Purpose: To examine the reliability of low current electrical epidural stimulation to confirm epidural catheter placement. Methods: Forty patients with epidural catheters (19G Arrow Flextip plus) already in place for post-operative pain management were studied. An adapter (Arrow-Johans ECG Adapter) was attached to the connector of the epidural catheter. The epidural catheter and adapter were filled with normal saline. The cathode lead of the nerve stimulator was attached to the metal hub of the adapter. Catheter placement was judged to be correct or incorrect, depending on the presence or absence of truncal or limb movement to 1 Hz stimulation (1-10 mA). A standard test dose (3 ml lidocaine 1.5% with 1:200,000 epinephrine) was then injected. The efficacy of the epidural morphine was assessed independently. Results: The sensitivity and specificity of the test was 100% and 91.6% compared with the standard test dose. The positive and negative predictive value was 96% and 100%. In predicting the clinical effect of epidural morphine, the sensitivity and specificity was 96.1% and 76.99%. The positive and negative predictive value was 89% and 90%. The correlation of unilateral or bilateral motor response from the test and sensory response from the lidocaine test with sensitivity and specificity was 91.6% and 53.0%. The predictive value for unilateral response from was 61% and for bilateral was 88%. Conclusion: This study establishes this test as a simple, objective and reliable technique for confirmation of epidural catheter placement.
引用
收藏
页码:640 / 644
页数:5
相关论文
共 50 条
  • [1] Confirmation of epidural catheter placement using nerve stimulation
    Ban C. H. Tsui
    Sunil Gupta
    Brendan Finucane
    Canadian Journal of Anaesthesia, 1998, 45 : 640 - 644
  • [2] Confirmation of direct epidural catheter placement using nerve stimulation in pediatric anesthesia
    Goobie, SM
    Montgomery, CJ
    Basu, R
    McFadzean, J
    O'Connor, GJ
    Poskitt, K
    Tsui, BCH
    ANESTHESIA AND ANALGESIA, 2003, 97 (04): : 984 - 988
  • [3] Confirmation of epidural catheter placement in a quadriplegic patient using a nerve stimulator
    Sheila Riazi
    Ahtsham U. Niazi
    Paul S. Tumber
    Philip Peng
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2010, 57 : 276 - 277
  • [4] Confirmation of epidural catheter placement in a quadriplegic patient using a nerve stimulator
    Riazi, Sheila
    Niazi, Ahtsham U.
    Tumber, Paul S.
    Peng, Philip
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2010, 57 (03): : 276 - 277
  • [5] Detection of subdural placement of epidural catheter using nerve stimulation
    Ban C. H. Tsui
    Sunil Gupta
    Derek Emery
    Brendan Finucane
    Canadian Journal of Anaesthesia, 2000, 47 : 471 - 473
  • [6] Detection of subdural placement of an epidural catheter using nerve stimulation
    Tsui, BC
    Gupta, S
    Emery, D
    Finucane, B
    ANESTHESIA AND ANALGESIA, 2000, 90 (02): : U300 - U300
  • [7] Detection of subdural placement of epidural catheter using nerve stimulation
    Tsui, BCH
    Gupta, S
    Emery, D
    Finucane, B
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2000, 47 (05): : 471 - 473
  • [8] Determining epidural catheter location using nerve stimulation with radiological confirmation
    Tsui, BCH
    Guenther, C
    Emery, D
    Finucane, B
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2000, 25 (03) : 306 - 309
  • [9] Confirmation of epidural catheter placement
    Cressey, DM
    ANAESTHESIA, 1998, 53 (02) : 207 - 207
  • [10] Determination of epidural catheter placement using nerve stimulation in obstetric patients
    Tsui, BCH
    Gupta, S
    Finucane, B
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 1999, 24 (01) : 17 - 23