Base isolation for retrofitting historic buildings: Evaluation of seismic performance through experimental investigation

被引:36
|
作者
De Luca, A
Mele, E
Molina, J
Verzeletti, G
Pinto, AV
机构
[1] Univ Naples Federico II, Dipartimento Anal & Progettaz Strutturale, I-80125 Naples, Italy
[2] Commiss European Communities, Joint Res Ctr, ISIS, ELSA Lab, I-21020 Ispra, VA, Italy
来源
关键词
historic buildings; seismic retrofit; base isolation system;
D O I
10.1002/eqe.54
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental test program on a full-scale model representing a sub-assemblage of the cloister facade of the Sao Vicente de Fora monastery, retrofitted through base isolation, has been recently carried out at the European Laboratory for Structural Assessment of the Joint Research Centre of the European Commission. In this paper an overview of the laboratory model and the experimental results is provided. In particular, firstly the test model is described, including the geometry and mechanical properties of the masonry specimen and the design of the isolation devices; then the testing method and the substructuring of the isolation system are described and the seismic inputs adopted for the pseudo-dynamic tests are defined. Finally, the experimental results are discussed and compared to the analogous results obtained on the 'as is', fixed-base sub-assemblage model. The implications of the test outcomes are emphasized and developments of this research line are presented. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:1125 / 1145
页数:21
相关论文
共 50 条
  • [21] Seismic performance evaluation of CFS strap-braced buildings through experimental tests
    Landolfo, Raffaele
    Campiche, Alessia
    Iuorio, Ornella
    Fiorino, Luigi
    [J]. STRUCTURES, 2021, 33 : 3040 - 3054
  • [22] SEISMIC BASE ISOLATION OF ASYMMETRIC SHEAR BUILDINGS
    EISENBERGER, M
    RUTENBERG, A
    [J]. ENGINEERING STRUCTURES, 1986, 8 (01) : 2 - 8
  • [23] Seismic retrofitting by base-isolation of r.c. framed buildings exposed to different fire scenarios
    Mazza, Fabio
    Mazza, Mirko
    [J]. EARTHQUAKES AND STRUCTURES, 2017, 13 (03) : 267 - 277
  • [24] A negative stiffness dynamic base absorber for seismic retrofitting of residential buildings
    Mantakas, Antonios G.
    Kapasakalis, Konstantinos A.
    Alvertos, Antonios E.
    Antoniadis, Ioannis A.
    Sapountzakis, Evangelos J.
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (12):
  • [25] Seismic Base Isolation of a Strategic Historic Masonry Building
    Zordan, Tobia
    Romano, Alessandra
    Parisi, Fulvio
    [J]. SEISMIC ISOLATION, ENERGY DISSIPATION AND ACTIVE VIBRATION CONTROL OF STRUCTURES, 17WCSI 2022, 2023, 309 : 524 - 531
  • [26] Seismic retrofitting of a historic building by using an isolation system with a weak restoring force
    Zhang, Ruifu
    Wu, Minjun
    Lu, Wensheng
    Li, Xuan
    Lu, Xilin
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 148
  • [27] Evaluation of Benefits for Integrated Seismic and Energy Retrofitting for the Existing Buildings
    Manganelli, Benedetto
    Mastroberti, Monica
    Vona, Marco
    [J]. NEW METROPOLITAN PERSPECTIVES: LOCAL KNOWLEDGE AND INNOVATION DYNAMICS TOWARDS TERRITORY ATTRACTIVENESS THROUGH THE IMPLEMENTATION OF HORIZON/E2020/AGENDA2030, VOL 2, 2019, 101 : 654 - 662
  • [28] A refined procedure for seismic evaluation and retrofitting of reinforced concrete buildings
    Shendkar, Mangeshkumar R.
    Kontoni, Denise-Penelope N.
    Kumar, Ramancharla Pradeep
    Farghaly, Ahmed Abdelraheem
    Mandal, Sasankasekhar
    Maiti, Pabitra Ranjan
    [J]. CURRENT SCIENCE, 2022, 123 (08): : 1020 - 1030
  • [29] Experimental Seismic Performance Evaluation of Unreinforced Brick Masonry Buildings
    Shahzada, Khan
    Khan, Akhtar Naeem
    Elnashai, Amr S.
    Ashraf, Mohammad
    Javed, Muhammad
    Naseer, Amjad
    Alam, Bashir
    [J]. EARTHQUAKE SPECTRA, 2012, 28 (03) : 1269 - 1290
  • [30] Retrofitting Existing Masonry Structures by Using Seismic Base Isolation System
    Rawa Asaad
    Ammar Kaadan
    [J]. Arabian Journal for Science and Engineering, 2024, 49 : 5243 - 5254