Unilateral versus bilateral stent insertion for malignant hilar biliary obstruction

被引:31
|
作者
Chang, Gang [1 ]
Xia, Feng-Fei [1 ]
Li, Hong-Fu [1 ]
Niu, Su [2 ]
Xu, Yuan-Shun [3 ]
机构
[1] Binzhou Peoples Hosp, Dept Intervent Vasc Surg, 7 Huang He Rd, Binzhou 256600, Peoples R China
[2] Xuzhou Cent Hosp, Dept Intervent Radiol, 199 South Jie Fang Rd, Xuzhou 221009, Peoples R China
[3] Xuzhou Cent Hosp, Dept Radiol, 199 South Jie Fang Rd, Xuzhou 221009, Peoples R China
关键词
Unilateral stent insertion; Bilateral stent insertio; Hilar biliary obstruction; EXPANDABLE METAL STENTS; SIDE-BY-SIDE; CHOLANGIOCARCINOMA; MANAGEMENT; PLACEMENT; DEPLOYMENT; OCCLUSION; JAUNDICE; EFFICACY; PATENCY;
D O I
10.1007/s00261-017-1174-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the clinical efficiency and long-term outcomes between unilateral and bilateral stent insertion in patients with malignant hilar biliary obstruction. Methods: From August 2012 to February 2016, 63 consecutive patients with malignant hilar biliary obstruction were treated with unilateral or bilateral stent insertion at our center. The bilateral stents were inserted using the side-by-side technique. The clinical efficiency and long-term outcomes were compared between the two groups. Results: Unilateral and bilateral stent insertions were successfully performed in 31 of 33 and 27 of 30 patients, respectively (P = 0.912). No procedure-related complication occurred. Clinical success was achieved in 29 of 31 patients in the unilateral stent group and in 26 of 27 patients in the bilateral stent group (P = 0.637). During the follow-up, re-obstruction of stent occurred in five patients in the unilateral stent group and in three patients in the bilateral stent group (P = 0.58). The significant differences were not observed in the stent patency time (368 vs. 387 days, P = 0.685) and survival (200 vs. 198 days, P = 0.751) between two groups. Based on the univariate and multivariate analyses, the independent risk factors for decreasing the survival time included higher Eastern Cooperative Oncology Group performance status (P = 0.018), higher alanine aminotransferase level (P = 0.009), and absence of anticancer treatment after stent insertion (P = 0.002). Conclusion: Compared to bilateral stent insertion for malignant hilar biliary obstruction, unilateral stent insertion can provide comparable clinical efficiency and long-term outcomes.
引用
收藏
页码:2745 / 2751
页数:7
相关论文
共 50 条
  • [11] UNILATERAL VERSUS BILATERAL DRAINAGE USING SELF-EXPANDABLE METALLIC STENT FOR UNRESECTABLE HILAR BILIARY OBSTRUCTION
    Iwano, Hirotoshi
    Ryozawa, Shomei
    Ishigaki, Noriko
    Taba, Kumiko
    Senyo, Manabu
    Yoshida, Kanako
    Sakaida, Isao
    DIGESTIVE ENDOSCOPY, 2011, 23 (01) : 43 - 48
  • [12] Unilateral Versus Bilateral Endoscopic Metal and Plastic Stenting for Malignant Hilar Biliary Obstruction: a Single Center Study
    Yamamoto, Ryuichi
    Nishikawa, Ko
    Fujita, Tetsuro
    Otsuka, Takeshi
    Takahashi, Masatomo
    Chinen, Katsuya
    Kato, Shingo
    Nagoshi, Sumiko
    Yakabi, Koji
    GASTROINTESTINAL ENDOSCOPY, 2015, 81 (05) : AB362 - AB362
  • [13] Percutaneous insertion of a novel dedicated metal stent to treat malignant hilar biliary obstruction
    Francesco Cortese
    Fabrizio Acquafredda
    Andrea Mardighian
    Maria Teresa Zurlo
    Valentina Ferraro
    Riccardo Memeo
    Stavros Spiliopoulos
    Riccardo Inchingolo
    World Journal of Gastrointestinal Oncology, 2022, 14 (09) : 1833 - 1843
  • [14] Percutaneous insertion of a novel dedicated metal stent to treat malignant hilar biliary obstruction
    Cortese, Francesco
    Acquafredda, Fabrizio
    Mardighian, Andrea
    Zurlo, Maria Teresa
    Ferraro, Valentina
    Memeo, Riccardo
    Spiliopoulos, Stavros
    Inchingolo, Riccardo
    WORLD JOURNAL OF GASTROINTESTINAL ONCOLOGY, 2022, 14 (09) : 1833 - 1843
  • [15] Side-by-Side Versus Stent-in-Stent Deployment in Bilateral Endoscopic Metal Stenting for Malignant Hilar Biliary Obstruction
    Itaru Naitoh
    Kazuki Hayashi
    Takahiro Nakazawa
    Fumihiro Okumura
    Katsuyuki Miyabe
    Shuya Shimizu
    Michihiro Yoshida
    Hiroaki Yamashita
    Hirotaka Ohara
    Takashi Joh
    Digestive Diseases and Sciences, 2012, 57 : 3279 - 3285
  • [16] Side-by-side versus stent-in-stent bilateral stenting for malignant hilar biliary obstruction: a meta-analysis
    Chen, Liang
    Gao, Guo-Ming
    Li, Dong-Lu
    Chen, Zhong-Ke
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2022, 17 (02) : 279 - 288
  • [17] Side-by-Side Versus Stent-in-Stent Deployment in Bilateral Endoscopic Metal Stenting for Malignant Hilar Biliary Obstruction
    Naitoh, Itaru
    Hayashi, Kazuki
    Nakazawa, Takahiro
    Okumura, Fumihiro
    Miyabe, Katsuyuki
    Shimizu, Shuya
    Yoshida, Michihiro
    Yamashita, Hiroaki
    Ohara, Hirotaka
    Joh, Takashi
    DIGESTIVE DISEASES AND SCIENCES, 2012, 57 (12) : 3279 - 3285
  • [18] Endoscopic stenting for malignant hilar biliary obstruction: should it be metal or plastic and unilateral or bilateral?
    Hong, Wandong
    Sun, Xuecheng
    Zhu, Qihuai
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2013, 25 (09) : 1105 - 1112
  • [19] Bilateral Versus Unilateral Stenting for Malignant Hilar Obstruction: A Meta-Analysis
    Al Halabi, Shadi
    Sawas, Tarek
    Vargo, John
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 : S667 - S667
  • [20] Optimal stent placement for malignant hilar biliary obstruction
    Mosadeghi, Sasan
    Freeman, Martin L.
    GASTROINTESTINAL ENDOSCOPY, 2020, 92 (06) : 1275 - 1275