Continuous noninvasive hemoglobin monitoring: ready for prime time?

被引:8
|
作者
Suehiro, Koichi [1 ]
Joosten, Alexandre [1 ]
Alexander, Brenton [1 ]
Cannesson, Maxime [1 ]
机构
[1] Univ Calif Irvine, Dept Anesthesiol & Perioperat Care, Orange, CA 92868 USA
关键词
accuracy; bleeding; hemoglobin; noninvasive; transfusion; PULSE CO-OXIMETRY; ACCURACY; TRANSFUSION; COOXIMETER; PRECISION; HEMOCUE; RISK; CELL;
D O I
10.1097/MCC.0000000000000197
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of review Determination of hemoglobin (Hb) concentration is essential for the detection of anemia and hemorrhage and is widely used to evaluate a patient for a possible blood transfusion. Although commonly accepted as intrinsic to the process, traditional laboratory measurements of Hb are invasive, intermittent, and time-consuming. Noninvasive Hb (NIHb)-monitoring devices have recently become available and promise the potential for detecting sudden changes in a patient's Hb level. In addition to reduced delays in clinical intervention, these devices also allow for a reduction in patient discomfort, infection risk, required personnel, and long-term costs. Unfortunately, it has been shown that many clinical factors can influence their accuracy. Recent findings Many studies have been published on the accuracy and precision of NIHb-monitoring devices in various clinical settings. A recent meta-analysis has shown a small mean difference but wide limits of agreement between NIHb and laboratory measurements, indicating that caution should be used by physicians when making clinical decisions based on this device. Summary NIHb measurements may currently be considered to be a supplemental tool for monitoring trends in Hb concentration, but are not currently developed enough to replace an invasive approach. Moreover, further studies are still required before implementing NIHb in the clinical decision-making process. Specifically, no studies have demonstrated that this technology improves clinical outcomes or patient safety.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
  • [21] Continuous noninvasive hemoglobin monitoring: The standard of care and future impact
    Kost, Gerald J.
    Tran, Nam K.
    CRITICAL CARE MEDICINE, 2011, 39 (10) : 2369 - 2371
  • [22] Accuracy of continuous and noninvasive hemoglobin monitoring during prolonged surgery
    Sazuka, S.
    Koshika, K.
    Watanabe, Y.
    Ouchi, T.
    Serita, R.
    Koitabashi, T.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 39 - 39
  • [23] Continuous, noninvasive monitoring of total hemoglobin concentration by an optoacoustic technique
    Esenaliev, RO
    Petrov, YY
    Hartrumpf, O
    Deyo, DJ
    Prough, DS
    APPLIED OPTICS, 2004, 43 (17) : 3401 - 3407
  • [24] Continuous Noninvasive Hemoglobin Monitoring During Complex Spine Surgery
    Berkow, Lauren
    Rotolo, Stephanie
    Mirski, Erin
    ANESTHESIA AND ANALGESIA, 2011, 113 (06): : 1396 - 1402
  • [25] Noninvasive continuous hemoglobin monitoring of blood transfusion in obstetric procedures
    Beleta, Mohamed Ibrahim
    Abdallah, Shady Rady
    Hammad, Yehia Mohamed
    Yahia, Hossam Eldin Mostafa
    Ali, Ashraf Abd ElMawgood
    Mohamed, Ahmed Abdallah
    AbdElhameed, Bassant Mohamed
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2022, 38 (01): : 701 - 708
  • [26] Continuous intra-abdominal pressure: is it ready for prime time?
    Manu L. N. G. Malbrain
    Bart L. De Keulenaer
    Ashish K. Khanna
    Intensive Care Medicine, 2022, 48 : 1501 - 1504
  • [27] Continuous intra-abdominal pressure: is it ready for prime time?
    Malbrain, Manu L. N. G.
    De Keulenaer, Bart L.
    Khanna, Ashish K.
    INTENSIVE CARE MEDICINE, 2022, 48 (10) : 1501 - 1504
  • [28] Erratum to: Noninvasive ventilation for weaning in hypoxemic respiratory failure: not ready for prime time
    Franco Laghi
    Rafael Fernandez
    Intensive Care Medicine, 2013, 39 : 162 - 162
  • [29] Not ready for prime time
    Cyprych, G
    COMPUTER, 2002, 35 (08) : 7 - 7
  • [30] Not ready for prime time
    Isaacs, J
    BULLETIN OF THE ATOMIC SCIENTISTS, 2000, 56 (05) : 20 - 21