Identifying Faulty Feeder for Single-Phase High Impedance Fault in Resonant Grounding Distribution System

被引:3
|
作者
Tang, Tao [1 ]
Huang, Chun [2 ]
Li, Zhenxing [3 ]
Yuan, Xiuguang [4 ]
机构
[1] Changsha Univ Sci & Technol, Coll Elect & Informat Engn, Changsha 410114, Hunan, Peoples R China
[2] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
[3] Sanxia Univ, Coll Elect Engn & New Energy, Yichang 443002, Hubei, Peoples R China
[4] Qingdao Power Supply Co, State Grid Shandong Elect Power Co, Qingdao 266000, Shandong, Peoples R China
关键词
faulty feeder identification; single-phase to ground; high impedance fault (HIF); resonant grounding distribution system (RGDS); NETWORKS;
D O I
10.3390/en12040598
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The identification of faulty feeder for single-phase high impedance faults (HIFs), especially in resonant grounding distribution system (RGDS), has always been a challenge, and existing faulty feeder identification techniques for HIFs suffer from some drawbacks. For this problem, the fault transient characteristic of single-phase HIF is analyzed and a faulty feeder identification method for HIF is proposed. The analysis shows that the transient zero-sequence current of each feeder is seen as a linear relationship between bus transient zero-sequence voltage and bus transient zero-sequence voltage derivative, and the coefficients are the reciprocal of transition resistance and feeder own capacitance, respectively, in both the over-damping state and the under-damping state. In order to estimate transition resistance and capacitance of each feeder, a least squares algorithm is utilized. The estimated transition resistance of a healthy feeder is infinite theoretically, and is a huge value practically. However, the estimated transition resistance of faulty feeder is approximately equal to actual fault resistance value, and it is far less than the set threshold. According to the above significant difference, the faulty feeder can be identified. The efficiency of the proposed method for the single-phase HIF in RGDS is verified by simulation results and experimental results that are based on RTDS.
引用
下载
收藏
页数:15
相关论文
共 50 条
  • [21] Locating Method of Single-phase Grounding Fault in Small Current Grounding System Based on Distribution Automation
    Zhou, Jun
    Cao, Kezheng
    MECHATRONICS AND INDUSTRIAL INFORMATICS, PTS 1-4, 2013, 321-324 : 1423 - 1428
  • [22] Faulty Feeder Identification and Fault Area Localization in Resonant Grounding System Based on Wavelet Packet and Bayesian Classifier
    Jingwen Chen
    Enliang Chu
    Yingchun Li
    Baoji Yun
    Hongshe Dang
    Yali Yang
    Journal of Modern Power Systems and Clean Energy, 2020, 8 (04) : 760 - 767
  • [23] Faulty Feeder Identification and Fault Area Localization in Resonant Grounding System Based on Wavelet Packet and Bayesian Classifier
    Chen J.
    Chu E.
    Li Y.
    Yun B.
    Dang H.
    Yang Y.
    Dang, Hongshe (danghs@sust.edu.cn), 1600, State Grid Electric Power Research Institute (08): : 760 - 767
  • [24] Faulty Feeder Identification and Fault Area Localization in Resonant Grounding System Based on Wavelet Packet and Bayesian Classifier
    Chen, Jingwen
    Chu, Enliang
    Li, Yingchun
    Yun, Baoji
    Dang, Hongshe
    Yang, Yali
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2020, 8 (04) : 760 - 767
  • [25] Influence of System Single-phase Grounding Fault on Load Loss of Grounding Transformer
    Chen L.
    Xian R.
    Li F.
    Xie T.
    Zhang B.
    Zhao Y.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (11): : 3941 - 3948
  • [26] A new method of single-phase grounding fault protection for a resonant grounding distribution network based on unbalanced overvoltage dynamic suppression
    Liu Z.
    Zeng X.
    Yu K.
    Liu S.
    Li L.
    Xu P.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (08): : 41 - 49
  • [27] Faulty Feeder Detection of Single-Phase Earthed Fault Using Dominant Transient Frequency Admittance
    Zhang, Xinhui
    Xu, Bingyin
    Wei, Peiyu
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 3561 - 3566
  • [28] Faulty Feeder Detection Based on Grey Correlation Degree of Adaptive Frequency Band in Resonant Grounding Distribution System
    Wang, Yanwen
    Cao, Jiyuan
    Hu, Zhiming
    Han, Xueqian
    Zhou, Xuan
    SUSTAINABILITY, 2023, 15 (10)
  • [29] A faulty line detection method for single phase-to-ground fault in resonant grounding system with CTs reversely connected
    Wang, Yizhao
    Liu, Jian
    Zhang, Zhihua
    Zheng, Tianyue
    Ren, Shuangxue
    Chen, Jieyu
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 147
  • [30] Identification of Feeder with Single-Phase Ground Fault
    Fedotov, Aleksander
    Vagapov, Georgii
    Abdullin, Linar
    2019 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2019,