Flow-through electrochemical cell for accurate pH measurements at temperatures up to 400°C

被引:40
|
作者
Lvov, SN [1 ]
Zhou, XY [1 ]
Macdonald, DD [1 ]
机构
[1] Penn State Univ, Ctr Adv Mat, University Pk, PA 16801 USA
基金
美国国家科学基金会;
关键词
flow-through electrochemical cell; pH measurements; high temperature subcritical and supercritical aqueous solutions;
D O I
10.1016/S0022-0728(98)00409-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a flow-through electrochemical cell (FTEC) and demonstrated that it operates successfully in both subcritical and supercritical aqueous environments at temperatures up to 400 degrees C. The FTEC consists of a previously developed flow-through external (Ag\AgCl) pressure-balanced reference electrode (FTEPBRE) (Lvov et al., J. Electroanal. Chem. 444 (1998) 186) and a modified flow-through platinum hydrogen electrode (FTPHE). The experimental measurements have been carried out for two solutions: (1) 10(-3) mol kg(-1) HCl + 10(-1) mol kg(-1) NaCl and (2) 10(-2) mol kg(-1) HCl + 10(-1) mol kg(-1) NaCl at flow rates between 0.1 and 1.4 cm(3) min(-1) and at temperatures of 25 degrees C (18.7 MPa), 200 degrees C (23.8 MPa), 350 degrees C (24.2 MPa), and 400 degrees C (25.3 MPa). We have also carried out a detailed irreversible thermodynamic analysis of the FTEC and estimated different significant contributions to the measured potentials. Comparison of experimentally observed and theoretically calculated pH values shows an ability to use the FTEC for high precision potentiometric and pH measurements. We conclude that high temperature pH measurements with accuracy better than +/- 0.03 logarithmic units can now be accomplished. Also, we assume that valuable streaming potential data can be obtained using the FTEC for estimating the surface charge (zeta potential) on the oxide material capillary tube in hydrothermal solutions at temperatures up to 400 degrees C. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:146 / 156
页数:11
相关论文
共 50 条
  • [31] Measurements and Modeling of III-V Solar Cells at High Temperatures up to 400 °C
    Perl, Emmett E.
    Simon, John
    Geisz, John F.
    Lee, Minjoo Larry
    Friedman, Daniel J.
    Steiner, Myles A.
    IEEE JOURNAL OF PHOTOVOLTAICS, 2016, 6 (05): : 1345 - 1352
  • [32] THEORETICAL COMPARISON OF THE PERFORMANCE OF ELECTROCHEMICAL FLOW-THROUGH DETECTORS
    HANEKAMP, HB
    DEJONG, HG
    ANALYTICA CHIMICA ACTA, 1982, 135 (02) : 351 - 354
  • [33] ELECTROCHEMICAL FLOW-THROUGH DETECTOR WITH LEAD DIOXIDE ELECTRODE
    GRUNDLER, P
    ZEITSCHRIFT FUR CHEMIE, 1983, 23 (07): : 261 - 261
  • [34] ELECTROCHEMICAL REDUCTION OF OXYGEN AT A POROUS FLOW-THROUGH ELECTRODE
    KHALIFA, H
    ATEYA, BG
    ARAFAT, EAS
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1977, 81 (02): : 301 - 307
  • [35] THE BUBBLE ELECTRODE - A NEW ELECTROCHEMICAL FLOW-THROUGH DETECTOR
    SCHOLZ, F
    HENRION, G
    ZEITSCHRIFT FUR CHEMIE, 1983, 23 (04): : 152 - 153
  • [36] Flow-through electrochemical immunoassay for targeted bacteria detection
    Chorti, Parthena
    Kazi, Abbas Parvez
    Haque, Al-Monsur Jiaul
    Wiederoder, Michael
    Christodouleas, Dionysios C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 351
  • [37] THEORETICAL CONSIDERATIONS ON THE PERFORMANCE OF ELECTROCHEMICAL FLOW-THROUGH DETECTORS
    HANEKAMP, HB
    VANNIEUWKERK, HJ
    ANALYTICA CHIMICA ACTA, 1980, 121 (DEC) : 13 - 22
  • [38] A membrane free electrochemical cell using porous flow-through graphite felt electrodes
    Chul Bae
    Harun Chakrabarti
    Edward Roberts
    Journal of Applied Electrochemistry, 2008, 38 : 637 - 644
  • [39] A membrane free electrochemical cell using porous flow-through graphite felt electrodes
    Bae, Chul
    Chakrabarti, Harun
    Roberts, Edward
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2008, 38 (05) : 637 - 644
  • [40] Separation of lead and zinc using a flow-through electrochemical cell and their simultaneous spectrophotometric determination
    Watanabe, K
    Katou, Y
    Itagaki, M
    BUNSEKI KAGAKU, 2005, 54 (02) : 121 - 126