Confirmation of epidural catheter placement using nerve stimulation

被引:113
|
作者
Tsui, BCH [1 ]
Gupta, S [1 ]
Finucane, B [1 ]
机构
[1] Univ Alberta Hosp, Dept Anaesthesia, Walter Mackenzie Hlth Sci Ctr 3B232, Edmonton, AB T6G 2B7, Canada
关键词
D O I
10.1007/BF03012093
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose: To examine the reliability of low current electrical epidural stimulation to confirm epidural catheter placement. Methods: Forty patients with epidural catheters (19G Arrow Flextip plus) already in place for post-operative pain management were studied. An adapter (Arrow-Johans ECG Adapter) was attached to the connector of the epidural catheter. The epidural catheter and adapter were filled with normal saline. The cathode lead of the nerve stimulator was attached to the metal hub of the adapter. Catheter placement was judged to be correct or incorrect, depending on the presence or absence of truncal or limb movement to 1 Hz stimulation (1-10 mA). A standard test dose (3 ml lidocaine 1.5% with 1:200,000 epinephrine) was then injected. The efficacy of the epidural morphine was assessed independently. Results: The sensitivity and specificity of the test was 100% and 91.6% compared with the standard test dose. The positive and negative predictive value was 96% and 100%. In predicting the clinical effect of epidural morphine, the sensitivity and specificity was 96.1% and 76.99%. The positive and negative predictive value was 89% and 90%. The correlation of unilateral or bilateral motor response from the test and sensory response from the lidocaine test with sensitivity and specificity was 91.6% and 53.0%. The predictive value for unilateral response from was 61% and for bilateral was 88%. Conclusion: This study establishes this test as a simple, objective and reliable technique for confirmation of epidural catheter placement.
引用
收藏
页码:640 / 644
页数:5
相关论文
共 50 条
  • [21] Electrical stimulation test for epidural catheter placement after receiving intrathecal local anesthetic during a combined spinal-epidural technique for Cesarean delivery: confirmation of the spinal nerve root as epidural site of action
    Stewart, Malcolm
    Carvalho, Brendan
    Tsui, Ban C. H.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2020, 67 (04): : 498 - 499
  • [22] The placement of the epidural catheter at the predicted site by electrical stimulation test
    Hayatsu, K
    Tomita, M
    Fujihara, H
    Baba, H
    Yamakura, T
    Taga, K
    Shimoji, K
    ANESTHESIA AND ANALGESIA, 2001, 93 (04): : 1035 - 1039
  • [23] Inadvertent cervical epidural catheter placement via the caudal route using electrical stimulation
    Tsui, BCH
    Malherbe, S
    ANESTHESIA AND ANALGESIA, 2004, 99 (01): : 259 - 261
  • [24] Can Stimulation be used to confirm correct placement of epidural catheter?
    Andersen, C.
    Weber, S.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 : 59 - 60
  • [25] Lateral cervical epidural catheter placement using nerve stimulation for continuous unilateral upper extremity analgesia following a failed continuous peripheral nerve block
    Prusinkiewicz, C
    Lang, S
    Tsui, BCH
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (04) : 579 - 582
  • [26] Evaluation of electrical nerve stimulation for epidural catheter positioning in the dog
    Garcia-Pereira, Fernando L.
    Sanders, Robert
    Shih, Andre C.
    Sonea, Ioana M.
    Hauptman, Joseph G.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2013, 40 (05) : 546 - 550
  • [27] Transesophageal echocardiography for thoracic spinal cord imaging and confirmation of epidural catheter placement in pediatrics
    Hanada, Satoshi
    Reinking, Benjamin
    Kim, Sung
    Ueda, Kenichi
    JOURNAL OF CLINICAL ANESTHESIA, 2023, 91
  • [28] Lumbar plexus posterior approach: A catheter placement description using electrical nerve stimulation
    Pandin, PC
    Vandesteene, A
    d'Hollander, AA
    ANESTHESIA AND ANALGESIA, 2002, 95 (05): : 1428 - 1431
  • [29] Strategic placement of epidural catheter
    Shim, Jae-Hang
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2012, 63 (03) : 193 - 194
  • [30] Confirmation of caudal needle placement using nerve simulation
    Tsui, BCH
    Tarkkila, P
    Gupta, S
    Kearney, R
    ANESTHESIOLOGY, 1999, 91 (02) : 374 - 378