Ordered mesoporous polyaniline film as a new matrix for enzyme immobilization and biosensor construction

被引:51
|
作者
Xu, Qin
Zhu, Jun-Jie [1 ]
Hu, Xiao-Ya
机构
[1] Nanjing Univ, Dept Chem, Key Lab Analyt Chem Life Sci MOE, Nanjing 210093, Peoples R China
[2] Yangzhou Univ, Coll Chem & Chem Engn, Yangzhou 225002, Peoples R China
基金
中国国家自然科学基金;
关键词
mesoporous; ordered; lyotropic liquid crystalline; biosensor;
D O I
10.1016/j.aca.2007.06.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ordered mesoporous polyaniline film has been fabricated by electrodepositing from the hexagonal lyotropic liquid crystalline (LCC). Horseradish peroxidase (HRP), as a symbol biomolecule, was successfully immobilized on the film to construct a new kind of hydrogen peroxide biosensor. The biosensor combined the advantages of the good conductivity of polyaniline and the higher surface area of the ordered mesoporous film. Polyaniline could be served as a wire to relay electron between HRP and the electrode. The high surface area of the film supplied more sites for HRP immobilization, therefore increased the catalytic activity of the biosensor. The ordered mesoporous character of the film increased the rate of mass transport, which resulted in the improvement of sensor response and linearity. The biosensor displayed excellent electrocatalytic response to the detection of H2O2 in a concentration range from 1.0 mu M to 2.0 mM with a detection limit of 0.63 mu M. Good reproducibility, stability, high precision, wide linearity and low detection limit were assessed for the biosensor. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:151 / 156
页数:6
相关论文
共 50 条
  • [41] Amperometric glucose biosensor based on a triangular silver nanoprisms/chitosan composite film as immobilization matrix
    Shi, Wentao
    Ma, Zhanfang
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (03): : 1098 - 1103
  • [42] Amperometric glucose biosensor based on a gold nanorods/cellulose acetate composite film as immobilization matrix
    Ren, Xiangling
    Chen, Dong
    Meng, Xianwei
    Tang, Fangqiong
    Du, Aiming
    Zhang, Lin
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 72 (02) : 188 - 192
  • [43] Amperometric hydrogen peroxide biosensor with silica sol-gel/chitosan film as immobilization matrix
    Miao, Y
    Tan, SN
    ANALYTICA CHIMICA ACTA, 2001, 437 (01) : 87 - 93
  • [44] Development of amperometric glucose biosensor through immobilizing enzyme in a Pt nanoparticles/mesoporous carbon matrix
    Yu, Jingjing
    Yu, Donglei
    Zhao, Tian
    Zeng, Baizhao
    TALANTA, 2008, 74 (05) : 1586 - 1591
  • [45] New strategy for enzyme stabilization involving molecular evolution and immobilization in mesoporous materials
    Takahashi, Haruo
    Miyazaki-Imamura, Chie
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U1037 - U1037
  • [46] New strategies for enzyme stabilization involving molecular evolution and immobilization in mesoporous materials
    Takahashi, Haruo
    Miyazaki-Imamura, Chie
    E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2005, 3 : 207 - 212
  • [47] RETENTION OF ENZYME BY ELECTROPOLYMERIZED FILM, A NEW APPROACH TO DEVELOPMENT OF A HYPOXANTHINE BIOSENSOR
    NGUYEN, AL
    LUONG, JHT
    YACYNYCH, AM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 200 : 10 - BIOT
  • [48] RETENTION OF ENZYME BY ELECTROPOLYMERIZED FILM - A NEW APPROACH IN DEVELOPING A HYPOXANTHINE BIOSENSOR
    NGUYEN, AL
    LUONG, JHT
    YACYNYCH, AM
    BIOTECHNOLOGY AND BIOENGINEERING, 1991, 37 (08) : 729 - 735
  • [49] Development of amperometric biosensor for glucose based on a novel attractive enzyme immobilization matrix: Calcium carbonate nanoparticles
    Shan, Dan
    Zhu, Mingjuan
    Xue, Huaiguo
    Cosnier, Serge
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (08): : 1612 - 1617
  • [50] In situ electropolymerized polyaniline-polyacrylonitrile composite film for the construction of a polyphenol oxidase-based biosensor
    Xue, H
    Shen, Z
    Zheng, H
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2002, 32 (11) : 1265 - 1268