Die-off of E. coli as fecal indicator organism on different surfaces after urban floods
被引:3
|
作者:
Scoullos, Iosif Marios
论文数: 0引用数: 0
h-index: 0
机构:
IHE Delft Inst Water Educ, Environm Engn & Water Technol Dept, POB 3015, NL-2601 DA Delft, Netherlands
Delft Univ Technol, Dept Biotechnol, Maasweg 9, NL-2629 HZ Delft, NetherlandsIHE Delft Inst Water Educ, Environm Engn & Water Technol Dept, POB 3015, NL-2601 DA Delft, Netherlands
Scoullos, Iosif Marios
[1
,2
]
Vazquez, Carlos M. Lopez
论文数: 0引用数: 0
h-index: 0
机构:
IHE Delft Inst Water Educ, Environm Engn & Water Technol Dept, POB 3015, NL-2601 DA Delft, NetherlandsIHE Delft Inst Water Educ, Environm Engn & Water Technol Dept, POB 3015, NL-2601 DA Delft, Netherlands
Vazquez, Carlos M. Lopez
[1
]
van de Vossenberg, Jack
论文数: 0引用数: 0
h-index: 0
机构:
IHE Delft Inst Water Educ, Environm Engn & Water Technol Dept, POB 3015, NL-2601 DA Delft, NetherlandsIHE Delft Inst Water Educ, Environm Engn & Water Technol Dept, POB 3015, NL-2601 DA Delft, Netherlands
van de Vossenberg, Jack
[1
]
Brdjanovic, Damir
论文数: 0引用数: 0
h-index: 0
机构:
IHE Delft Inst Water Educ, Environm Engn & Water Technol Dept, POB 3015, NL-2601 DA Delft, Netherlands
Delft Univ Technol, Dept Biotechnol, Maasweg 9, NL-2629 HZ Delft, NetherlandsIHE Delft Inst Water Educ, Environm Engn & Water Technol Dept, POB 3015, NL-2601 DA Delft, Netherlands
Brdjanovic, Damir
[1
,2
]
机构:
[1] IHE Delft Inst Water Educ, Environm Engn & Water Technol Dept, POB 3015, NL-2601 DA Delft, Netherlands
A better understanding of the effects of different urban and recreational surfaces on the die-off of water-borne pathogens that can cause infections after urban floods if released from surcharged combined sewers and other sources of fecal contamination is needed. The die-off of fecal indicator Escherichia coli was studied under controlled exposure to simulated sunlight on a range of different surfaces found in urban environments: gravel, sand, asphalt, pavement blocks, concrete, playground rubber tiles and grass, using glass as control. The surfaces were inoculated with artificial flooding water containing 10(5) colony forming units (CFU) of E. coli per mL and sampled periodically using the sterile cotton swab technique, after lowering the water level. The results show that dark inactivation was not statistically significant for any surface, suggesting that chemical composition and pH (varying between 6.5 +/- 0.8 and 9.2 +/- 0.4) did not affect the die-off rates. The highest light-induced die-off rates for E. coli after the floodwater recession, observed on rubber (> 3.46 h(-1)) and asphalt (2.7 h(-1)), were attributed to temperature stress and loss of surface moisture.