Protein analysis by membrane preconcentration capillary electrophoresis: systematic evaluation of parameters affecting preconcentration and separation

被引:38
|
作者
Rohde, E
Tomlinson, AJ
Johnson, DH
Naylor, S
机构
[1] Mayo Clin & Mayo Fdn, Dept Biochem & Mol Biol, Biomed Mass Spect Facil, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Ophthalmol, Clin Pharmacol Unit, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Dept Pharmacol, Clin Pharmacol Unit, Rochester, MN 55905 USA
关键词
preconcentration; proteins;
D O I
10.1016/S0378-4347(98)00209-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fast and efficient analysis of proteins in physiological fluids is of great interest to researchers and clinicians alike. Capillary electrophoresis (CE) has proven to be a potentially valuable tool for the separation of proteins in specimens. However, a generally acknowledged drawback of this technique is the limited sample volumes which can be loaded onto the CE capillary which results in a poor concentration limit of detection. In addition, matrix components in samples may also interfere with separation and detection of analytes. Membrane preconcentration-CE (mPC-CE) has proved to be effective in overcoming these problems. In this report, we describe the systematic evaluation of parameters affecting on-line preconcentration/clean-up and separation of protein mixtures by mPC-CE. Method development was carried out with a standard mixture of proteins (lysozyme, myoglobin, carbonic anhydrase, and human serum albumin). First, using MALDI-TOF-MS, membrane materials with cation-exchange (R-SO3H) or hydrophobic (C-2, C-8, C-18, SDB) characteristics were evaluated for their potential to retain proteins in mPC cartridges. Hydrophobic membranes were found most suitable for this application. Next, all mPC-CE analysis of protein samples were performed in polybrene coated capillaries and parameters affecting sample loading, washing and elution, such as the composition and volume of the elution solvent were investigated. Furthermore, to achieve optimal mPC-CE performance for the separation of protein mixtures parameters affecting postelution focusing and electrophoresis, including the composition of the background electrolyte and a trailing stacking buffer were varied. Optimal conditions for mPC-CE analysis of proteins using a C-2 impregnated membrane preconcentration (mPC) cartridge were achieved with a background electrolyte of 5% acetic acid and 2 mM ammonium acetate, 60 nl of 80% acetonitrile in H2O as an elution solvent, and 60 nl of 0.5% ammonium hydroxide as a trailing stacking buffer. The developed method was used successfully to separate proteins in aqueous humor, which contains numerous proteins in a complex matrix of salts. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:301 / 311
页数:11
相关论文
共 50 条
  • [1] Different strategies for the preconcentration and separation of parabens by capillary electrophoresis
    Maijo, Irene
    Borrull, Francesc
    Aguilar, Carme
    Calull, Marta
    ELECTROPHORESIS, 2013, 34 (03) : 363 - 373
  • [2] Preconcentration techniques in capillary electrophoresis
    L. A. Kartsova
    E. A. Bessonova
    Journal of Analytical Chemistry, 2009, 64 : 326 - 337
  • [3] Preconcentration techniques in capillary electrophoresis
    Kartsova, L. A.
    Bessonova, E. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 64 (04) : 326 - 337
  • [4] Systematic development of on-line membrane preconcentration capillary electrophoresis mass spectrometry for the analysis of peptide mixtures
    Tomlinson, AJ
    Naylor, S
    JOURNAL OF CAPILLARY ELECTROPHORESIS, 1995, 2 (05) : 225 - 233
  • [5] Comparison of protein mixtures in aqueous humor by membrane preconcentration capillary electrophoresis mass spectrometry
    Rohde, E
    Tomlinson, AJ
    Johnson, DH
    Naylor, S
    ELECTROPHORESIS, 1998, 19 (13) : 2361 - 2370
  • [6] Membrane preconcentration capillary electrophoresis mass spectrometry in the analysis of biologically derived metabolites and biopolymers
    Naylor, S
    Tomlinson, AJ
    BIOMEDICAL CHROMATOGRAPHY, 1996, 10 (06) : 325 - 330
  • [7] IMPROVED ONLINE MEMBRANE PRECONCENTRATION CAPILLARY ELECTROPHORESIS (MPC-CE)
    TOMLINSON, AJ
    BENSON, LM
    BRADDOCK, WD
    ODA, RP
    NAYLOR, S
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (06): : 381 - 383
  • [8] DEVELOPMENT OF A CAPILLARY ELECTROPHORESIS PRECONCENTRATION METHOD FOR THE ANALYSIS OF DIDEOXYADENOSINE TRIPHOSPHATE
    Mallampati, Swapna
    Wolfs, Kris
    Pendela, Murali Mohan
    Hoogmartens, Jos
    Van Schepdael, Ann
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2010, 33 (06) : 802 - 817
  • [9] ANALYSIS OF A DILUTE SAMPLE BY CAPILLARY ZONE ELECTROPHORESIS WITH ISOTACHOPHORETIC PRECONCENTRATION
    HIROKAWA, T
    OHMORI, A
    KISO, Y
    JOURNAL OF CHROMATOGRAPHY, 1993, 634 (01): : 101 - 106
  • [10] ON-LINE PRECONCENTRATION IN CAPILLARY ELECTROPHORESIS FOR ANALYSIS OF AGROCHEMICAL RESIDUES
    Fang, Rou
    Yi, Ling-Xiao
    Shao, Yu-Xiu
    Zhang, Li
    Chen, Guan-Hua
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (10) : 1465 - 1497