Fuzzy logic controller for three-level shunt active filter compensating harmonics and reactive power

被引:18
|
作者
Saidi, Salem [1 ]
Abbassi, Rabeh [1 ]
Chebbi, Souad [1 ]
机构
[1] Univ Tunis, Natl Higher Sch Engn Tunis ENSIT, Lab Technol Informat & Commun & Elect Engn LaTICE, BP 56-1008 Bab Menara, Tunis, Tunisia
关键词
Harmonics; fuzzy logic control; reactive power; instantaneous reactive power theory (P-Q theory); shunt active filter; power quality; imbricated cells inverter; space vector pulse width modulation; SOURCE INVERTER; STRATEGY; MODULATION; DESIGN;
D O I
10.1002/acs.2637
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, the use of a three-level inverter as a shunt active power filter is carried out, taking advantage of the benefits of multi-level inverter, namely, the reduction both in the overall switching losses and in total harmonic distortion. The main focus of this article is to investigate the potentialities of the inverter employed as shunt active power filter on the compensation of the reactive power and the mitigation of harmonics drawn from a nonlinear load and unbalanced sources. The most previously reported three-level inverter-based shunt active power filters have been controlled and monitored through conventional controllers, which require a complicated mathematical model. In order to overcome this problem, an extended intelligent controller is proposed for a three-level shunt active power filter. The aim of the proposed fuzzy logic control algorithm is to improve the behavior of voltage across the floating capacitors in steady/dynamic states and to minimize the switches commutations by taking into account the references of the harmonic currents injected in the network. The proposed control strategy has been simulated, and the obtained results prove that it is very successful. Copyright (C) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:809 / 823
页数:15
相关论文
共 50 条
  • [21] Advanced PLL with multivariable filter and fuzzy logic controller based shunt active Power Filter
    Benyamina, Abderrahmen
    Moulahoum, Samir
    Houassine, Hamza
    Kabache, Nadir
    2015 20TH INTERNATIONAL CONFERENCE ON METHODS AND MODELS IN AUTOMATION AND ROBOTICS (MMAR), 2015, : 364 - 369
  • [22] Fuzzy logic controller for five-level shunt active power filter under distorted voltage conditions
    Benaissa, Amar
    Rabhi, Boualaga
    Benkhoris, Mohamed Fouad
    Moussi, Ammar
    Le Claire, Jean-Claude
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 4973 - 4978
  • [23] Instantaneous active and reactive current control technique of shunt active power filter based on the three-level NPC inverter
    Pouresmaeil, Edris
    Montesinos-Miracle, Daniel
    Gomis-Bellmunt, Oriol
    Sudria-Andreu, Antoni
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2011, 21 (07): : 2007 - 2022
  • [24] Reactive power and voltage harmonics compensation of a shunt power active filter
    Menniti, D.
    Picardi, C.
    Pinnarelli, A.
    Sorrentino, N.
    2006 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3, 2006, : 1293 - +
  • [25] Three-Phase Three-Level Inverter Based Shunt Active Power Filter
    Altin, Necmi
    Kaplan, Orhan
    Ozdemir, Saban
    2014 16TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE AND EXPOSITION (PEMC), 2014, : 799 - 804
  • [26] Modeling and Resonance Control of Modular Three-Level Shunt Active Power Filter
    Feng, Ling
    Wang, Yong
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (09) : 7478 - 7486
  • [27] Analysis and implementation of shunt active power filter with three-level PWM scheme
    Lin, BR
    Huang, CH
    Yang, TY
    Lee, YC
    PEDS 2003 : FIFTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, : 1580 - 1585
  • [28] A fuzzy logic approach to shunt active power filter and hybrid active power filter
    Sahoo, Nirjharini
    Panda, Gayadhar
    Subudhi, B. D.
    JOURNAL OF POWER TECHNOLOGIES, 2023, 103 (04): : 209 - 217
  • [29] A Fast Acting 1/z Controller for Shunt Active Filter Operation for Harmonics and Reactive Power Compensation
    Patidar, R. D.
    Singh, S. P.
    IEEE REGION 10 COLLOQUIUM AND THIRD INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS, VOLS 1 AND 2, 2008, : 217 - 222
  • [30] Fuzzy logic PWM current controller based shunt active power filter for power quality compensation
    Bayindir, K. Cagatay
    Tuemay, Mehmet
    Cuma, M. Ugras
    ENGINEERING INTELLIGENT SYSTEMS FOR ELECTRICAL ENGINEERING AND COMMUNICATIONS, 2008, 16 (01): : 5 - 16