Experimental study on the thermal performance of tunnel lining GHE under groundwater flow

被引:56
|
作者
Zhang, Guozhu [1 ]
Guo, Yimu
Zhou, You
Ye, Meixi
Chen, Runfa
Zhang, Hualin
Yang, Junda
Chen, Jiawei
Zhang, Menghuan
Lian, Yanjian
Liu, Chenyang
机构
[1] Southeast Univ, Inst Geotech Engn, Nanjing 210096, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Metro tunnel; Tunnel lining GHE; Geothermal energy; Model test; Groundwater flow; BOREHOLE HEAT-EXCHANGER; ENERGY PILE; NUMERICAL EVALUATION; RESPONSE TESTS; TEMPERATURE; BEHAVIOR; SYSTEM; MODEL; FOUNDATIONS; SIMULATION;
D O I
10.1016/j.applthermaleng.2016.06.041
中图分类号
O414.1 [热力学];
学科分类号
摘要
The metro tunnel constructed at a depth where the ground temperature is constant meets the basic requirement of a heat source for a ground source heat pump (GSHP) system, and the tunnel lining ground heat exchangers (GHE) transfer the heat through absorber pipes installed in the tunnel lining, which can be used for heating and/or cooling buildings near the tunnel. More and more metro tunnels have been constructed in sandy soil layers with higher permeability in China. In order to evaluate the effect of groundwater on the thermal performance of tunnel lining GHE, a tunnel lining GHE laboratory model test is carried out. The test results show that (i) the groundwater flow velocity that is greater than 1 x 10(-5) m/s is conducive to surrounding rock temperature recovery, the influence regions of the heat exchange on the temperature field of the surrounding rock is about 22.5 cm away from the tunnel lining when the flow rate is less than 1 x 10(-5) m/s; (ii) the groundwater flow can enhance the heat exchange rate of tunnel lining GHE, when the (low velocity changes from I x 10(-4) m/s to 5 x 10(-4) m/s, the heat exchange rate increases by 9.8%, 9.78% and 4.67% after running 8 h when the temperature difference between the inlet temperature of the heat exchange pipes.and the ground temperature are 6.7 degrees C, 11.6 degrees C and 16.7 degrees C, respectively; (iii) the heat exchange rate of the tunnel lining GHE increases linearly with the temperature difference under (he groundwater flow, the growth gradient is 5.10 W/degrees C when the groundwater flow velocity is 5 x 10(-4) m/s; (iv) when the water head and inlet temperature are the same, the cross distribution with a series circuit is good for improving the heat exchange rate. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:784 / 795
页数:12
相关论文
共 50 条
  • [31] Experimental study and engineering application of coupling performance between distributed embedded optical fiber and tunnel lining
    Hou Gong-yu
    Xie Bing-bing
    Han Yu-chen
    Hu Tao
    Li Zi-xiang
    Yang Xing-kun
    Zhou Tian-ci
    Xiao Hai-lin
    ROCK AND SOIL MECHANICS, 2020, 41 (02) : 714 - 726
  • [32] Experimental study on self-healing performance of tunnel lining concrete based on response surface methodology
    Li, Huayun
    Wu, Yangfan
    Zhou, Anxiang
    Zhao, Chenxi
    Deng, Lai
    Lu, Feng
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 425
  • [33] Experimental and numerical investigation on cracking mechanism of tunnel lining under bias pressure
    Liu, Dejun
    Li, Meng
    Zuo, Jianping
    Gao, Yang
    Zhong, Fei
    Zhang, Yang
    Chang, Yongquan
    THIN-WALLED STRUCTURES, 2021, 163
  • [34] Thermal performance assessment of an energy lining for the Lyon-Turin base tunnel
    Alvi, Maria Romana
    Insana, Alessandra
    Barla, Marco
    SOILS AND ROCKS, 2022, 45 (01):
  • [35] Performance of the Prestressed Composite Lining of a Tunnel: Case Study of the Yellow River Crossing Tunnel
    Yang, Fan
    Cao, Shengrong
    Qin, Gan
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2018, 16 (2A) : 229 - 241
  • [36] Experimental Study of the Effect of Different Well Flow Quota on Groundwater Thermal Flow Transport Variation
    Zhou, Xuezhi
    Gao, Qing
    Ma, Chunqiang
    Zhao, Xiaowen
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4239 - +
  • [37] Study of infrared thermal application for detecting defects within tunnel lining
    Afshani, Alireza
    Kawakami, Koichi
    Konishi, Shinji
    Akagi, Hirokazu
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2019, 86 : 186 - 197
  • [38] Performance of the Prestressed Composite Lining of a Tunnel: Case Study of the Yellow River Crossing Tunnel
    Fan Yang
    Shengrong Cao
    Gan Qin
    International Journal of Civil Engineering, 2018, 16 : 229 - 241
  • [39] Experimental study on influence of blasting construction on secondary lining structure of tunnel
    Chen, Qiunan
    He, Yongchao
    Zou, Gen
    Li, Junjie
    Zhou, Xiangshi
    Zhou, Guangyu
    Journal of Railway Science and Engineering, 2020, 17 (03): : 676 - 681
  • [40] Experimental study on deformational resilience of longitudinal joint in shield tunnel lining
    Zhang, Yanjie
    Saadat, Yalda
    Huang, Hongwei
    Zhang, Dongming
    Ayyub, Bilal M.
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2024, 20 (03) : 368 - 379