Systematic development of on-line membrane preconcentration capillary electrophoresis mass spectrometry for the analysis of peptide mixtures

被引:0
|
作者
Tomlinson, AJ
Naylor, S
机构
[1] MAYO CLIN,BIOMED MASS SPECTROMETRY FACIL,ROCHESTER,MN
[2] MAYO CLIN,DEPT BIOCHEM & MOLEC BIOL,ROCHESTER,MN
[3] MAYO CLIN,DEPT PHARMACOL,ROCHESTER,MN
[4] MAYO CLIN,CLIN PHARMACOL UNIT,ROCHESTER,MN
关键词
capillary electrophoresis; mass spectrometry; membrane preconcentration CE; peptides; on-line sample concentration; sample cleanup; transient isotachophoresis;
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A unique method for analyte preconcentration on-line with CE and CE-mass spectrometry (CE-MS) that can concentrate large sample volumes (>100 mu L) is described. A cartridge containing a suitably impregnated membrane is installed at the inlet of the CE capillary, and this approach is termed membrane preconcentration-CE-MS (mPC-CE-MS). The authors describe the mPC-CE-MS analysis of dilute peptide mixtures (similar to 1 fmol/nL) that are concentrated onto the membrane and subsequently subjected to on-line sample cleanup prior to elution and ultimately CE-MS. The systematic development of mPC-CE-MS is demonstrated, and the necessity of minimizing the adsorptive phase in order to ensure efficient peptide analyte recovery and minimization of organic elution solvent is described. The authors compare and contrast mPC-CE and mPC-CE-MS with PC-CE and solid-phase preconcentration-CE-MS (PC-CE-MS), and describe several limitations of the latter approach, which includes analyte zone broadening and compromised analyte resolution. Finally, the authors show that the use of mPC-CE-MS in conjunction with transient isotachophoresis after the peptides have been eluted from the adsorptive membrane affords optimal performance, and theoretical plate values of up to similar to 2.6 x 10(6) are observed for the analysis of a nine-component peptide mixture using this approach. It is conservatively estimated that, in conjunction with an MS array detector, a practical concentration limit of detection (CLOD) for peptides is similar to 500 fg-1 pg/mL using mPC-CE-MS.
引用
收藏
页码:225 / 233
页数:9
相关论文
共 50 条
  • [21] On-line preconcentration and quantitative analysis of peptide hormone of brain and intestine using on-column transient isotachophoresis coupled with capillary electrophoresis/electrospray ionization mass spectrometry
    Xia, Shifei
    Zhang, Lan
    Qiu, Bin
    Lu, Minghua
    Chi, Yuwu
    Chen, Guonan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (23) : 3719 - 3726
  • [22] Complementary on-line preconcentration strategies for steroids by capillary electrophoresis
    Britz-McKibbin, P
    Ichihashi, T
    Tsubota, K
    Chen, DDY
    Terabe, S
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1013 (1-2) : 65 - 76
  • [23] On-line Preconcentration on pH Boundary - the Beauty of Capillary Electrophoresis
    Petr, Jan
    Maier, Vitezslav
    Znaleziona, Joanna
    Vitkova, Katerina
    Ranc, Vaclav
    Sevcik, Juraj
    CHEMICKE LISTY, 2009, 103 (08): : 661 - 666
  • [24] On-line sample preconcentration in capillary electrophoresis Fundamentals and applications
    Simpson, Steven L., Jr.
    Quirino, Joselito P.
    Terabe, Shigeru
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) : 504 - 541
  • [25] Analysis of lysozyme in cheese samples by on-line combination of capillary zone electrophoresis and mass spectrometry
    Kondekova, Monika
    Maier, Vitezslav
    Ginterova, Pavlina
    Marak, Jozef
    Sevcik, Juraj
    FOOD CHEMISTRY, 2014, 153 : 398 - 404
  • [26] On-line capillary electrophoresis-electrospray mass spectrometry for the stereoselective analysis of drugs and metabolites
    Cherkaoui, S
    Rudaz, S
    Varesio, E
    Veuthey, JL
    ELECTROPHORESIS, 2001, 22 (15) : 3308 - 3315
  • [27] Analysis of Charged Cyclodextrin Derivatives by On-Line Capillary Electrophoresis-Ionspray-Mass Spectrometry
    Yoshihide Tanaka
    Yasuhiro Kishimoto
    Shigeru Terabe
    Analytical Sciences, 1998, 14 : 383 - 388
  • [28] Evaluation of on-line solid-phase extraction capillary electrophoresis - mass spectrometry with a nanoliter valve for the analysis of peptide biomarkers
    Pero-Gascon, Roger
    Benavente, Fernando
    Neusuess, Christian
    Sanz-Nebot, Victoria
    ANALYTICA CHIMICA ACTA, 2020, 1140 (1140) : 1 - 9
  • [29] Analysis of histones by on-line capillary zone electrophoresis-electrospray ionisation mass spectrometry
    Aguilar, C
    Hofte, AJP
    Tjaden, UR
    van der Greef, J
    JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) : 57 - 67
  • [30] On-line capillary electrophoresis-electrospray ionization mass spectrometry analysis of urinary porphyrins
    Li, Jinhua
    Chan, Wan
    Cai, Zongwei
    ELECTROPHORESIS, 2009, 30 (10) : 1790 - 1797