Systematic development of on-line membrane preconcentration capillary electrophoresis mass spectrometry for the analysis of peptide mixtures

被引:0
|
作者
Tomlinson, AJ
Naylor, S
机构
[1] MAYO CLIN,BIOMED MASS SPECTROMETRY FACIL,ROCHESTER,MN
[2] MAYO CLIN,DEPT BIOCHEM & MOLEC BIOL,ROCHESTER,MN
[3] MAYO CLIN,DEPT PHARMACOL,ROCHESTER,MN
[4] MAYO CLIN,CLIN PHARMACOL UNIT,ROCHESTER,MN
关键词
capillary electrophoresis; mass spectrometry; membrane preconcentration CE; peptides; on-line sample concentration; sample cleanup; transient isotachophoresis;
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A unique method for analyte preconcentration on-line with CE and CE-mass spectrometry (CE-MS) that can concentrate large sample volumes (>100 mu L) is described. A cartridge containing a suitably impregnated membrane is installed at the inlet of the CE capillary, and this approach is termed membrane preconcentration-CE-MS (mPC-CE-MS). The authors describe the mPC-CE-MS analysis of dilute peptide mixtures (similar to 1 fmol/nL) that are concentrated onto the membrane and subsequently subjected to on-line sample cleanup prior to elution and ultimately CE-MS. The systematic development of mPC-CE-MS is demonstrated, and the necessity of minimizing the adsorptive phase in order to ensure efficient peptide analyte recovery and minimization of organic elution solvent is described. The authors compare and contrast mPC-CE and mPC-CE-MS with PC-CE and solid-phase preconcentration-CE-MS (PC-CE-MS), and describe several limitations of the latter approach, which includes analyte zone broadening and compromised analyte resolution. Finally, the authors show that the use of mPC-CE-MS in conjunction with transient isotachophoresis after the peptides have been eluted from the adsorptive membrane affords optimal performance, and theoretical plate values of up to similar to 2.6 x 10(6) are observed for the analysis of a nine-component peptide mixture using this approach. It is conservatively estimated that, in conjunction with an MS array detector, a practical concentration limit of detection (CLOD) for peptides is similar to 500 fg-1 pg/mL using mPC-CE-MS.
引用
收藏
页码:225 / 233
页数:9
相关论文
共 50 条
  • [1] Comparison of protein mixtures in aqueous humor by membrane preconcentration capillary electrophoresis mass spectrometry
    Rohde, E
    Tomlinson, AJ
    Johnson, DH
    Naylor, S
    ELECTROPHORESIS, 1998, 19 (13) : 2361 - 2370
  • [2] On-line capillary electrophoresis-mass spectrometry for the analysis of biomolecules
    Hernández-Borges, J
    Neusüss, C
    Cifuentes, A
    Pelzing, M
    ELECTROPHORESIS, 2004, 25 (14) : 2257 - 2281
  • [3] On-line capillary electrophoresis mass spectrometry for determination of peptide mixture and protein mixture
    Zhou, GH
    Luo, GA
    Zhou, KY
    Gu, ZL
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1998, 19 (03): : 353 - 358
  • [4] ON-LINE PRECONCENTRATION IN CAPILLARY ELECTROPHORESIS FOR ANALYSIS OF AGROCHEMICAL RESIDUES
    Fang, Rou
    Yi, Ling-Xiao
    Shao, Yu-Xiu
    Zhang, Li
    Chen, Guan-Hua
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (10) : 1465 - 1497
  • [5] On-line preconcentration methods for capillary electrophoresis
    Osbourn, DM
    Weiss, DJ
    Lunte, CE
    ELECTROPHORESIS, 2000, 21 (14) : 2768 - 2779
  • [6] On-line preconcentration techniques in capillary electrophoresis
    Horáková, J
    Maier, V
    Sevcík, J
    CHEMICKE LISTY, 2006, 100 (03): : 163 - 168
  • [7] On-line preconcentration of sample in capillary electrophoresis
    Hui, X
    Ying, Z
    Yu, XD
    Chen, HY
    PROGRESS IN CHEMISTRY, 2005, 17 (03) : 377 - 383
  • [8] On-line capillary electrophoresis-electrospray mass spectrometry for the analysis of pharmaceuticals
    Cherkaoui, S
    Rudaz, S
    Varesio, E
    Veuthey, JL
    CHIMIA, 1999, 53 (10) : 501 - 505
  • [9] Development of an on-line preconcentration method for the analysis of pathogenic lipopolysaccharides using capillary electrophoresis - electrospray mass spectrometry - Application to small colony isolates
    Li, J
    Thibault, P
    Martin, A
    Richards, JC
    Wakarchuk, WW
    van der Wilp, W
    JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) : 325 - 336
  • [10] Membrane preconcentration capillary electrophoresis mass spectrometry in the analysis of biologically derived metabolites and biopolymers
    Naylor, S
    Tomlinson, AJ
    BIOMEDICAL CHROMATOGRAPHY, 1996, 10 (06) : 325 - 330