Comprehensive study and optimization of concentrated photovoltaic-thermoelectric considering all contact resistances

被引:92
|
作者
Shittu, Samson [1 ]
Li, Guiqiang [1 ,2 ]
Zhao, Xudong [1 ,2 ]
Ma, Xiaoli [1 ]
Akhlaghi, Yousef Golizadeh [1 ]
Fan, Yi [1 ]
机构
[1] Univ Hull, Res Ctr Sustainable Energy Technol, Kingston Upon Hull HU6 7RX, N Humberside, England
[2] North China Elect Power Univ, Dept Power Engn, Beijing, Peoples R China
基金
英国工程与自然科学研究理事会; “创新英国”项目;
关键词
Photovoltaic-thermoelectric; Contact resistance; Thermal contact; Electrical contact; Finite element method; MICROCHANNEL HEAT-PIPE; PERFORMANCE ANALYSIS; TEMPERATURE DISTRIBUTION; NUMERICAL-ANALYSIS; COOLING SYSTEM; HYBRID SYSTEM; SOLAR-CELL; GENERATOR; DESIGN; GEOMETRY;
D O I
10.1016/j.enconman.2019.112422
中图分类号
O414.1 [热力学];
学科分类号
摘要
A consequence of the integration of photovoltaic module and thermoelectric generator is the presence of thermal contact, which affects the heat transfer in the hybrid system. Thermal and electrical contact are inevitable in a thermoelectric generator and their effects on the performance of the thermoelectric generator can be significant if not properly managed. Therefore, this study presents a comprehensive three-dimensional numerical investigation on the effect of contact resistances on the performance of concentrated photovoltaic-thermoelectric using COMSOL 5.4 Multiphysics software. Four contact resistances are studied including thermoelectric thermal contact resistance, thermoelectric electrical contact resistance, photovoltaic-thermoelectric interface thermal contact resistance and thermoelectric generator-heat sink interface thermal contact resistance. Twelve contact resistance cases are considered, and a comparison study is presented to investigate the most important contact resistance. In addition, a parametric optimization study is performed to investigate the optimum values for thermoelectric leg height, load resistance, concentration ratio and convective heat transfer coefficient. Results show that ignoring all contact resistances in the hybrid system causes an overestimation of overall power output and efficiency by 7.6% and 7.4% respectively using the base values considered in this study. In addition, the thermal contact resistance between the thermoelectric generator and heat sink, and that between the photovoltaic-thermoelectric interface are found to be the most important contact resistances, which should be reduced. Furthermore, results show that the optimum thermoelectric external load resistance in a hybrid system is lower than that of the thermoelectric generator only system. This study will provide valuable guidance on photovoltaic-thermoelectric accurate modelling.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Thermal-Electrical Model of Concentrated Photovoltaic-Thermoelectric Generator Combined System for Energy Generation
    Alnahhal, Ahmed Issa
    Halal, Ahmad
    Plesz, Balazs
    2022 28TH INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATIONS OF ICS AND SYSTEMS (THERMINIC 2022), 2022,
  • [42] All-day continuous power generation: Integrating radiative cooling with semi-transparent photovoltaic cells filtered concentrated photovoltaic-thermoelectric generator system
    Lai, Peigen
    Han, Xinyue
    Chen, Xu
    Huang, Ju
    SOLAR ENERGY, 2025, 287
  • [43] Numerical analysis and optimization of a spectrum splitting concentration photovoltaic-thermoelectric hybrid system
    Ju, Xing
    Wang, Zhifeng
    Flamant, Gilles
    Li, Peng
    Zhao, Wenyu
    SOLAR ENERGY, 2012, 86 (06) : 1941 - 1954
  • [44] Smart Optimization of Semiconductors in Photovoltaic-Thermoelectric Systems Using Recurrent Neural Networks
    Alghamdi, Hisham
    Maduabuchi, Chika
    Okoli, Kingsley
    Albaker, Abdullah
    Alatawi, Ibrahim
    Alsafran, Ahmed S. S.
    Alkhedher, Mohammad
    Chen, Wei-Hsin
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2023, 2023
  • [45] Experimental performance study of a solar parabolic dish photovoltaic-thermoelectric generator
    Bamroongkhan, P.
    Lertsatitthanakorn, C.
    Soponronnarit, S.
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 528 - 533
  • [46] Optimization of Photovoltaic-Thermoelectric Hybrid System via Multi-Objective Genetic Algorithm
    Yin, Ershuai
    Li, Qiang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (06): : 1669 - 1674
  • [47] Multi-objective optimization of concentrated Photovoltaic-Thermoelectric hybrid system via non-dominated sorting genetic algorithm (NSGA II)
    Yusuf, Aminu
    Bayhan, Nevra
    Tiryaki, Hasan
    Hamawandi, Bejan
    Toprak, Muhammet S.
    Ballikaya, Sedat
    ENERGY CONVERSION AND MANAGEMENT, 2021, 236
  • [48] Optimization of the performance and operation of a photovoltaic-thermoelectric power supply system for bridge safety monitoring microsystems
    Wei, Guorui
    Lin, Tao
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 57
  • [49] Research and numerical analysis on performance optimization of photovoltaic-thermoelectric system incorporated with phase change materials
    Lv, Song
    Yang, Jiahao
    Ren, Juwen
    Zhang, Bolong
    Lai, Yin
    Chang, Zhihao
    ENERGY, 2023, 263
  • [50] Bending strength evaluation and power generation performance optimization of a curved photovoltaic-thermoelectric hybrid device
    Liu, C.
    Cui, Y. J.
    Wang, K. F.
    Wang, B. L.
    COMPOSITE STRUCTURES, 2023, 321