Intraocular Pressure Changes during Hemodiafiltration with Two different Concentrations of Sodium in the Dialysate

被引:1
|
作者
Lerma, Claudiap [1 ]
Saavedra-Fuentes, Nadia [2 ]
Ledesma-Gil, Jasbeth [3 ]
Calderon-Juarez, Martin [1 ,4 ]
Perez-Grovas, Hector
Lopez-Gil, Salvador [2 ]
机构
[1] Inst Nacl Cardiol Ignacio Chavez, Dept Instrumentac Electromecan, Mexico City 14080, DF, Mexico
[2] Inst Nacl Cardiol Ignacio Chavez, Dept Nefrol, Mexico City 14080, DF, Mexico
[3] Inst Oftalmol Conde Valenciana, Dept Glaucoma, Mexico City 06800, DF, Mexico
[4] Univ Nacl Autonoma Mexico, Fac Med, Plan Estudios Combinados Med, Mexico City 04510, DF, Mexico
来源
BIOLOGY-BASEL | 2022年 / 11卷 / 01期
关键词
intraocular pressure; hemodiafiltration; sodium concentration; intra-dialytic changes; AQUEOUS-HUMOR DYNAMICS; KIDNEY-DISEASE; HEMODIALYSIS; GLAUCOMA; PREVENTION; PATIENT; PATHOPHYSIOLOGY; ELEVATION; RISE;
D O I
10.3390/biology11010012
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Simple Summary An increase in intraocular pressure during chronic hemodialysis is linked to ocular complications, such as glaucoma. The behavior of intraocular pressure during hemodiafiltration is unknown. Changes in intraocular pressure with a sodium dialysate concentration fixed at 138 mmol/L and an individualized concentration were studied in 13 patients with end-stage renal disease treated with hemodiafiltration. Up to 31% patients presented an episode of intraocular hypertension without differences between sodium profiles. A large variability in intraocular pressure within patients and a high prevalence of transient intraocular hypertension were found. Ocular complications are common among end-stage renal disease patients and some complications had been linked to increments of intraocular pressure (IOP) during hemodialysis. The changes of IOP during hemodiafiltration (HDF) have been scarcely investigated and the potential influence of the sodium dialysate concentration is unknown. The aim of this study was to compare the IOP changes during HDF with sodium dialysate concentration, either fixed or individualized. Thirteen end-stage renal disease patients participated in the study; they were treated with HDF using a dialysate sodium profile fixed at 138 mmol and another session with an individualized sodium profile. The intraocular pressure was measured before and after each session and every 30 min during HDF. Both groups had a similar HDF prescription, blood pressure, and biochemical parameters. At the end of hemodiafiltration, sodium concentration decreased only in the fixed sodium profile group. The number of patients with at least an episode of intraocular hypertension during HDF ranged from 5 (19%) to 8 (31%) without significant differences between right and left eye nor between dialysate sodium concentration. During HDF, there is a large variability of IOP; transient events of intraocular hypertension are highly prevalent in this sample, and they are not related to the sodium dialysate concentration.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Intraocular Pressure Changes During Hemodialysis or Hemodiafiltration in End-Stage Renal Disease Patients
    Saavedra-Fuentes, Nadia
    Perez-Grovas, Hector
    Navarrete, Ruth
    Lerma, Claudia
    THERAPEUTIC APHERESIS AND DIALYSIS, 2018, 22 (06) : 624 - 629
  • [2] The effect of different dialysate sodium concentrations on ambulatory blood pressure in hemodialysis patients: a prospective interventional study
    Bratsiakou, Adamantia
    Iatridi, Fotini
    Theodorakopoulou, Marieta
    Sarafidis, Pantelis
    Goumenos, Dimitrios S.
    Papachristou, Evangelos
    Papasotiriou, Marios
    CLINICAL KIDNEY JOURNAL, 2024, 17 (08)
  • [3] Intraocular pressure during lamellar cuts with two different microkeratomes
    Sachs, HG
    Lohmann, CP
    de Laak, JPO
    OPHTHALMOLOGE, 1997, 94 (10): : 707 - 709
  • [4] Intraocular pressure during lamellar cuts with two different microkeratomes
    Helmut G. Sachs
    Chris P. Lohmann
    Jean P. Op de Laak
    Der Ophthalmologe, 1997, 94 : 707 - 709
  • [5] THE EFFECT OF DIFFERENT DIALYSATE SODIUM CONCENTRATIONS ON AMBULATORY BLOOD PRESSURE AND PULSE WAVE VELOCITY ON HEMODIALYSIS PATIENTS
    Bratsiakou, Adamantia
    Papasotiriou, Marios
    Alexandrou, Maria Eleni
    Mpimpis, Theodoros
    Georgopoulou, Georgia Andriana
    Tsiotsios, Konstantinos
    Goumenos, Dimitrios
    Sarafidis, Pantelis
    Papachristou, Evangelos
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2023, 38 : I997 - I998
  • [6] Changes in Intraocular Pressure During Pregnancy
    Artunay, Ozgur
    Sengul, Alper
    Yuzbasioglu, Erdal
    Rasier, Rifat
    Bahcecioglu, Halil
    Guducu, Nilgun
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2010, 40 (02): : 80 - 83
  • [7] INTRAOCULAR PRESSURE CHANGES DURING HEMODIALYSIS
    RAMSELL, JT
    ELLIS, PP
    PATERSON, CA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1971, 72 (05) : 926 - &
  • [8] CHANGES IN INTRAOCULAR PRESSURE DURING HEMODIALYSIS
    SITPRIJA, V
    HOLMES, JH
    ELLIS, PP
    INVESTIGATIVE OPHTHALMOLOGY, 1964, 3 (03): : 273 - 284
  • [9] SEQUENTIAL-CHANGES IN DIALYSATE SODIUM (DNA) DURING HEMODIALYSIS
    RAJA, R
    KRAMER, M
    BARBER, K
    CHEN, S
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1983, 29 : 649 - 651
  • [10] CHANGES OF INTRAOCULAR PRESSURE AND OF CHLORIDE SODIUM AND POTASSIUM CONCENTRATIONS IN AQUEOUS HUMOR AND SERUM OF RABBITS FOLLOWING CHLORPROMAZINE
    RAMOS, L
    GIESBRECHT, AM
    CALDEIRA, JA
    RAMOS, AO
    OPHTHALMOLOGICA, 1969, 157 (04) : 279 - +