF ranged from 5 (19%) to 8 (31%) without significant differences between right and left eye nor between dialysate sodium concentration. During HDF, there is a large variability of IOP; transient events of intraocular hypertension are highly prevalent in this sample, and they are not related to the sodium dialysate concentration.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] CHANGES IN INTRAOCULAR-PRESSURE DURING ACUTE EXERCISE
    KREJCI, RC
    GORDON, RB
    MORAN, CT
    SARGENT, RG
    MAGUN, JC
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1981, 58 (02): : 144 - 148
  • [32] The course of corneal and intraocular pressure changes during pregnancy
    Efe, Yasemin Kozluca
    Ugurbas, Silay Canturk
    Alpay, Atilla
    Ugurbas, Suat Hayri
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2012, 47 (02): : 150 - 154
  • [33] CHANGES IN INTRAOCULAR PRESSURE OF THE OTHER EYE DURING TONOGRAPHY
    STOCKER, FW
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1958, 45 (01) : 127 - 127
  • [34] EFFECT OF DIFFERENT DIALYSATE SODIUM CONCENTRATION ON BLOOD PRESSURE IN HEMODIALYSIS PATIENTS: A RANDOMIZED STUDY
    Ekart, R.
    Volgemut, Z.
    Bevc, S.
    Stropnik-Galuf, T.
    Hojs, R.
    JOURNAL OF HYPERTENSION, 2015, 33 : E224 - E225
  • [35] Thermal effects and blood pressure response during postdilution hemodiafiltration and hemodialysis: The effect of amount of replacement fluid and dialysate temperature
    Van Der Sande, FM
    Kooman, JP
    Konings, CJ
    Leunissen, KML
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2001, 12 (09): : 1916 - 1920
  • [36] POSTOPERATIVE INTRAOCULAR-PRESSURE CHANGES WITH USE OF DIFFERENT VISCOELASTICS
    DADA, VK
    SINDHU, N
    SACHDEV, MS
    OPHTHALMIC SURGERY AND LASERS, 1994, 25 (08): : 540 - 544
  • [37] ACUTE EFFECTS OF DIFFERENT CONCENTRATIONS OF DIALYSATE MAGNESIUM DURING HIGH-EFFICIENCY DIALYSIS
    JACOBO, K
    SLATOPOLSKY, E
    DELMEZ, JA
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 24 (03) : 453 - 460
  • [38] BLOOD-PRESSURE CONTROL DURING MAINTENANCE HEMODIALYSIS WITH ISONATRIC (HIGH SODIUM) DIALYSATE
    STEWART, WK
    FLEMING, LW
    POSTGRADUATE MEDICAL JOURNAL, 1974, 50 (583) : 260 - 264
  • [39] Changes in Intraocular indocyanine green concentrations during macular hole surgery
    Ohguro, Hiroshi
    Ohguro, Ikuyo
    Ishikawa, Futoshi
    Hitoshi, Yamazaki
    Yokoi, Yumiko
    Nakazawa, Mitsuru
    OPHTHALMOLOGICA, 2007, 221 (06) : 402 - 405
  • [40] CHANGES IN INTRAOCULAR-PRESSURE DURING SIMULATED MOSLEM PRAYERS
    ALMANSOURI, S
    ALKASSIMI, H
    SHIHAB, Z
    TOMEY, K
    SAUDI MEDICAL JOURNAL, 1994, 15 (04) : 286 - 289