Design of X-ray interferometer for phase-contrast X-ray microtomography

被引:0
|
作者
Momose, A [1 ]
Hirano, K [1 ]
机构
[1] Hitachi Ltd, Adv Res Lab, Hatoyama, Saitama 3500395, Japan
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We tested an X-ray interferometer fabricated to improve the spatial resolution of phase-contrast X-ray computed tomography (CT). The main factor limiting the spatial resolution is the diffraction phenomenon in the crystal wafer of the interferometer. Improvement of the spatial resolution was attempted by thinning the wafer. A preliminary test was performed by checking interference patterns. Thinning the wafer from 1 to 0.24 mm showed clear improvement in the image quality.
引用
收藏
页码:98 / 103
页数:6
相关论文
共 50 条
  • [41] X-ray phase-contrast imaging: Phase reconstructions
    Wu, Xizeng
    Liu, Hong
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1786 - 1789
  • [42] Large-area phase-contrast X-ray imaging system based on a two-crystal X-ray interferometer
    Yoneyama, A
    Takeda, T
    Tsuchiya, Y
    Wu, J
    Lwin, TT
    Hyodo, K
    PORTABLE SYNCHROTRON LIGHT SOURCES AND ADVANCED APPLICATIONS, 2004, 716 : 22 - 25
  • [43] Differential X-ray phase-contrast imaging with a grating interferometer using a laboratory X-ray micro-focus tube
    Yoon, Kwon-Ha
    Ryu, Jong Hyun
    Jung, Chang Won
    Ryu, Cheol Woo
    Kim, Young Jo
    Kwon, Young Man
    Park, Miran
    Cho, Seungryong
    Chon, Kwon Su
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (12) : 2111 - 2116
  • [44] Differential X-ray phase-contrast imaging with a grating interferometer using a laboratory X-ray micro-focus tube
    Kwon-Ha Yoon
    Jong Hyun Ryu
    Chang Won Jung
    Cheol Woo Ryu
    Young Jo Kim
    Young Man Kwon
    Miran Park
    Seungryong Cho
    Kwon Su Chon
    Journal of the Korean Physical Society, 2014, 65 : 2111 - 2116
  • [45] High-Resolution X-Ray Phase-Contrast Imaging with a Grating Interferometer
    Lee, Seung Wook
    Kim, Youngju
    Lee, Seho
    Oh, Ohsung
    Xi, Yan
    Yang, Qingsong
    Cong, Wenxiang
    Wang, Ge
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 71 (09) : 538 - 542
  • [46] High-resolution X-ray phase-contrast imaging with a grating interferometer
    Seung Wook Lee
    Youngju Kim
    Seho Lee
    Ohsung Oh
    Yan Xi
    Qingsong Yang
    Wenxiang Cong
    Ge Wang
    Journal of the Korean Physical Society, 2017, 71 : 538 - 542
  • [47] Phase-contrast X-ray imaging with a triple-Bragg-case interferometer
    Koyama, I
    Yoshikawa, H
    Momose, A
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2003, 42 (1A-B): : L80 - L82
  • [48] Three-dimensional imaging of nerve tissue by x-ray phase-contrast microtomography
    Beckmann, F
    Heise, K
    Kölsch, B
    Bonse, U
    Rajewsky, MF
    Bartscher, M
    Biermann, T
    BIOPHYSICAL JOURNAL, 1999, 76 (01) : 98 - 102
  • [49] X-ray phase-contrast in vivo microtomography probes new aspects of Xenopus gastrulation
    Moosmann, Julian
    Ershov, Alexey
    Altapova, Venera
    Baumbach, Tilo
    Prasad, Maneeshi S.
    LaBonne, Carole
    Xiao, Xianghui
    Kashef, Jubin
    Hofmann, Ralf
    NATURE, 2013, 497 (7449) : 374 - +
  • [50] A novel approach to the study of bread porous structure: Phase-contrast x-ray microtomography
    Falcone, PM
    Baiano, A
    Zanini, F
    Mancini, L
    Tromba, G
    Montanari, F
    Del Nobile, MA
    JOURNAL OF FOOD SCIENCE, 2004, 69 (01) : E38 - E43