A practical design and field errors analysis of a merged APPLE-Knot undulator for High Energy Photon Source

被引:10
|
作者
Yang, Yanwei [1 ,2 ]
Li, Xiaoyu [1 ]
Lu, Huihua [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Key Lab Particle Accelerat Phys & Technol, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
HEPS; APPLE-Knot undulator; Field integrals correction; Field errors;
D O I
10.1016/j.nima.2021.165579
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Users of HEPS require polarization adjustable and high-flux synchrotron radiation with energy of 100-2000 eV. To achieve 100 eV photon energy at HEPS, a 6 GeV storage ring, the problem of on-axis heat load becomes a significant challenge for users. A new type of four-row merged APPLE-Knot undulator recently proposed seems to be the most effective solution to reduce on-axis power density. However, as an undulator with such complex magnetization orientation distribution of magnetic blocks, its field integrals correction and the effect of field errors on the radiation performance are different from that of conventional EPU. Whether it can realize its field integrals correction and perform as well as in theory with field errors has become a concern. Here, a set of field integrals correction schemes is reported and field errors analysis has been done. A general method for evaluating the effect of magnetization orientation deviation of the magnetic block on radiation performance is proposed. It can be used for any insertion device containing permanent magnetic magnets if necessary.
引用
收藏
页数:9
相关论文
共 49 条
  • [31] Design, construction and testing of the prototype cryogenic circulation centrifugal pump for the high energy photon source
    Han, Ruixiong
    Zhang, Xiangzhen
    Ge, Rui
    Geng, Haipeng
    Xu, Hao
    Lin, Hao
    Jiang, Yongcheng
    Zhang, Jiehao
    Sang, Minjing
    Zhao, Tongxian
    Zhang, Zhuo
    Ma, Changcheng
    Ye, Rui
    Yang, Xiaochen
    Chang, Zhengze
    Li, Mei
    Xu, Miaofu
    Sun, Liangrui
    Zhu, Keyu
    Li, Shaopeng
    CRYOGENICS, 2024, 142
  • [32] PRECISION WHITE-BEAM SLIT DESIGN FOR HIGH POWER-DENSITY X-RAY UNDULATOR BEAMLINES AT THE ADVANCED PHOTON SOURCE
    SHU, D
    BRITE, C
    NIAN, T
    YUN, W
    HAEFFNER, DR
    ALP, EE
    RYDING, D
    COLLINS, J
    LI, Y
    KUZAY, TM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1789 - 1791
  • [33] Hall sensor angle error and relative position calibrations for cryogenic permanent magnet undulator of high energy photon source test facility (HEPS-TF)
    Gong L.-L.
    Chen W.
    Kang W.
    Sun S.-C.
    Li Z.-Q.
    Zhang L.
    Yang Y.-F.
    Lu H.-H.
    Li X.-Y.
    Zhao S.-T.
    Zhang X.-Z.
    Sun Y.-J.
    Radiation Detection Technology and Methods, 2017, 1 (2)
  • [34] Statistical analysis of the limitation of half integer resonances on the available momentum acceptance of the High Energy Photon Source
    Jiao, Yi
    Duan, Zhe
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 841 : 97 - 103
  • [35] Repeatability and sensitivity characterization of the far-field high-energy diffraction microscopy instrument at the Advanced Photon Source
    Park, Jun Sang
    Sharma, Hemant
    Kenesei, Peter
    JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 : 1786 - 1800
  • [36] Design and Analysis of Dual Source Vertical Tunnel Field Effect Transistor for High Performance
    Soniya Badgujjar
    Girish Wadhwa
    Shailendra Singh
    Balwinder Raj
    Transactions on Electrical and Electronic Materials, 2020, 21 : 74 - 82
  • [37] Design and Analysis of Dual Source Vertical Tunnel Field Effect Transistor for High Performance
    Badgujjar, Soniya
    Wadhwa, Girish
    Singh, Shailendra
    Raj, Balwinder
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2020, 21 (01) : 74 - 82
  • [38] Dosimetric evaluation of a new design small volume detectors for small field high-energy photon beam
    Huh, H. Hyun Do
    Choi, C. Sang Hyoun
    Kim, K. Seong Hoon
    Kim, K. Kum Bae
    Ji, J. Young Hoon
    Lee, L. Chang Yeol
    Kim, K. Woo Chul
    Kim, K. Hun Jeong
    Min, M. Chul Kee
    Cho, C. Kwang Hwan
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S137 - S137
  • [39] Thermal performance analysis and cryogenic experimental measurements of the 166.6 MHz cavity cryomodule for the High Energy Photon Source
    Han, Ruixiong
    Ge, Rui
    Zhang, Pei
    Zhang, Xiangzhen
    Zhao, Tongxian
    Sun, Liangrui
    Zhang, Xinying
    Sang, Minjing
    Yang, Xiaochen
    Ye, Rui
    Guo, Lin
    Ma, Qiang
    Huang, Tongming
    Zhang, Jiehao
    Ma, Changcheng
    Zhou, Jianrong
    Chang, Zhengze
    Jiang, Yongcheng
    Zhang, Zhuo
    Xu, Miaofu
    Li, Mei
    Zhu, Keyu
    Li, Shaopeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2025, 1070
  • [40] In situ and operando structural analysis with high-energy X-rays at the Advanced Photon Source APS
    Ruett, Uta
    Borkiewicz, Olaf
    Chapman, Karena
    Lapidus, Saul
    Ren, Yang
    Wiaderek, Kamila
    Xu, Wenqian
    Yakovenko, Andrey
    Zhang, Xiaoyi
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2018, 74 : A378 - A378