The fetal portal vein: normal blood flow development during the second half of human pregnancy

被引:37
|
作者
Kessler, J. [1 ]
Rasmussen, S.
Kiserud, T.
机构
[1] Haukeland Hosp, Dept Obstet & Gynecol, N-5021 Bergen, Norway
[2] Univ Bergen, Dept Clin Med, Bergen, Norway
[3] Univ Bergen, Norwegian Inst Publ Hlth, Locus Reg Based Epidemiol, Med Birth Reg Norway, Bergen, Norway
关键词
blood flow; circulation; Doppler ultrasound; fetus; portal vein;
D O I
10.1002/uog.4054
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives The umbilical vein is the major source of blood for the fetal liver, but portal blood, which has not been measured directly in human fetuses, probably constitutes a physiologically important contribution. We aimed to establish a method for measuring blood flow in the fetal portal vein and to produce longitudinal reference ranges for diameter, blood flow velocities and volume blood flow during the second half of pregnancy. Methods After a pilot project to develop the measuring technique, 160 low-risk pregnant women were recruited to a longitudinal study that included ultrasound examinations at 4-5-week intervals starting at 20-22 weeks of gestation. The inner diameter (D) of the vessel was measured with a perpendicular insonation angle, and the time-averaged maximum blood velocity (TAMXV) and weighted mean velocity (VWMEAN) were recorded with an insonation directed along the long axis of the vessel. Portal flow was calculated as: Q = pi(D/2)(2) x h x TAMXV (where h is a velocity profile parameter and equals 0.5). Portal flow was normalized for estimated fetal weight based on birth-weight percentiles. Results The portal vein could be visualized and measured in 558/593 (94%) cases. Blood flow was pulsatile. D and TAMXV doubled during the second half of pregnancy (21-39 weeks), from 1.5 to 3.4 mm and from 8.4 to 14.9 cm/s, respectively. Correspondingly, the portal flow increased from 5 to 41 mL/min, and from 10 to 13 mL/min/kg when normalized for fetal weight. Similar results were achieved for VWMEAN. Conclusion Portal flow can be measured with a standardized technique. It increases during the second half of pregnancy, even when normalized for fetal weight, suggesting that it has increasing importance in the fetal liver circulation. Copyright (C) 2007 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:52 / 60
页数:9
相关论文
共 50 条
  • [31] Uterine and Fetal Blood Flow Indices and Fetal Growth Assessment after Chronic Estrogen Suppression in the Second Half of Baboon Pregnancy.
    Aberdeen, Graham W.
    Baschat, Ahmet A.
    Harman, Chris R.
    Weiner, Carl P.
    Langenberg, Patricia W.
    Pepe, Gerald J.
    Albrecht, Eugene D.
    REPRODUCTIVE SCIENCES, 2010, 17 (03) : 357A - 357A
  • [32] Analysis of biochemical parameters in canine fetal fluids during the second half of pregnancy
    Tal, S.
    Sutton, G. A.
    Arlt, S. P.
    Bar-Gal, G. Kahila
    THERIOGENOLOGY, 2022, 189 : 31 - 41
  • [33] Fetal branch pulmonary arterial vascular impedance during the second half of pregnancy
    Rasanen, J
    Huhta, JC
    Weiner, S
    Wood, DC
    Ludomirski, A
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 174 (05) : 1441 - 1449
  • [34] Maternal salivary cortisol differs by fetal sex during the second half of pregnancy
    DiPietro, Janet A.
    Costigan, Kathleen A.
    Kivlighan, Katie T.
    Chen, Ping
    Laudenslager, Mark L.
    PSYCHONEUROENDOCRINOLOGY, 2011, 36 (04) : 588 - 591
  • [35] Fetal and maternal plasma homocysteine levels during the second half of uncomplicated pregnancy
    Radunovic, Nebojsa
    Lockwood, Charles J.
    Stanojlovic, Olivera
    Steric, Milena
    Kontic-Vucinic, Olivera
    Sulovic, Nenad
    Hrncic, Dragan
    Ackerman, William E.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2015, 28 (11): : 1244 - 1249
  • [36] Acceleration time in the fetal middle cerebral artery during the second half of pregnancy
    Da Costa, AG
    Maud, F
    Spara, P
    De Freitas, P
    Arévalo, J
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (03): : 317 - 320
  • [37] HEMODYNAMIC INVESTIGATION OF FLOW IN THE NORMAL PORTAL VEIN
    George, Stephanie M.
    Martin, Diego R.
    Giddens, Don P.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 635 - 636
  • [38] Reversal of flow in a normal variant of the portal vein
    Ohnami, Y
    Ishida, H
    Uno, A
    Konno, K
    Naganuma, H
    Masamune, O
    JOURNAL OF CLINICAL ULTRASOUND, 1996, 24 (06) : 317 - 320
  • [39] Reactivity of the human fetal pulmonary circulation to maternal hyperoxygenation increases during the second half of pregnancy - A randomized study
    Rasanen, J
    Wood, DC
    Debbs, RH
    Cohen, J
    Weiner, S
    Huhta, JC
    CIRCULATION, 1998, 97 (03) : 257 - 262
  • [40] Human fetal right ventricular ejection force under abnormal loading conditions during the second half of pregnancy
    Rasanen, J
    Debbs, RH
    Wood, DC
    Weiner, S
    Weil, SR
    Huhta, JC
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 10 (05) : 325 - 332