New Tungsten Cluster Based Contrast Agents for X-ray Computed Tomography

被引:17
|
作者
Suelzle, Detlev [1 ]
Bauser, Marcus [1 ]
Frenzel, Thomas [1 ]
Jost, Gregor [1 ]
Pietsch, Hubertus [1 ]
Schaefer, Martina [1 ]
Berger, Markus [1 ]
Hassfeld, Jorma [2 ]
Schmitt-Willich, Heribert [3 ]
机构
[1] Bayer Pharma AG, Global Drug Discovery, D-13342 Berlin, Germany
[2] Bayer Pharma AG, Global Chem Dev, D-42096 Wuppertal, Germany
[3] Piramal Imaging GmbH, D-13353 Berlin, Germany
关键词
Tungsten; X-ray contrast agent; Regio isomers; W3O2; complexes; Ligand design; EXCHANGE; MO;
D O I
10.1007/s10876-014-0786-1
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In recognition of the seminal contributions of F. A. Cotton and A. Bino to the field of aqueous chemistry of organometallic, trinuclear cluster compounds of tungsten, we describe their modifications and use as contrast agents for X-ray computed tomography. To enable their fundamental work for an advantageous diagnostic application in medicine a new generation of polydentate W3O2 complexes with improved hydrolytical stability has been synthesized and characterized. The applicability as new metal based contrast agent has been demonstrated in a computed tomography angiography animal study with increased signal intensity. Especially the bis tridentate W3O2 complexes with their reduced stereochemical complexity represent a promising new class in the field of X-ray contrast agents.
引用
收藏
页码:111 / 118
页数:8
相关论文
共 50 条
  • [41] NEW SCINTILLATORS FOR X-RAY COMPUTED-TOMOGRAPHY
    GRABMAIER, BC
    ROSSNER, W
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (01): : 43 - 45
  • [42] New Developments and Applications of X-Ray Computed Tomography
    Zhu, Lei
    CURRENT MEDICAL IMAGING REVIEWS, 2010, 6 (02) : 60 - 60
  • [43] A new scanning technique for X-ray computed tomography
    Nukaga, Jun
    Kitazawa, So
    Kamimura, Hiroshi
    NDT & E INTERNATIONAL, 2008, 41 (07) : 564 - 569
  • [44] Contrast Improvement of Biodegradable Stents for X-ray Computed Tomography Visualization
    Winters, James
    Bennett, James
    Guelcher, Manfred
    Mathur, Anthony
    Martin, John
    Fahmy, Tarek
    Sinusas, Albert
    CIRCULATION, 2014, 130
  • [45] Developments in X-Ray Contrast Media and the Potential Impact on Computed Tomography
    Schoeckel, Laura
    Jost, Gregor
    Seidensticker, Peter
    Lengsfeld, Philipp
    Palkowitsch, Petra
    Pietsch, Hubertus
    INVESTIGATIVE RADIOLOGY, 2020, 55 (09) : 592 - 597
  • [46] Recent observations with phase-contrast X-ray computed tomography
    Momose, A
    Takeda, T
    Itai, Y
    Tu, JH
    Hirano, K
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 188 - 195
  • [47] Helical differential X-ray phase-contrast computed tomography
    Fu, Jian
    Willner, Marian
    Chen, Liyuan
    Tan, Renbo
    Achterhold, Klaus
    Bech, Martin
    Herzen, Julia
    Kunka, Danays
    Mohr, Juergen
    Pfeiffer, Franz
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03): : 374 - 379
  • [48] Phase-contrast X-ray computed tomography for biological imaging
    Momose, A
    Takeda, T
    Itai, Y
    DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 : 120 - 129
  • [49] Beam hardening in x-ray differential phase contrast computed tomography
    Bevins, Nicholas
    Zambelli, Joseph
    Li, Ke
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [50] VIDEO BASED X-RAY COMPUTED-TOMOGRAPHY
    QU, LZ
    NALCIOGLU, O
    ROECK, WW
    RABBANI, B
    COLMAN, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 527 - 530